2 resultados para slots
em DigitalCommons@The Texas Medical Center
Resumo:
This exploratory study assesses the utility of substance abuse treatment as a strategy for preventing human immunodeficiency virus (HIV) transmission among injecting drug users (IDUs). Data analyzed in this study were collected in San Antonio, TX, 1989 through 1995 using both qualitative and quantitative methods. Qualitative data included ethnographic interviews with 234 active IDUs; quantitative data included baseline risk assessments and HIV screening plus interviews follow-up interviews administered approximately six months later to 823 IDUs participating in a Federally-funded AIDS community outreach demonstration project.^ Findings that have particularly important implications for substance abuse treatment as an HIV prevention strategy for IDUs are listed below. (1) IDUs who wanted treatment were significantly more likely to be daily heroin users. (2) IDUs who want treatment were significantly more likely to have been to treatment previously. (3) IDUs who wanted treatment at baseline reported significantly higher levels of HIV risk than IDUs who did not want treatment. (4) IDUs who went to treatment between their baseline and follow-up interviews reported significantly higher levels of HIV risk at baseline than IDUs who did not go to treatment. (5) IDUs who went to treatment between their baseline and follow-up interviews reported significantly greater decreases in injection-related HIV risk behaviors. (6) IDUs who went to treatment reported significantly greater decreases in sexual HIV risk behaviors than IDUs who did not go to treatment.^ This study also noted a number of factors that may limit the effectiveness of substance abuse treatment in reducing HIV risk among IDUs. Findings suggest that the impact of methadone maintenance on HIV risk behaviors among opioid dependent IDUs may be limited by the negative manner in which it is perceived by IDUs as well as other elements of society. One consequence of the negative perception of methadone maintenance held by many elements of society may be an unwillingness to provide public funding for an adequate number of methadone maintenance slots. Thus many IDUs who would be willing to enter methadone maintenance are unable to enter it and many IDUs who do enter it are forced to drop out prematurely. ^
Resumo:
This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters (Landauer, Glenwood, IL) was designed and built. The phantom has a single channel capable of accepting all 192Ir HDR brachytherapy sources in current clinical use in the United States. Irradiations were performed with an 192Ir HDR source to determine correction factors for linearity with dose, dose rate, and the combined effect of irradiation energy and phantom construction. The uncertainties introduced by source positioning in the phantom and timer resolution limitations were also investigated. It was found that the linearity correction factor was where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters under 60Co irradiation. There was no significant dose rate effect. Separate energy+block correction factors were determined for both models of 192Ir sources currently in clinical use and these vendor-specific correction factors differed by almost 2.6%. For Nucletron sources, this correction factor was 1.026±0.004 (99% Confidence Interval) and for Varian sources it was 1.000±0.007 (99% CI). Reasonable deviations in source positioning within the phantom and the limited resolution of the source timer had insignificant effects on the ability to measure dose. Overall measurement uncertainty of the system was estimated to be ±2.5% for both Nucletron and Varian source audits (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a formal RPC audit program. Trial audits of eight participating institutions resulted in an average RPC-to-institution dose ratio of 1.000 with a standard deviation of 0.011.