5 resultados para cellulose membranes
em University of Connecticut - USA
Resumo:
Lack of linearity and sensitivity, oxygen dependence, biofouling and tissue inflammation hinder the development of implantable biosensors for continuous monitoring of glucose. Herein, we report the development of stacked outer membranes based on LBL/PVA hydrogels that improve sensor sensitivity, linearity, oxygen independence and counter biofouling and inflammation. While the inner LBL membrane affords tunable diffusivity, the outer PVA is capable of releasing anti-inflammatory drugs/tissue response modifying agents to counter acute and chronic inflammation, and to induce neo-angiogenesis at the implant site. Sensors were fabricated by immobilizing GOx enzyme on top of 50 μm platinum wires, followed by deposition of stacked LBL/PVA hydrogel membranes. The response of the sensors at 0.7V to various glucose concentrations was studied. Michelis-Menten analysis was performed to quantify sensor performance in terms of linearity and oxygen dependence. The interplay between sensor performance and inward glucose diffusivity was elucidated using (i) various LBL membranes and (ii) various freeze-thaw (FT) cycles of PVA. Incorporation of LBL/PVA stacked membranes resulted in an 8 fold increase in sensor linearity and a 9 fold decrease in oxygen dependence compared to controls. The enhancement in the sensor performance is attributed to (i) the oxygen storing capability of PVA hydrogel due to the formation of hydrophobic domains during its freezing/ thawing employed for its physical crosslinking and (ii) regulation of glucose flux by the inner LBL membrane. Such membranes offer significant advantages over presently available outer membranes in lieu of (i) their ability to control inflammation, (ii) their modulus that closely matches that of subcutaneous human tissue, (iii) non-necessity of reactive chemical crosslinking agents, (iv) tunable sensitivity and (v) supplemental storage of oxygen.
Resumo:
Anion exchange membranes (AEMs) are a potential method for determining the plant available N status of soils; however, their capacity for use with turfgrass has not been researched extensively. The main objective of this experiment was to determine the relationship between soil nitrate desorbed from AEMs and growth response and quality of turfgrass managed as a residential lawn. Two field experiments were conducted with a bluegrass-ryegrass-fescue mixture receiving four rates of N fertilizer (0, 98, 196, and 392 kg N ha(-1) yr(-1)) with clippings returned or removed. The soils at the two sites were a Paxton fine sandy loam (coarse-loamy, mixed, active, mesic Oxyaquic Dystrudepts) and a variant of a Hinckley gravelly sandy loam (sandy-skeletal, mixed, mesic Typic Udorthents). Anion exchange membranes were inserted into plots and exchanged weekly during the growing seasons of 1998 and 1999. Nitrate-N was desorbed from AEMs and quantified. As N fertilization rates increased, desorbed NO3-N increased. The relationship of desorbed NO3-N from AEMs to clipping yield and turfgrass quality was characterized using quadratic response plateau (QRP) and Cate-Nelson models (C-Ns). Critical levels of desorbed NO3-N ranged from 0.86 to 8.0 microgram cm(-2) d(-1) for relative dry matter yield (DMY) and from 2.3 to 12 microgram cm(-2) d(-1) for turfgrass quality depending upon experimental treatment. Anion exchange membranes show promise of indicating the critical levels of soil NO3-N desorbed from AEMs necessary to achieve maximum turfgrass quality and yield without overapplication of N.
Resumo:
Nutrient leaching studies are expensive and require expertise in water collection and analyses. Less expensive or easier methods that estimate leaching losses would be desirable. The objective of this study was to determine if anion-exchange membranes (AEMs) and reflectance meters could predict nitrate (NO3-N) leaching losses from a cool-season lawn turf. A two-year field study used an established 90% Kentucky bluegrass (Poa pratensis L.)-10% creeping red fescue (Festuca rubra L.) turf that received 0 to 98 kg N ha-1 month-1, from May through November. Soil monolith lysimeters collected leachate that was analyzed for NO3-N concentration. Soil NO3-N was estimated with AEMs. Spectral reflectance measurements of the turf were obtained with chlorophyll and chroma meters. No significant (p > 0.05) increase in percolate flow-weighted NO3-N concentration (FWC) or mass loss occurred when AEM desorbed soil NO3-N was below 0.84 µg cm-2 d-1. A linear increase in FWC and mass loss (p < 0.0001) occurred, however, when AEM soil NO3-N was above this value. The maximum contaminant level (MCL) for drinking water (10 mg L-1 NO3-N) was reached with an AEM soil NO3-N value of 1.6 µg cm-2 d-1. Maximum meter readings were obtained when AEM soil NO3 N reached or exceeded 2.3 µg cm-2 d-1. As chlorophyll index and hue angle (greenness) increased, there was an increased probability of exceeding the NO3-N MCL. These data suggest that AEMs and reflectance meters can serve as tools to predict NO3-N leaching losses from cool-season lawn turf, and to provide objective guides for N fertilization.
Resumo:
Conductive membranes were prepared by magnetic alignment of graphite-coated iron nanoparticles (GCINs) in a polyisobutylene (PIB) matrix, which was cast onto an interdigitated surface electrode. Toluene and tetrahydrofuran (THF) were used as solvents for the casting solution. Different molecular weights of PIB and solutions with concentrations ranging from 0.05- to 50-wt% were explored to optimize the mechanical and physical properties of the membrane. The amount of GCINs used in the membranes ranged from 0.1- to 2.5-wt%, and a sonicator was used to disperse the particles in the membrane. Sedimentation and surfactant studies were conducted to investigate the dispersion of GCINs in solutions. Progresses were made to find an optimal combination of various parameters in order to attain thin homogenous membranes for fast response.
Resumo:
Ideal nitrogen (N) management for turfgrass supplies sufficient N for high-quality turf without increasing N leaching losses. A greenhouse study was conducted during two 27-week periods to determine if in situ anion exchange membranes (AEMs) could predict nitrate (NO3-N) leaching from a Kentucky bluegrass (Poa pratensis) turf grown on intact soil columns. Treatments consisted of 16 rates of N fertilizer application, from 0 to 98 kg N ha-1 mo-1. Percolate water was collected weekly and analysed for NO3-N. Mean flow-weighted NO3-N concentration and cumulative mass in percolate were exponentially related (pseudo-R2=0.995 and 0.994, respectively) to AEM desorbed soil NO3-N, with a percolate concentration below 10 mg NO3-N L-1 corresponding to an AEM soil NO3-N value of 2.9 micro g cm-2 d-1. Apparent N recovery by turf ranged from 28 to 40% of applied N, with a maximum corresponding to 4.7 micro g cm-2 d-1 AEM soil NO3-N. Turf colour, growth, and chlorophyll index increased with increasing AEM soil NO3-N, but these increases occurred at the expense of increases in NO3-N leaching losses. These results suggest that AEMs might serve as a tool for predicting NO3-N leaching losses from turf.