2 resultados para salt-assisted effect

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Congenital Adrenal Hyperplasia (CAH), due to 21-Hydroxylase deficiency, has an estimated incidence of 1:15,000 births and can result in death, salt-wasting crisis or impaired growth. It has been proposed that early diagnosis and treatment of infants detected from newborn screening for CAH will decrease the incidence of mortality and morbidity in the affected population. The Texas Department of Health (TDH) began mandatory screening for CAH in June, 1989 and Texas is one of fourteen states to provide neonatal screening for the disorder.^ The purpose of this study was to describe the cost and effect of screening for CAH in Texas during 1994 and to compare cases first detected by screen and first detected clinically between January 1, 1990 and December 31, 1994. This study used a longitudinal descriptive research design. The data was secondary and previously collected by the Texas Department of Health. Along with the descriptive study, an economic analysis was done. The cost of the program was defined, measured and valued for four phases of screening: specimen collection, specimen testing, follow-up and diagnostic evaluation.^ There were 103 infants with Classical CAH diagnosed during the study and 71 of the cases had the more serious Salt-Wasting form of the disease. Of the infants diagnosed with Classical CAH, 60% of the cases were first detected by screen and 40% were first detected because of clinical findings before the screening results were returned. The base case cost of adding newborn screening to an existing program (excluding the cost of specimen collection) was $357,989 for 100,000 infants. The cost per case of Classical CAH diagnosed, based on the number of infants first detected by screen in 1994, was \$126,892. There were 42 infants diagnosed with the more benign Nonclassical form of the disease. When these cases were included in the total, the cost per infant to diagnose Congenital Adrenal/Hyperplasia was $87,848. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intracavitary brachytherapy (ICB) combined with external beam irradiation for treatment of cervical cancer is highly successful in achieving local control. The M.D. Anderson Cancer Center employs Fletcher Suit Delclos (FSD) applicators. FSD applicators contain shields to limit dose to critical structures. Dosimetric evaluation of ICB implants is limited to assessing dose at reference points. These points serve as surrogates for treatment intensity and critical structure dose. Several studies have mentioned that the ICRU38 reference points inadequately characterize the dose distribution. Also, the ovoid shields are rarely considered in dosimetry. ^ The goal of this dissertation was to ascertain the influence of the ovoid shields on patient dose distributions. Monte Carlo dosimetry (MCD) was applied to patient computed tomography(CT) scans. These data were analyzed to determine the effect of the shields on dose to standard reference points and the bladder and rectum. The hypothesis of this work is that the ICRU38 bladder and rectal points computed conventionally are not clinically acceptable surrogates for the maximum dose points as determined by MCD. ^ MCD was applied to the tandem and ovoids. The FSD ovoids and tandem were modeled in a single input file that allowed dose to be calculated for any patient. Dose difference surface histograms(DDSH) were computed for the bladder and rectum. Reference point doses were compared between shielded and unshielded ovoids, and a commercial treatment planning system. ^ The results of this work showed the tandem tip screw caused a 33% reduction in dose. The ovoid shields reduced the dose by a maximum of 48.9%. DDSHs revealed on average 5% of the bladder surface area was spared 53 cGy and 5% of the rectal surface area was spared 195 cGy. The ovoid shields on average reduced the dose by 18% for the bladder point and 25% for the rectal point. The Student's t-test revealed the ICRU38 bladder and rectal points do not predict the maximum dose for these organs. ^ It is concluded that modeling the tandem and ovoid internal structures is necessary for accurate dose calculations, the bladder shielding segments may not be necessary, and that the ICRU38 bladder point is irrelevant. ^