40 resultados para Primary Years Programme (PYP)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Knowledge of the long-term history of the perennial ice is an important issue that has eluded study because the Cenozoic core material needed has been unavailable until the recent Arctic Coring Expedition (ACEX). Detrital Fe oxide mineral grains analyzed by microprobe from the last 14 Ma (164 m) of the ACEX composite core on the Lomonosov Ridge were matched to circum-Arctic sources with the same mineral and 12-element composition. These precise source determinations and estimates of drift rates were used to determine that these sand grains could not be rafted to the ACEX core site in less than a year. Thus the perennial ice cover has existed since 14 Ma except for the unlikely rapid return to seasonal ice between the average sampling interval of about 0.17 Ma. Both North America and Russia contributed significant Fe grains to the ACEX core during the last 14 Ma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Material and data were collected at 41 sites in the subpolar North Atlantic Ocean between Scotland and Newfoundland, during the RRS CharlesDarwin CD159 cruise in July 2004 (McCave, 2005). Sites were selected to reflect the major inputs of water that becomes the North Atlantic Deep Water (NADW); the Iceland-Scotland Overflow Water (ISOW), the Denmark Strait Overflow Water (DSOW) and the Labrador Sea Water (LSW). Areas cored were the south Iceland Rise, SE Greenland slope/rise and Eirik Drift, and the Labrador margin. A total of 29 box cores, 19 piston cores, 6 kasten cores, 9 short gravity cores and 20 CTD casts as well as 28 surface water samples were collected during the cruise. Here we present sediment core-top sample ages. The cores were sampled at 1 or 0.5 cm intervals and we used the top 1 or 2 cm, depending on availability of foraminifera in the samples. Sediment samples were disaggregated on an end-over-end wheel, wet sieved at >63 um, and dry sieved to 63-150 and >150 um. Accelerator Mass Spectrometer (AMS) radiocarbon dating was done for each core top based on between 900-1600 monospecific planktonic foraminifera (Globigerina bulloides or Neogloboquadrina pachyderma (sinistral)). All dates were of modern or late Holocene age except site RAPID-08-5B (9806 ± 38 uncorrected 14C years BP) and site RAPID-14-10B (11543 ± 40 uncorrected 14C years BP). The >150 um fraction was split until approximately 300 foraminifera remained and counted for number of lithic grains, benthic foraminifera, planktonic foraminifera and foraminifera fragments. In all but the shallowest sample (Greenland rise, 761m water depth) benthic foraminifera constituted less than 2% of the total >150 um fraction of the sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first Air Chemistry Observatory at the German Antarctic station Georg von Neumayer (GvN) was operated for 10 years from 1982 to 1991. The focus of the established observational programme was on characterizing the physical properties and chemical composition of the aerosol, as well as on monitoring the changing trace gas composition of the background atmosphere, especially concerning greenhouse gases. The observatory was designed by the Institut für Umweltphysik, University of Heidelberg (UHEIIUP). The experiments were installed inside the bivouac lodge, mounted on a sledge and put upon a snow hill to prevent snow accumulation during blizzards. All experiments were under daily control and daily performance protocols were documented. A ventilated stainless steel inlet stack (total height about 3-4 m above the snow surface) with a 50% aerodynamic cut-off diameter around 7-10 µm at wind velocities between 4-10 m/s supplied all experiments with ambient air. Contamination free sampling was realized by several means: (i) The Air Chemistry Observatory was situated in a clean air area about 1500 m south of GvN. Due to the fact that northern wind directions are very rare, contamination from the base can be excluded for most of the time. (ii) The power supply (20 kW) is provided by a cable from the main station, thus no fuel-driven generator is operated in the very vicinity. (iii) Contamination-free sampling is controlled by the permanently recorded wind velocity, wind direction and by condensation particle concentration. Contamination was indicated if one of the following criteria were given: Wind direction within a 330°-30° sector, wind velocity <2.2 m/s or >17.5 m/s, or condensation particle concentrations >2500/cm**3 during summer, >800/cm**3 during spring/autumn and >400/cm**3 during winter. If one or a definable combination of these criteria were given, high volume aerosol sampling and part of the trace gas sampling were interrupted. Starting at 1982 through 1991-01-14 surface ozone was measured with an electrochemical concentration cell (ECC). Surface ozone mixing ratio are given in ppbv = parts per 10**9 by volume. The averaging time corresponds to the given time intervals in the data sheet. The accuracy of the values are better than ±1 ppbv and the detection limit is around 1.0 ppbv. Aerosols were sampled on two Whatman 541 cellulose filters in series and analyzed by ion chromatography at the UHEI-IUP. Generally, the sampling period was seven days but could be up to two weeks on occasion. The air flow was around 100 m**3/h and typically 10000-20000 m**3 of ambient air was forced through the filters for one sample. Concentration values are given in nanogram (ng) per 1 m**3 air at standard pressure and temperature (1013 mbar, 273.16 K). Uncertainties of the values were approximately ±10% to ±15% for the main components MSA, chloride, nitrate, sulfate and sodium, and between ±20% and ±30% for the minor species bromide, ammonium, potassium, magnesium and calcium.