5 resultados para very low energy beam transfer
em DigitalCommons@The Texas Medical Center
Resumo:
BACKGROUND: There is a continuous debate regarding the best bottle nipple to be used to enhance the bottle-feeding performance of a preterm infant. Aim: To verify that feeding performance can be improved by using the bottle nipple with the physical characteristics that enhance infants' sucking skills. METHODS: Ten "healthy" VLBW infants (941+/-273 g) were recruited. Feeding performance was monitored at two time periods, when taking 1-2 and 6-8 oral feedings/d. At each time and within 24 h, performance was monitored using three different bottle nipples offered in a randomized order. Rate of milk transfer (ml/min) was the primary outcome measure. The sucking skills monitored comprised stage of sucking, suction amplitude, and duration of the generated negative intraoral suction pressure. RESULTS: At both times, infants demonstrated a similar rate of milk transfer among all three nipples. However, the stage of sucking, suction amplitude, and duration of the generated suction were significantly different between nipples at 1-2, but not 6-8 oral feedings/d.CONCLUSION: We did not identify a particular bottle nipple that enhanced bottle feeding in healthy VLBW infants. Based on the notion that afferent sensory feedback may allow infants to adapt to changing conditions, we speculate that infants can modify their sucking skills in order to maintain a rate of milk transfer that is appropriate with the level of suck-swallow-breathe coordination achieved at a particular time. Therefore, it is proposed that caretakers should be more concerned over monitoring the coordination of suck-swallow-breathe than over the selection of bottle nipples.
Resumo:
OBJECTIVE: (1) To compare maternal characteristics and psychological stress profile among African-American, Caucasian and Hispanic mothers who delivered very low birthweight infants. (2) To investigate associations between psychosocial factors, frequency of milk expression, skin-to-skin holding (STS), and lactation performance, defined as maternal drive to express milk and milk volume. STUDY DESIGN: Self-reported psychological questionnaires were given every 2 weeks after delivery over 10 weeks. Milk expression frequency, STS, and socioeconomic variables were collected. RESULT: Infant birthweight, education, and milk expression frequency differed between groups. Trait anxiety, depression and parental stress in a neonatal intensive care unit (PSS:NICU) were similar. African-American and Caucasian mothers reported the lowest scores in state anxiety and social desirability, respectively. Maternal drive to express milk, measured by maintenance of milk expression, correlated negatively with parental role alteration (subset of PSS:NICU) and positively with infant birthweight and STS. Milk volume correlated negatively with depression and positively with milk expression frequency and STS. CONCLUSION: Differences between groups were observed for certain psychosocial factors. The response bias to self-reported questionnaires between groups may not provide an accurate profile of maternal psychosocial profile. With different factors correlating with maintenance of milk expression and milk volume, lactation performance can be best enhanced with a multi-faceted intervention program, incorporating parental involvement in infant care, close awareness and management of maternal mental health, and encouragement for frequent milk expression and STS.
Resumo:
PURPOSE: In United States, the percentage of Extremely Low Birth Weight (ELBW) born for year 2006 was 0.8% (approximately 32,000 babies) & Very Low Birth Weight (VLBW) 1.48% (1). ELBW babies account for nearly half (49%) of the infant mortality for United States. Very Low birth weight infants are at a significant risk for high mortality and morbidity due to their multi system involvement and predisposition to lung prematurity and impaired immune function. One of the common causes cited is Vitamin A deficiency (2, 3).The purpose of this study is to look at published literature on Vitamin A supplementation in very low birth weight (VLBW) infants. ^ RESEARCH DESIGN: Systematic review of literature of published articles meeting the pre-defined criteria. ^ PROCEDURE: Studies included in this review were those which looked at very low birth weight infants defined as birth weight<1500gms. All experimental studies were reviewed. Studies looking at the effect of Vitamin A supplementation in comparison with a placebo or by itself in varying dosing regimens as an intervention were reviewed. Vitamin A deficiency and its manifestations were of interest. We used key words such as "very low birth weight", "mortality", "Vitamin A", "retinol" and "supplementation" in our search. ^ RISKS & POTENTIAL BENEFITS: We do not see any potential risks associated with this study. The potential benefit is recommendation for future studies based on the review of literature available currently. ^ IMPORTANCE OF KNOWLEDGE THAT MAY REASONABLY BE