4 resultados para strain rate effects

em DigitalCommons@The Texas Medical Center


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially-available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. This work measures the overall quantitative accuracy of the PEM Flex system, and determines the contributions of error due to count rate effects, attenuation and scatter. Materials and Methods: Gelatin phantoms were designed to simulate breasts of different sizes (4 – 12 cm thick) with varying uniform background activity concentration (0.007 – 0.5 μCi/cc), cysts and lesions (2:1, 5:1, 10:1 lesion-to-background ratios). The overall error was calculated from ROI measurements in the phantoms with a clinically relevant background activity concentration (0.065 μCi/cc). The error due to count rate effects was determined by comparing the overall error at multiple background activity concentrations to the error at 0.007 μCi/cc. A point source and cold gelatin phantoms were used to assess the errors due to attenuation and scatter. The maximum pixel values in gelatin and in air were compared to determine the effect of attenuation. Scatter was evaluated by comparing the sum of all pixel values in gelatin and in air. Results: The overall error in the background was found to be negative in phantoms of all thicknesses, with the exception of the 4-cm thick phantoms (0%±7%), and it increased with thickness (-34%±6% for the 12-cm phantoms). All lesions exhibited large negative error (-22% for the 2:1 lesions in the 4-cm phantom) which increased with thickness and with lesion-to-background ratio (-85% for the 10:1 lesions in the 12-cm phantoms). The error due to count rate in phantoms with 0.065 μCi/cc background was negative (-23%±6% for 4-cm thickness) and decreased with thickness (-7%±7% for 12 cm). Attenuation was a substantial source of negative error and increased with thickness (-51%±10% to -77% ±4% in 4 to 12 cm phantoms, respectively). Scatter contributed a relatively constant amount of positive error (+23%±11%) for all thicknesses. Conclusion: Applying corrections for count rate, attenuation and scatter will be essential for the PEM Flex Solo II to be able to produce quantitatively accurate images.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effect of circadian variation on susceptibility to the chemical induction of cancer was assessed utilizing the mouse pulmonary adenoma bioassay. Different groups of male A/Jax mice (standardized for rhythm analysis with light from 0600-1800 and darkness from 1800-0600) each received a single timed i.p. injection of urethan (Bioassay I: 0.25, 0.5 or 1.0 mg/g body weight; Bioassay II: 0.75, 1.0, 1.25 mg/g body weight; Bioassay III: 1.0 mg/g body weight) at the following times, 0100, 0500, 0900, 1300, 1700 or 2100. Mice were sacrificed 16 weeks after treatment. The tumorigenic effect of urethan on the lungs (lung surface pulmonary adenomas) was assessed. In addition, mortality, body weight changes and the anesthetic effect of urethan were determined. The rhythmic pattern of DNA synthesis in the lung and the comparative rhythmic pattern in the liver were assessed using a tritiated thymidine incorporation assay.^ In the first adenoma bioassay, the lung tumorigenic response in mice given the highest dose of urethan exhibited a 12-hour rhythm with a major peak in tumor yield at 0100 and a secondary peak at 1300; reduced yields occurred at 0500-0900 and 2100. The second adenoma bioassay, studied at a 6-month seasonal divergence in time from the first study showed a peak at 1300 but not at 0100. The mice from the third adenoma bioassay, studied at an 11-month seasonal divergence in time from the 2nd study showed an increase in tumor yield during the rest cycle (0900-1700).^ This study found a definite suggestion of a low amplitude rhythm in susceptibility to urethan induced effects. The acute toxic and pharmacological effects correlated to exhibit a maximal effect during dark hours (activity span). This rhythmicity might be explained by an alteration in the amplitude of hepatic metabolism. The chronic carcinogenic response exhibited an opposite pattern. Urethan induced tumor response was greater during daylight hours (rest cycle). This correlated with the slight elevation in DNA synthetic activity found in the lung and liver which might be responsible for the increase in carcinogenic response. (Abstract shortened with permission of author.) ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

CHARACTERIZATION OF THE COUNT RATE PERFORMANCE AND EVALUATION OF THE EFFECTS OF HIGH COUNT RATES ON MODERN GAMMA CAMERAS Michael Stephen Silosky, B.S. Supervisory Professor: S. Cheenu Kappadath, Ph.D. Evaluation of count rate performance (CRP) is an integral component of gamma camera quality assurance and measurement of system dead time (τ) is important for quantitative SPECT. The CRP of three modern gamma cameras was characterized using established methods (Decay and Dual Source) under a variety of experimental conditions. For the Decay method, input count rate was plotted against observed count rate and fit to the paralyzable detector model (PDM) to estimate τ (Rates method). A novel expression for observed counts as a function of measurement time interval was derived and the observed counts were fit to this expression to estimate τ (Counts method). Correlation and Bland-Altman analysis were performed to assess agreement in estimates of τ between methods. The dependencies of τ on energy window definition and incident energy spectrum were characterized. The Dual Source method was also used to estimate τ and its agreement with the Decay method under identical conditions and the effects of total activity and the ratio of source activities were investigated. Additionally, the effects of count rate on several performance metrics were evaluated. The CRP curves for each system agreed with the PDM at low count rates but deviated substantially at high count rates. Estimates of τ for the paralyzable portion of the CRP curves using the Rates and Counts methods were highly correlated (r=0.999) but with a small (~6%) difference. No significant difference was observed between the highly correlated estimates of τ using the Decay or Dual Source methods under identical experimental conditions (r=0.996). Estimates of τ increased as a power-law function with decreasing ratio of counts in the photopeak to the total counts and linearly with decreasing spectral effective energy. Dual Source method estimates of τ varied as a quadratic with the ratio of the single source to combined source activities and linearly with total activity used across a large range. Image uniformity, spatial resolution, and energy resolution degraded linearly with count rate and image distorting effects were observed. Guidelines for CRP testing and a possible method for the correction of count rate losses for clinical images have been proposed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Maine implemented a hospital rate-setting program in 1984 at approximately the same time as Medicare started the Prospective Payment System (PPS). This study examines the effectiveness of the program in controlling cost over the period 1984-1989. Hospital costs in Maine are compared to costs in 36 non rate-setting states and 11 other rate-setting states. Changes in cost per equivalent admission, adjusted patient day, per capita, admissions, and length of stay are described and analyzed using multivariate techniques. A number of supply and demand variables which were expected to influence costs independently of rate-setting were controlled for in the study. Results indicate the program was effective in containing costs measured in terms of cost per adjusted patient day. However, this was not true for the other two cost variables. The average length of stay increased during the period in Maine hospitals indicating an association with rate-setting. Several supply variables, especially the number of beds per 1,000 population were strongly associated with the cost and use of hospitals. ^