2 resultados para moisture sensors

em University of Connecticut - USA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lack of linearity and sensitivity, oxygen dependence, biofouling and tissue inflammation hinder the development of implantable biosensors for continuous monitoring of glucose. Herein, we report the development of stacked outer membranes based on LBL/PVA hydrogels that improve sensor sensitivity, linearity, oxygen independence and counter biofouling and inflammation. While the inner LBL membrane affords tunable diffusivity, the outer PVA is capable of releasing anti-inflammatory drugs/tissue response modifying agents to counter acute and chronic inflammation, and to induce neo-angiogenesis at the implant site. Sensors were fabricated by immobilizing GOx enzyme on top of 50 μm platinum wires, followed by deposition of stacked LBL/PVA hydrogel membranes. The response of the sensors at 0.7V to various glucose concentrations was studied. Michelis-Menten analysis was performed to quantify sensor performance in terms of linearity and oxygen dependence. The interplay between sensor performance and inward glucose diffusivity was elucidated using (i) various LBL membranes and (ii) various freeze-thaw (FT) cycles of PVA. Incorporation of LBL/PVA stacked membranes resulted in an 8 fold increase in sensor linearity and a 9 fold decrease in oxygen dependence compared to controls. The enhancement in the sensor performance is attributed to (i) the oxygen storing capability of PVA hydrogel due to the formation of hydrophobic domains during its freezing/ thawing employed for its physical crosslinking and (ii) regulation of glucose flux by the inner LBL membrane. Such membranes offer significant advantages over presently available outer membranes in lieu of (i) their ability to control inflammation, (ii) their modulus that closely matches that of subcutaneous human tissue, (iii) non-necessity of reactive chemical crosslinking agents, (iv) tunable sensitivity and (v) supplemental storage of oxygen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The skinned portions of baseball and softball infields vary widely with respect to soil texture, applied amendments and conditioners, and water management. No studies have been reported that quantify the effects of these varying construction and maintenance practices on the playability of the skinned portions of infields. In Connecticut, USA, skinned infield plots were constructed from five different soils (silt loam, loam, coarse sandy loam, loamy sand, loamy coarse sand) and amended with four rates of calcined clay (0, 4.9, 9.8, 19.6 kg m–2) to determine the effects on surface hardness, traction, and ball-to-surface friction (static and dynamic) at varying soil moisture contents (10, 14, and 18%). Bulk density, saturated hydraulic conductivity, and shear strength of the different soil–calcined clay rate combinations were determined. Increasing the rate of calcined clay decreased bulk density and shear strengths, and increased saturated hydraulic conductivity. Surface hardness increased more with coarse-textured soils and increasing calcined clay rate, but decreased more with fine-textured soils and increasing soil moisture. Increasing the calcined clay rate resulted in decreases in ball-to-surface static friction across all soils and decreased dynamic friction with the fine-textured soils. Increases in soil moisture increased friction in all soils. The fine-textured soils had greater traction than the sandy soils, but no consistent calcined clay or moisture effects on traction were observed. Shear strength of the soils was highly correlated with traction and friction. The results suggest that differences in skinned infield soils are quantifiable, which could lead to the development of playing surface standards.