EXPECTED TO RESULT: The systematic review of literature of all experimental studies in VLBW infants showed uniform correlation of parenteral Vitamin A dosing and high plasma concentrations achieved. The recommended dosage for use is 5000 IU 3 times/week given intramuscularly for 4 weeks to prevent CLD. Higher doses have not shown benefit, with a potential for toxicity, while lower doses are inadequate. There is no role of use of Vitamin A in closure of patent ductus arteriosus & reducing mortality. However, it is important to state that the number of studies done so far is limited with small sample sizes. There is a need in the future for experimental studies to ascertain the role of Vitamin A to improve outcomes in VLBW. Atleast, one more RCT should be conducted using the dosage recommended above to make this a standard practice.^
Resumo:
Measurement of the absorbed dose from ionizing radiation in medical applications is an essential component to providing safe and reproducible patient care. There are a wide variety of tools available for measuring radiation dose; this work focuses on the characterization of two common, solid-state dosimeters in medical applications: thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD). There were two main objectives to this work. The first objective was to evaluate the energy dependence of TLD and OSLD for non-reference measurement conditions in a radiotherapy environment. The second objective was to fully characterize the OSLD nanoDot in a CT environment, and to provide validated calibration procedures for CT dose measurement using OSLD. Current protocols for dose measurement using TLD and OSLD generally assume a constant photon energy spectrum within a nominal beam energy regardless of measurement location, tissue composition, or changes in beam parameters. Variations in the energy spectrum of therapeutic photon beams may impact the response of TLD and OSLD and could thereby result in an incorrect measure of dose unless these differences are accounted for. In this work, we used a Monte Carlo based model to simulate variations in the photon energy spectra of a Varian 6MV beam; then evaluated the impact of the perturbations in energy spectra on the response of both TLD and OSLD using Burlin Cavity Theory. Energy response correction factors were determined for a range of conditions and compared to measured correction factors with good agreement. When using OSLD for dose measurement in a diagnostic imaging environment, photon energy spectra are often referenced to a therapy-energy or orthovoltage photon beam – commonly 250kVp, Co-60, or even 6MV, where the spectra are substantially different. Appropriate calibration techniques specifically for the OSLD nanoDot in a CT environment have not been presented in the literature; furthermore the dependence of the energy response of the calibration energy has not been emphasized. The results of this work include detailed calibration procedures for CT dosimetry using OSLD, and a full characterization of this dosimetry system in a low-dose, low-energy setting.
Resumo:
HANES 1 detailed sample data were used to operationalize a definition of health in the absence of disease and to describe and compare the characteristics of the normal (healthy) group versus an abnormal (unhealthy) group.^ Parallel screening gave a 3.8 percent prevalence proportion of physical health, with a female:male ratio of 2:1 and younger ages in the healthy group. Statistically significant Mantel-Haenszel gender-age-adjusted odds ratios (MHOR) were estimated among abnormal non-migrants (1.53), skilled workers/unemployed (1.76), annual family incomes of less than $10,000 (1.56), having ever smoked (1.58), and started smoking before 18 years of age (1.58). Significant MHOR were also found for abnormals for health promoting measures: non-iodized salt use (1.94), needed dental care (1.91); and for fair to poor perceived health (4.28), perceiving health problems (2.52), and low energy level (1.68). Significant protective effects for much to moderate recreational exercise (MHOR 0.42) and very active to moderate non-recreational activity (MHOR 0.49) were also obtained. Covariance analysis additive models detected statistically significant higher mean values for abnormals than normals for serum magnesium, hemoglobin, hematocrit, urinary creatinine, and systolic and diastolic blood pressures, and lower values for abnormals than normals for serum iron. No difference was detected for serum cholesterol. Significant non-additive joint effects were found for body mass index.^ The results suggest positive physical health can be measured with cross-sectional survey data. Gender differentials, and associations between ecologic, socioeconomic, hazardous risk factors, health promoting activities and physical health are in general agreement with published findings on studies of morbidity. Longitudinal prospective studies are suggested to establish the direction of the associations and to enhance present knowledge of health and its promoting factors. ^