758 resultados para 1.1 Angstrom Resolution


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Time control is essential for the reconstruction of geological processes. We use a combination of relative and absolute methods to establish the chronology and related paleoclimatic processes for Late Neogene lacustrine sediment from the Ptolemais Basin, northern Greece. We determined changes in magnetic polarity and correlated them to the global magnetic polarity time scale, which again is calibrated by radiometric methods, to provide a low-resolution age model for the Upper Miocene to Lower Pliocene (7 - 3 Ma). Sedimentary successions show rhythmic alterations of lignites, clays, and marls. Using photospetrometry we measured this variability at 1-cm resolution, and correlated the pattern to known changes in earth's orbital parameters, namely to eccentricity and precession. For 230-m long borehole KAP-107 from the Amynteon Sub-Basin we obtained a high-resolution age model that spans 2 myr from 5.1 to 3.1 Ma, with age control points at insolation maxima (20-kyr resolution). We recommend using photospectrometry as reliable tool to establish orbital-based chronologies and to reconstruct paleoclimate variability at high resolution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pore water and turnover rates were determined for surface sediment cores obtained in 2009 and 2010. The pore water was extracted with Rhizons (Rhizon CSS: length 5 cm, pore diameter 0.15 µm; Rhizosphere Research Products, Wageningen, Netherlands) in 1 cm-resolution and immediately fixed in 5% zinc acetate (ZnAc) solution for sulfate, and sulfide analyses. The samples were diluted, filtered and the concentrations measured with non-suppressed anion exchange chromatography (Waters IC-Pak anion exchange column, waters 430 conductivity detector). The total sulfide concentrations (H2S + HS- + S**2-) were determined using the diamine complexation method (doi:10.4319/lo.1969.14.3.0454). Samples for dissolved inorganic carbon (DIC) and alkalinity measurements were preserved by adding 2 µl saturated mercury chloride (HgCl2) solution and stored headspace-free in gas-tight glass vials. DIC and alkalinity were measured using the flow injection method (detector VWR scientific model 1054) (doi:10.4319/lo.1992.37.5.1113). Dissolved sulfide was eliminated prior to the DIC measurement by adding 0.5 M molybdate solution (doi:10.4319/lo.1995.40.5.1011). Nutrient subsamples (10 - 15 ml) were stored at - 20 °C prior to concentration measurements with a Skalar Continuous-Flow Analyzer (doi:10.1002/9783527613984).