2 resultados para red-light

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Standard treatment strategies for cancer patients include surgery, radiation therapy, and chemotherapy. Although these strategies have been proven effective, they also have associated limitations. An attractive and innovative approach that can be used alone or in combination with the above modalities is based on the systemic or topical administration of a nanomaterial-based photoactive compound. Interaction with light in the near infrared (NIR) region results in either emission of fluorescence, which can be used for photodetection, or absorption of light which results in phototherapy. Nanomaterials have the advantage of providing multi-functional and unique properties in a single device that cannot be readily acquired with conventional small molecular weight compounds. ^ In this study, three different novel nanocarrier systems were designed and evaluated in mediating photodetection and phototherapy in the NIR. The first compound synthesized was a dual-labeled magnetic resonance/optical imaging agent for sentinel lymph node mapping and biopsy. This dual-labeled agent combines the high resolution of magnetic resonance imaging with the highly sensitive detection of optical imaging. The second imaging agent was an activatable optical imaging agent used to monitor cathepsin B activity in vivo and to probe the degradation of poly(L-glutamic acid). This polymeric nanocarrier offers highly sensitive technique for the detection of enzymatic activity, with is not yet possible with small molecular weight compounds. The third agent was a C225-conjugated hollow nanoshell that is targeted to epidermal growth factor receptors. This targeting agent has been demonstrated to mediate photothermal therapy both in vitro and in vivo. ^ These nanocarrier systems are an invaluable tool for the detection of cancer and many other diseases. With improved targeted delivery of these agents, the ability to diagnose diseases will become more sensitive and more specific. Finally, when designed properly, these agents would allow concurrent diagnosis and treatment of patients of various diseases. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate screening for anemia at Red Cross blood donor clinics is essential to maintain a safe national blood supply. Despite the importance of identifying anemia correctly by measurement of hemoglobin or hematocrit (hemoglobin/hematocrit) there is no consensus regarding the efficacy of the current two stage screening method which uses the Readacrit$\sp{\rm tm}$ microhematocrit in conjunction with copper sulfate.^ A cross-sectional study was implemented in which hemoglobin/hematocrit was measured, with the present method and four new devices, on 504 prospective blood donors at a Canadian Red Cross permanent blood donor clinic in London, Canada. Concurrently gathered, venous and capillary blood samples were tested by each device and compared to Coulter S IV$\sp{\rm tm}$ determined venous standard readings. Instrument hemoglobin/hematocrit means were statistically calibrated to the standard ones in order to appraise systematic deviations from the standard. Classification analysis was employed to assess concordance between each instrument and the standard when classifying prospective donors as anemic or non-anemic. This was done both when each instrument was used alone (single stage) and when copper sulfate was used as a preliminary screen (two stage) and simulated over a range of anemia prevalences. The Hemoximeter$\sp{\rm tm}$ and Compur M1000$\sp{\rm tm}$ devices had the highest correlations of hemoglobin measurements with the standard ones for both capillary (n.s.) and venous blood (p $<$.05). Analysis of variance (anova) also showed them to be the most accurate (p $<$.05), as did both single and two stage classification analysis, therefore, they are both recommended. There was a smaller difference between instruments for two stage than for single stage screening; therefore instrument choice is less crucial for the former. The present method was adequate for two stage screening as tested but simulations showed that it would discriminate poorly in populations with a higher prevalence of anemia. The Stat-crit and Readacrit, which measure hematocrit, became less accurate at crucial low hematocrit levels. In light of this finding and the introduction of new, effective and easy to use hemoglobin measuring instruments, the continued use of hematocrit as a surrogate for hemoglobin, is not recommended. ^