3 resultados para whole blood samples
em DigitalCommons@The Texas Medical Center
Resumo:
In a phase I clinical trial, six multiple myeloma patients, who were non-responsive to conventional therapy and were scheduled for bone marrow transplantation, received Holmium-166 ($\sp{166}$Ho) labeled to a bone seeking agent, DOTMP (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethylene-phosphonic acid), for the purpose of bone marrow ablation. The specific aims of my research within this protocol were to evaluate the toxicity and efficacy of $\sp{166}$Ho DOTMP by quantifying the in vivo pharmacokinetics and radiation dosimetry, and by correlating these results to the biologic response observed. The reproducibility of pharmacokinetics from multiple injections of $\sp{166}$Ho DOTMP administered to these myeloma patients was demonstrated from both blood and whole body retention. The skeletal concentration of $\sp{166}$Ho DOTMP was heterogenous in all six patients: high in the ribs, pelvis, and lumbar vertebrae regions, and relatively low in the femurs, arms, and head.^ A novel technique was developed to calculate the radiation dose to the bone marrow in each skeletal ROI, and was applied to all six $\sp{166}$Ho DOTMP patients. Radiation dose estimates for the bone marrow calculated using the standard MIRD "S" factors were compared with the average values derived from the heterogenous distribution of activity in the skeleton (i.e., the regional technique). The results from the two techniques were significantly different; the average of the dose estimates from the regional technique were typically 30% greater. Furthermore, the regional technique provided a range of radiation doses for the entire marrow volume, while the MIRD "S" factors only provided a single value. Dose volume histogram analysis of data from the regional technique indicated a range of dose estimates that varied by a factor of 10 between the high dose and low dose regions. Finally, the observed clinical response of cells and abnormal proteins measured in bone marrow aspirates and peripheral blood samples were compared with radiation dose estimates for the bone marrow calculated from the standard and regional technique. The results showed the regional technique values correlated more closely to several clinical response parameters. (Abstract shortened by UMI.) ^
Resumo:
The mutagenicity study of the urinary metabolites of 2-aminonaphthalene was conducted to determine whether differences in metabolism between different acetylator phenotypes could account for a proposed mechanism of bladder carcinogenesis. This required the use of fast and slow acetylator rabbits with phenotypic similarities to humans. In the absence of available slow acetylators, it was necessary to inhibit fast acetylators. The proposed mechanism was that slow acetylators were at greater potential risk of bladder carcinogenesis due to low rates of acetylation, a detoxification mechanism for certain aromatic amines. The alternate metabolic pathway will be hydroxylation. The fast acetylators were proposed to exhibit lower risk of bladder carcinogenicity as a result of higher acetylation rates and less mutagenic metabolites.^ This hypothesis was approached by determining from in vitro mutagenicity assays with Salmonella typhimurium strains TA98 and TA100 whether different metabolites were mutagenic. The acetylation rate of each rabbit and a suitable method of acetylation inhibition were determined through oral exposure to dapsone and the acetylation inhibitor, K-p-aminosalicylic acid. Residues of dapsone and its acetylated metabolite were extracted from blood samples and analyzed by ultra-violet spectrometry using standard curves for each metabolite. The urine samples were concentrated on XAD-2 resin and analyzed both as whole urine concentrates and as isolated metabolites from spots on high performance thin layer chromatography plates. The major isolated spots were identified and quantified through extraction and analysis by high performance liquid chromatography when possible.^ Acetylation rate determination and inhibition were successfully demonstrated in rabbits. Significant mutagenicity was noted for several critical metabolites. None of the mutagenic metabolites were detected in higher concentration in the inhibited acetylators and thus, no clear relationship of metabolite concentration to bladder carcinogenesis was evident for the compounds analyzed. There was some evidence that the inhibitor may have affected critical enzyme systems other than acetylation alone. This would account for the lower concentrations of mutagenic hydroxylated compounds observed. ^
Resumo:
Accurate screening for anemia at Red Cross blood donor clinics is essential to maintain a safe national blood supply. Despite the importance of identifying anemia correctly by measurement of hemoglobin or hematocrit (hemoglobin/hematocrit) there is no consensus regarding the efficacy of the current two stage screening method which uses the Readacrit$\sp{\rm tm}$ microhematocrit in conjunction with copper sulfate.^ A cross-sectional study was implemented in which hemoglobin/hematocrit was measured, with the present method and four new devices, on 504 prospective blood donors at a Canadian Red Cross permanent blood donor clinic in London, Canada. Concurrently gathered, venous and capillary blood samples were tested by each device and compared to Coulter S IV$\sp{\rm tm}$ determined venous standard readings. Instrument hemoglobin/hematocrit means were statistically calibrated to the standard ones in order to appraise systematic deviations from the standard. Classification analysis was employed to assess concordance between each instrument and the standard when classifying prospective donors as anemic or non-anemic. This was done both when each instrument was used alone (single stage) and when copper sulfate was used as a preliminary screen (two stage) and simulated over a range of anemia prevalences. The Hemoximeter$\sp{\rm tm}$ and Compur M1000$\sp{\rm tm}$ devices had the highest correlations of hemoglobin measurements with the standard ones for both capillary (n.s.) and venous blood (p $<$.05). Analysis of variance (anova) also showed them to be the most accurate (p $<$.05), as did both single and two stage classification analysis, therefore, they are both recommended. There was a smaller difference between instruments for two stage than for single stage screening; therefore instrument choice is less crucial for the former. The present method was adequate for two stage screening as tested but simulations showed that it would discriminate poorly in populations with a higher prevalence of anemia. The Stat-crit and Readacrit, which measure hematocrit, became less accurate at crucial low hematocrit levels. In light of this finding and the introduction of new, effective and easy to use hemoglobin measuring instruments, the continued use of hematocrit as a surrogate for hemoglobin, is not recommended. ^