400 resultados para 12930-073


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sensitivity of the tropics to climate change, particularly the amplitude of glacial-to-interglacial changes in sea surface temperature (SST), is one of the great controversies in paleoclimatology. Here we reassess faunal estimates of ice age SSTs, focusing on the problem of no-analog planktonic foraminiferal assemblages in the equatorial oceans that confounds both classical transfer function and modern analog methods. A new calibration strategy developed here, which uses past variability of species to define robust faunal assemblages, solves the no-analog problem and reveals ice age cooling of 5° to 6°C in the equatorial current systems of the Atlantic and eastern Pacific Oceans. Classical transfer functions underestimated temperature changes in some areas of the tropical oceans because core-top assemblages misrepresented the ice age faunal assemblages. Our finding is consistent with some geochemical estimates and model predictions of greater ice age cooling in the tropics than was inferred by Climate: Long-Range Investigation, Mapping, and Prediction (CLIMAP) [1981] and thus may help to resolve a long-standing controversy. Our new foraminiferal transfer function suggests that such cooling was limited to the equatorial current systems, however, and supports CLIMAP's inference of stability of the subtropical gyre centers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the expeditions ARK-VII/1, ARK-VII/3 and ARK-Xl2 sediment cores were taken by "RV Polarstern" from the shelf and the fjords of East Greenland and the Greenland Sea. The magnetic susceptibility and heavy mineral were determined at 48 surface sediment samples from undisturbed box cores. The main objective of this study was the identification of source areas and transport processes of terrigenous sediments at the East Greenland continental margin. The results can be summarized as lollows: 1a) Magnetic susceptibility in the North Atlantic is useful to detect delivery regions of the material transported by currents. b) The magnetic susceptibility is controlled by the ferromagnetic particles of the silt fraction. c) There are four important source areas: . The ferromagnetic particles of the box core PS2644-2 are transported from the Iceland Archipelago. . The material from the Geiki-Plateau effects the magnetic susceptibility in the Scoresby Sund Basin. . The magnetic susceptibility in the shelf regions in the North are produced by material from the fjords. . The ferromagnetic particles in the Greenland Sea are derived from the Mid Atlantic Ridges in the east. d) It is possible to determine the rock type, which delivers the ferromagnetic material because of differences in magnetic susceptibility of different intensity. . The erosion of the basalts of the Geiki-Plateau and the basalts of the Mid Atlantic ridges produce the high magnetic susceptibility in the south. . The magnetic susceptibility on the shelf in the north are probably produced by erosionproducts of the gneises of East Greenland. (2a) Heavy mineral assemblages show a significant difference between material transported by the Transpolar Drift from the Eurasian shelf regions (amphiboles, clinopyroxene, orthopyroxene) and material derived from East Greenland (garnets and opaque minerals). Transport via ice is dominant. b) lt is also possible to show different petrographic provenances (volcanic and metamorphic provenances). These associations verify the source areas. c) The information of heavy mineral composition gives no more detailed hint on the rock type or rock formation in the source area, due to mixing processes, large area of investigation and the sample quantity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyzed hydrographic data from the northwestern Weddell Sea continental shelf of the three austral winters 1989, 1997, and 2006 and two summers following the last winter cruise. During summer a thermal front exists at ~64° S separating cold southern waters from warm northern waters that have similar characteristics as the deep waters of the central basin of the Bransfield Strait. In winter, the whole continental shelf exhibits southern characteristics with high Neon (Ne) concentrations, indicating a significant input of glacial melt water. The comparison of the winter data from the shallow shelf off the tip of the Antarctic Peninsula, spanning a period of 17 yr, shows a salinity decrease of 0.09 for the whole water column, which has a residence time of <1 yr. We interpret this freshening as being caused by a combination of reduced salt input due to a southward sea ice retreat and higher precipitation during the late 20th century on the western Weddell Sea continental shelf. However, less salinification might also result from a delicate interplay between enhanced salt input due to sea ice formation in coastal areas formerly occupied by Larsen A and B ice shelves and increased Larsen C ice loss.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The chemical composition of surface associated metabolites of two Fucus species (Fucus vesiculosus and Fucus serratus) was analysed by means of gas chromatography-mass spectrometry (GC-MS) to describe temporal patterns in chemical surface composition. Method: The two perennial brown macroalgae F. vesiculosus and F. serratus were sampled monthly at Bülk, outer Kiel Fjord, Germany (54°27'21 N / 10°11'57 E) over an entire year (August 2012 - July 2013). Per month and species six non-fertile Fucus individuals were collected from mixed stands at a depth of 0.5 m under mid water level. For surface extraction approx. 50 g of the upper 5-10 cm apical thalli tips were cut off per species. The surface extraction of Fucus was performed according to the protocol of de Nys and co-workers (1998) with minor modifications (see Rickert et al. 2015). GC/EI-MS measurements were performed with a Waters GCT premier (Waters, Manchester, UK) coupled to an Agilent 6890N GC equipped with a DB-5 ms 30 m column (0.25 mm internal diameter, 0.25 mM film thickness, Agilent, USA). The inlet temperature was maintained at 250°C and samples were injected in split 10 mode. He carrier gas flow was adjusted to 1 ml min-1. Alkanes were used for referencing of retention times. For further details (GC-MS sample preparation and analysis) see the related publication (Rickert et al. submitted to PLOS ONE).