4 resultados para quality assurance, higher education, policy, administrators, Ontario

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Commercial treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in the National Cancer Institute sponsored clinical trials administer radiation in doses that are clinically comparable to those of other participating institutions. To complement the effort of the RPC, an independent dose calculation tool needs to be developed that will enable a generic method to determine patient dose distributions in three dimensions and to perform retrospective analysis of radiation delivered to patients who enrolled in past clinical trials. Methods A multi-source model representing output for Varian 6 MV and 10 MV photon beams was developed and evaluated. The Monte Carlo algorithm, know as the Dose Planning Method (DPM), was used to perform the dose calculations. The dose calculations were compared to measurements made in a water phantom and in anthropomorphic phantoms. Intensity modulated radiation therapy and stereotactic body radiation therapy techniques were used with the anthropomorphic phantoms. Finally, past patient treatment plans were selected and recalculated using DPM and contrasted against a commercial dose calculation algorithm. Results The multi-source model was validated for the Varian 6 MV and 10 MV photon beams. The benchmark evaluations demonstrated the ability of the model to accurately calculate dose for the Varian 6 MV and the Varian 10 MV source models. The patient calculations proved that the model was reproducible in determining dose under similar conditions described by the benchmark tests. Conclusions The dose calculation tool that relied on a multi-source model approach and used the DPM code to calculate dose was developed, validated, and benchmarked for the Varian 6 MV and 10 MV photon beams. Several patient dose distributions were contrasted against a commercial algorithm to provide a proof of principal to use as an application in monitoring clinical trial activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. No Child Left Behind aimed to "improve the academic achievement of the disadvantaged." The primary research question considered how academic achievement of those from economic disadvantage compared to those not from disadvantage? ^ Economically disadvantaged students can potentially have added academic disadvantage. Research shows low academic achievement can potentially result in drug abuse, youth violence, and teen pregnancy. ^ Methods. To compare the student populations, measures included TAKS results and academic indicator data collected by the Texas Education Agency. ^ Results. T-test analyses showed a significant difference between the economically and non-economically disadvantaged student populations in meeting the TAKS passing standard, graduation, and preparation for higher education.^ Conclusions. The achievement gap between students remained as indicated by the Texas testing program. More research and time are needed to observe if the desired impact on those from economic disadvantage will be reflected by academic achievement data.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Public health surveillance programs for vaccine preventable diseases (VPD) need functional quality assurance (QA) in order to operate with high quality activities to prevent preventable communicable diseases from spreading in the community. Having a functional QA plan can assure the performance and quality of a program without putting excessive stress on the resources. A functional QA plan acts as a check on the quality of day-to-day activities performed by the VPD surveillance program while also providing data that would be useful for evaluating the program. This study developed a QA plan that involves collection, collation, analysis and reporting of information based on standardized (predetermined) formats and indicators as an integral part of routine work for the vaccine preventable disease surveillance program at the City of Houston Department of Health and Human Services. The QA plan also provides sampling and analysis plans for assessing various QA indicators, as well as recommendations to the Houston Department of Health and Humans Services for implementation of the QA plan. The QA plan developed for VPD surveillance in the City of Houston is intended to be a low cost system that could serve as a template for QA plans as part of other public health programs not only in the city or the nation, but could be adapted for use anywhere across the globe. Having a QA plan for VPD surveillance in the City of Houston would serve well for the funding agencies like the CDC by assuring that the resources are being expended efficiently, while achieving the real goal of positively impacting the health and lives of the recipient/target population. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) uses both on-site and remote reviews to credential institutions for participation in clinical trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as a replacement for TLD in the QA phantoms. A 10 cm diameter high-impact polystyrene spherical phantom was designed and constructed to hold an OSLD to study the angular response of the dosimeter under the simplest of circumstances for both coplanar and non-coplanar treatment deliveries. OSLD were irradiated in the spherical phantom, and the responses of the dosimeter from edge-on angles were normalized to the response when irradiated with the beam incident normally on the surface of the dosimeter. The average normalized response was used to establish an angular correction factor for 6 MV and 18 coplanar treatments, and for 6 MV non-coplanar treatments specific to CyberKnife. The RPC pelvic phantom dosimetry insert was modified to hold OSLD, in addition to the TLD, adjacent to the planes of film. Treatment plans of increasing angular beam delivery were developed, three in Pinnacle v9.0 (4-field box, IMRT, and VMAT) and one in Accuray’s MultiPlan v3.5.3 (CyberKnife). The plans were delivered to the pelvic phantom containing both TLD and OSLD in the target volume. The pelvic phantom was also sent to two institutions to be irradiated as trials, one delivering IMRT, and the other a CyberKnife treatment. For the IMRT deliveries and the two institution trials, the phantom also included film in the sagittal and coronal planes. The doses measured from the TLD and OSLD were calculated for each irradiation, and the angular correction factors established from the spherical phantom irradiations were applied to the OSLD dose. The ratio of the TLD dose to the angular corrected OSLD dose was calculated for each irradiation. The corrected OSLD dose was found to be within 1% of the TLD measured dose for all irradiations, with the exception of the in-house CyberKnife deliveries. The films were normalized to both TLD measured dose and the corrected OSLD dose. Dose profiles were obtained and gamma analysis was performed using a 7%/4 mm criteria, to compare the ability of the OSLD, when corrected for the angular dependence, to provide equivalent results to TLD. The results of this study indicate that the OSLD can effectively be used as a replacement for TLD in the RPC’s anthropomorphic QA phantoms for coplanar treatment deliveries when a correction is applied for the dosimeter’s angular dependence.