2 resultados para pulse therapy
em DigitalCommons@The Texas Medical Center
Resumo:
Patients who had started HAART (Highly Active Anti-Retroviral Treatment) under previous aggressive DHHS guidelines (1997) underwent a life-long continuous HAART that was associated with many short term as well as long term complications. Many interventions attempted to reduce those complications including intermittent treatment also called pulse therapy. Many studies were done to study the determinants of rate of fall in CD4 count after interruption as this data would help guide treatment interruptions. The data set used here was a part of a cohort study taking place at the Johns Hopkins AIDS service since January 1984, in which the data were collected both prospectively and retrospectively. The patients in this data set consisted of 47 patients receiving via pulse therapy with the aim of reducing the long-term complications. ^ The aim of this project was to study the impact of virologic and immunologic factors on the rate of CD4 loss after treatment interruption. The exposure variables under investigation included CD4 cell count and viral load at treatment initiation. The rates of change of CD4 cell count after treatment interruption was estimated from observed data using advanced longitudinal data analysis methods (i.e., linear mixed model). Using random effects accounted for repeated measures of CD4 per person after treatment interruption. The regression coefficient estimates from the model was then used to produce subject specific rates of CD4 change accounting for group trends in change. The exposure variables of interest were age, race, and gender, CD4 cell counts and HIV RNA levels at HAART initiation. ^ The rate of fall of CD4 count did not depend on CD4 cell count or viral load at initiation of treatment. Thus these factors may not be used to determine who can have a chance of successful treatment interruption. CD4 and viral load were again studied by t-tests and ANOVA test after grouping based on medians and quartiles to see any difference in means of rate of CD4 fall after interruption. There was no significant difference between the groups suggesting that there was no association between rate of fall of CD4 after treatment interruption and above mentioned exposure variables. ^
Resumo:
The current standard for temperature sensitive imaging using magnetic resonance (MR) is 2-D, spoiled, fast gradient-echo (fGRE) phase-difference imaging exploiting temperature dependent changes in the proton resonance frequency (PRF). The echo-time (TE) for optimal sensitivity is larger than the typical repetition time (TR) of an fGRE sequence. Since TE must be less than TR in the fGRE sequence, this limits the technique's achievable sensitivity, spatial, and temporal resolution. This adversely affects both accuracy and volume coverage of the measurements. Accurate measurement of the rapid temperature changes associated with pulsed thermal therapies, such as high-intensity focused ultrasound (FUS), at optimal temperature sensitivity requires faster acquisition times than those currently available. ^ Use of fast MR acquisition strategies, such as interleaved echo-planar and spiral imaging, can provide the necessary increase in temporal performance and sensitivity while maintaining adequate signal-to-noise and in-plane spatial resolution. This research explored the adaptation and optimization of several fast MR acquisition methods for thermal monitoring of pulsed FUS thermal therapy. Temperature sensitivity, phase-difference noise and phase-difference to phase-difference-to noise ratio for the different pulse sequences were evaluated under varying imaging parameters in an agar gel phantom to establish optimal sequence parameters for temperature monitoring. The temperature sensitivity coefficient of the gel phantom was measured, allowing quantitative temperature extrapolations. ^ Optimized fast sequences were compared based on the ability to accurately monitor temperature changes at the focus of a high-intensity focused ultrasound unit, volume coverage, and contrast-to-noise ratio in the temperature maps. Operating parameters, which minimize complex phase-difference measurement errors introduced by use of the fast-imaging methods, were established. ^