27 resultados para Art 28 N° 7 Código de Comercio
em Publishing Network for Geoscientific
Resumo:
We present a study on the protozooplankton >5 µm and copepods larger than 50 µm at a series of contrasting stations across the Southern Indian Ocean (SIO). Numerically, over 80% of the copepod community across the transect was less than 650 µm in size, dominated by nauplii, and smaller copepods, while 80% of the biomass (as mg C/m**3) was larger than 1300 µm in body length. Predation by the carnivorous copepod Corycaeus sp. was estimated to be able to remove up to 2% /d of the copepods <1000 µm in size. By the help of grazing models we estimated that primary producers were mainly grazed upon by ciliates and heterotrophic dinoflagellates (40-80% /d combined) in temperate waters but appendicularians became increasingly important in the tropical waters grazing about 40% of the biomass per day. Despite their high abundance and biomass, copepods contributed less than 20% of the grazing at most stations. Secondary production was low (carbon specific egg production <0.14 /d) but typical for food limited oligotrophic oceans.
Resumo:
The chemical composition of surface associated metabolites of two Fucus species (Fucus vesiculosus and Fucus serratus) was analysed by means of gas chromatography-mass spectrometry (GC-MS) to describe temporal patterns in chemical surface composition. Method: The two perennial brown macroalgae F. vesiculosus and F. serratus were sampled monthly at Bülk, outer Kiel Fjord, Germany (54°27'21 N / 10°11'57 E) over an entire year (August 2012 - July 2013). Per month and species six non-fertile Fucus individuals were collected from mixed stands at a depth of 0.5 m under mid water level. For surface extraction approx. 50 g of the upper 5-10 cm apical thalli tips were cut off per species. The surface extraction of Fucus was performed according to the protocol of de Nys and co-workers (1998) with minor modifications (see Rickert et al. 2015). GC/EI-MS measurements were performed with a Waters GCT premier (Waters, Manchester, UK) coupled to an Agilent 6890N GC equipped with a DB-5 ms 30 m column (0.25 mm internal diameter, 0.25 mM film thickness, Agilent, USA). The inlet temperature was maintained at 250°C and samples were injected in split 10 mode. He carrier gas flow was adjusted to 1 ml min-1. Alkanes were used for referencing of retention times. For further details (GC-MS sample preparation and analysis) see the related publication (Rickert et al. submitted to PLOS ONE).