2 resultados para slowly varying envelope approximation

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human endogenous retrovirus K (HERV-K) env gene encodes envelope protein comprising surface (SU) and transmembrane (TM) domains. Having shown the exclusive expression of SU in human breast cancer and the stimulation of SU-specific immune responses in patients with breast cancer, our research here confirmed and extended the data by investigating the expression of HERV-K TM envelope domain and the induction of specific immune responses against TM in breast cancer patients. We found HERV-K TM mRNA and protein expression only in human breast cancer cells but not in normal controls. The specific immune responses against TM domain were induced in mice determined by enzyme-linked immunosorbent assay (ELISA) and IFN-γ enzyme-linked immunosorbent spot (ELISPOT) assay. Furthermore, ELISA detected higher titers of anti-HERV-K TM Env IgG antibodies in sera of breast cancer patients. In addition, the magnitude of the anti-HERV TM B cell response was correlated with the disease stage. Peripheral blood mononuclear cells (PBMCs) before and after in vitro stimulation (IVS) with HERV-K TM from patients with breast cancer as well as healthy controls were tested for T cell responses against HERV-K TM domain by ELISPOT assay. Breast cancer patients (n=21) had stronger HERV-K TM-specific cellular responses than healthy controls (n=12) (P < 0.05). These findings suggest, for the first time, that HERV-K TM expression was enhanced in human breast cancer cells and was able to induce specific B cell and T cell immune responses in breast cancer patients. This study provides support for HERV-K TM as a promising source of antigen for anti-tumor immunotherapy, prevention, diagnosis, and prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^