9 resultados para relative humidity

em DigitalCommons@The Texas Medical Center


Relevância:

60.00% 60.00%

Publicador:

Resumo:

On a global basis rotaviruses are the most important agents involved in childhood diarrhea. In developing countries they account for 6% of all diarrheas and 20% of all diarrhea related deaths of children under 5 years of age, with over 1 billion episodes and over 4 million deaths annually. Given the disease burden, there is a need for better understanding the risk factors involved in rotavirus disease, to identify areas of intervention. In order to provide this information, two areas were developed: a review of the literature, examining the causal evidence for rotavirus diarrhea and a case comparison study. The case comparison study analyzed two areas: identifying climate factors and, identifying environmental and behavioral risk factors. The literature review showed that few analytical studies have identified specific risk factors such as home environment, and a winter seasonal trend for temperate areas, but in key areas evidence is contradictory. The case comparison study for climate factors demonstrated that seasonality occurs in a tropical country like Venezuela and that a complex interplay between weather conditions contribute to the seasonal pattern. A positive association between rain fall (OR 4.1); dew point (OR 2.3) and temperature differential during the day (OR 1.4) and, an inverse association with temperature (OR 0.5) and relative humidity (OR 0.8) was found. This information is useful in understanding the seasonal pattern of rotavirus and for planning health care needs. The second analysis demonstrated that environmental variables such as crowding (OR 14.3), contact with someone with an infectious disease (OR 4.9) and animal ownership (OR 2.3) were important. Restricting the analysis to animal owners demonstrated that living In a rural settling (OR 13.8), defecating in inappropriate places (OR 7.2), crowding(4.2) and indoor animals (4.0) are of importance. Behavioral variables identified were: lack of breast feeding (OR 4.0) and visiting when someone was sick (OR 3.4). Biological and demographic variables of importance were: age, with a dose response relationship; undernurishment (OR 11.3) and household per capita monthly income less than US $ 16.30 (OR 8.5). Using a diarrhea compeer group we found that, although some of the previous variables were of importance, no major differences were found. These findings are important in identifying paths for prevention and further research. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The airliner cabin environment and its effects on occupant health have not been fully characterized. This dissertation is: (1) A review of airliner environmental control systems (ECSs) that modulate the ventilation, temperature, relative humidity (RH), and barometric pressure (PB) of the cabin environment---variables related to occupant comfort and health. (2) A review and assessment of the methods and findings of key cabin air quality (CAQ) investigations. Several significant deficiencies impede the drawing of inferences about CAQ, e.g., lack of detail about investigative methods, differences in methods between investigations, limited assessment of CAQ variables, small sample sizes, and technological deficiencies of data collection. (3) A comprehensive evaluation of the methods used in the subsequent NIOSH-FAA Airliner CAQ Exposure Assessment Feasibility Study (STUDY) in which this author participated. A number of problems were identified which limit the usefulness of the data. (4) An analysis of the reliable 10-flight STUDY data. Univariate and multivariate methods applied to CO2 (a surrogate for air contaminants), temperature, RH, and PB, in association with percent passenger load, ventilation system, flight duration, airliner body type, and measurement location within the cabin, revealed neither the measured values nor their variability exceeded established health-based exposure limits. Regression analyses suggest CO2, temperature, and RH were affected by percent passenger load. In-flight measurements of CO2 and RH were relatively independent of ventilation system type or flight duration. Cabin temperature was associated with percent passenger load, ventilation system type, and flight duration. (5) A synthesis of the implications of the airliner ECS and cabin O2 environment on occupant health. A model was developed to predict consequences of the airliner cabin pressure altitude 8,000 ft limit and resulting model-estimated PO2 on cardiopulmonary status. Based on the PB, altitude, and environmental data derived from the 10 STUDY flights, the predicted PaO2 of adults with COPD, or elderly adults with or without COPD, breathing ambient cabin air could be < 55 mm Hg (SaO2 < 88%). Reduction in cabin PB found in the STUDY flights could aggravate various medical conditions and require the use of in-flight supplemental O2. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Outdoor environmental risk factors for asthma have been extensively researched, even though the majority of a person's daily activity occurs indoors. There is limited evidence linking personal exposure concentrations of ozone, pollen, mold, temperature, and humidity to childhood asthma. ^ The current study consisted of a secondary, more complex analysis of the data from the Houston Air Toxics and Asthma in Children (ATAC) Study to further investigate the association of personal ozone exposure on asthma outcome variability among middle school children with asthma. The ATAC Study primarily investigated the association between selected oxygenated air toxics and indicators of asthma variability (PEFR, FEV1, asthma symptoms, and rescue medication usage) among 30 labile and persistent Houston middle-school children with diagnosed asthma. This panel study used a repeated measurements design of four separate 10-day sampling periods that extended over a 20 month period. The secondary analysis included aggregate regression models that were constructed with two different estimates of ozone exposure (daily maximum hourly outdoor concentration and daily maximum hourly personal exposure), with three different estimates of personal environmental temperature and humidity exposures (daily average, intraday difference, and interday difference), and for thee different time periods [same day of exposure (lag 0), one day after initial exposure (lag 1), and two days after initial exposure (lag 2)]. ^ Overall, the models using daily maximum hourly personal ozone exposures in combination with intraday and interday personal temperature and humidity differences produced more significant plausible associations than models using daily maximum hourly personal ozone exposures with personal average temperature and humidity exposures. Significant associations were identified between daily maximum hourly personal ozone exposure and clinical indicators of asthma variability. The increasing effect on rescue medication usage from daily maximum hourly personal ozone exposure were identified as soon as the same day of exposure (lag 0; p=0.0072), and the same effects were delayed until the second next day (lag 2; p= 0.0026). The increasing effect on asthma symptoms were identified on the second next day after initial exposure (lag 2; p= 0.0024). There was a consistent inverse relationship between personal relative humidity exposure and indicators of asthma variability. Decreasing effects on daily FEV1 variability from personal relative humidity exposure were identified on the same day of exposure (lag 0; p= 0.034), increasing effects on morning PEFR were identified on the next day after initial exposure (lag 1; p= 0.0001), and decreasing effects on overnight PEFR variability were identified on the second next day after the initial exposure (lag 2; p= 0.007). With the conclusion of this research, there are opportunities for future similar studies in the preventive management of asthma in children living in high-ozone areas.^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To explore the natural trajectory of core body temperature (CBT) and cortisol (CORT) circadian rhythms in mechanically ventilated intensive care unit (MV ICU) patients. ^ Design: Prospective, observational, time-series pilot study. ^ Setting: Medical-surgical and pulmonary ICUs in a tertiary care hospital. ^ Sample: Nine (F = 3, M = 6) adults who were mechanically ventilated within 12 hrs of ICU admission with mean ± SD age of 65.2 ± 14 years old. ^ Measurements: Core body temperature and environmental measures of light, sound, temperature, and relative humidity were logged in 1-min intervals. Hourly urine specimens and 2-hr interval blood specimens were collected for up to 7 consecutive days for CORT assay. Mechanical ventilation days, ICU length of stay, and ICU mortality were documented. Acute Physiology and Chronic Health Evaluation (APACHE) II scores were computed for each study day. The data of each biologic and environmental variable were analyzed using single cosinor analysis of 24-hr serial segments. One patient did not complete the study because mortality occurred within 8 hrs of enrollment. Nine ICU patients completed the study in 1.6 to 7.0 days. ^ Results: No normal circadian rhythm pattern was found when the cosinor-derived parameters of amplitude (one-half the peak-trough variability) and acrophase (peak time) were compared with cosinor-derived parameter reference ranges of healthy, diurnally active humans, although 83% of patient-day CBT segments showed statistically significant (p ≤ .05) and biologically meaningful (R2≥ 0.30) 24-hr rhythms with abnormal cosinor parameters. Cosinor parameters of the environmental temporal profiles showed 27% of light, 76% of ambient temperature, and 78% of relative humidity serial segments had a significant and meaningful 24-hr diurnal pattern. Average daily light intensity varied from 34 to 187 lx with a maximum light exposure of 1877 lx. No sound measurement segment had a statistically significant cosine pattern, and numerous 1-minute interval peaks ≥ 60 dB occurred around the clock. Average daily ambient temperature and relative humidity varied from 19 to 24°C and from 25% to 61%, respectively. There was no statistically significant association between CBT or clinical outcomes and cosinor-derived parameters of the environmental variables. Circadian rhythms of urine and plasma CORT were deferred for later analysis. ^ Conclusions: The natural trajectory of the CBT circadian rhythm in MV ICU patients demonstrated persistent cosinor parameter alteration, even when a significant and meaningful 24-hr rhythm was present. The ICU environmental measures showed erratic light and sound exposures. Room temperature and relative humidity data produced the highest rate of significant and meaningful diurnal 24-hr patterns. Additional research is needed to clarify relations among the CBT biomarker of the circadian clock and environmental variables of MV ICU patients. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Indoor Air Quality (IAQ) can have significant implications for health, productivity, job performance, and operating cost. Professional experience in the field of indoor air quality suggests that high expectations (better than nationally established standards) (American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE)) of workplace indoor air quality lead to increase air quality complaints. To determine whether there is a positive association between expectations and indoor air quality complaints, a one-time descriptive and analytical cross-sectional pilot study was conducted. Area Safety Liaisons (n = 330) at University of Texas Health Science Center – Houston were asked to answer a questionnaire regarding their expectations of four workplace indoor air quality indicators i.e., (temperature, relative humidity, carbon dioxide, and carbon monoxide) and if they experienced and reported indoor air quality problems. A chi-square test for independence was used to evaluate associations among the variables of interest. The response rate was 54% (n = 177). Results did not show significant associations between expectation and indoor air quality. However, a greater proportion of Area Safety Liaisons who expected indoor air quality indicators to be better than the established standard experienced greater indoor air quality problems. Similarly, a slightly higher proportion of Area Liaisons who expected indoor air quality indicators to be better than the standard reported greater indoor air quality complaints. ^ The findings indicated that a greater proportion of Area Safety Liaisons with high expectations (conditions that are beyond what is considered normal and acceptable by ASHRAE) experienced greater indoor air quality discomfort. This result suggests a positive association between high expectations and experienced and reported indoor air quality complaints. Future studies may be able to address whether the frequency of complaints and resulting investigations can be reduced through information and education about what are acceptable conditions.^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the indoor environment of two different types of dental practices regarding VOCs, PM2.5, and ultrafine particulate concentrations and examine the relationship between specific dental activities and contaminant levels. Method: The indoor environments of two selected dental settings (private practice and community health center) will were assessed in regards to VOCs, PM 2.5, and ultrafine particulate concentrations, as well as other indoor air quality parameters (CO2, CO, temperature, and relative humidity). The sampling duration was four working days for each dental practice. Continuous monitoring and integrated sampling methods were used and number of occupants, frequency, type, and duration of dental procedures or activities recorded. Measurements were compared to indoor air quality standards and guidelines. Results: The private practice had higher CO2, CO, and most VOC concentrations than the community health center, but the community health center had higher PM2.5 and ultrafine PM concentrations. Concentrations of p-dichlorobenzene and PM2.5 exceeded some guidelines. Outdoor concentrations greatly influenced the indoor concentration. There were no significant differences in contaminant levels between the operatory and general area. Indoor concentrations during the working period were not always consistently higher than during the nonworking period. Peaks in particulate matter concentration occurred during root canal and composite procedures.^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study represents a secondary analysis of the merging of emergency room visits and daily ozone and PM2.5. Although the adverse health effects of ozone and fine particulate matter have been documented in the literature, evidence regarding the health risks of these two pollutants in Harris County, Texas, is limited. Harris County (Houston) has sufficiently unique characteristics that analysis of these relationships in this setting and with the ozone and industry issues in Houston is informative. The objective of this study was to investigate the association between the joint exposure to ozone and fine particulate matter, and emergency room diagnoses of chronic obstructive pulmonary disease and cardiovascular disease in Harris County, Texas, from 2004 to 2009, with zero and one day lags. ^ The study variables were daily emergency room visits for Harris County, Texas, from 2004 to 2009, temperature, relative humidity, east wind component, north wind component, ozone, and fine particulate matter. Information about each patient's age, race, and gender was also included. The two dichotomous outcomes were emergency room visits diagnoses for chronic obstructive pulmonary disease and cardiovascular disease. Estimates of ozone and PM2.5 were interpolated using kriging, in which estimates of the two pollutants were predicted from monitoring data for every case residence zip code for every day of the six years, over 3 million estimates (one of each pollutant for each case in the database). ^ Logistic regressions were conducted to estimate odds ratios of the two outcomes. Three analyses were conducted: one for all records, another for visits during the four months of April and September of 2005 and 2009, and a third one for visits from zip codes that are close to PM2.5 monitoring stations (east area of Harris County). The last two analyses were designed to investigate special temporal and spatial characteristics of the associations. ^ The dataset included all ER visits surveyed by Safety Net from 2004 to 2009, exceeding 3 million visits for all causes. There were 95,765 COPD and 96,596 CVD cases during this six year period. A 1-μg/m3 increase in PM2.5 on the same day was associated with a 1.0% increase in the odds of chronic obstructive pulmonary disease emergency room diagnoses, a 0.4% increase in the odds of cardiovascular disease emergency room diagnoses, and a 0.2% increase in the odds of cardiovascular disease emergency room diagnoses on the following day. A 1-ppb increase in ozone was associated with a 0.1% increase in the odds of chronic obstructive pulmonary disease emergency room diagnoses on the same day. These four percentages add up to 1.7% of ER visits. That is, over the period of six years, one unit increase for both ozone and PM2.5 (joint increase), resulted in about 55,286 (3,252,102 * 0.017) extra ER visits for CVD or COPD, or 9,214 extra ER visits per year. ^ After adjustment for age, race, gender, day of the week, temperature, relative humidity, east wind component, north wind component, and wind speed, there were statistically significant associations between emergency room chronic obstructive pulmonary disease diagnosis in Harris County, Texas, with joint exposure to ozone and fine particulate matter for the same day; and between emergency room cardiovascular disease diagnosis and exposure to PM2.5 of the same day and the previous day. ^ Despite the small association between the two air pollutants and the health outcomes, this study points to important findings. Namely, the need to identify reasons for the increase of CVD and COPD ER visits over the course of the project, the statistical association between humidity (or whatever other variables for which it may serve as a surrogate) and CVD and COPD cases, and the confirmatory finding that males and blacks have higher odds for the two outcomes, as consistent with other studies. ^ An important finding of this research suggests that the number and distribution of PM2.5 monitors in Harris County - although not evenly spaced geographically—are adequate to detect significant association between exposure and the two outcomes. In addition, this study points to other potential factors that contribute to the rising incidence rates of CVD and COPD ER visits in Harris County such as population increases, patient history, life style, and other pollutants. Finally, results of validation, using a subset of the data demonstrate the robustness of the models.^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^