3 resultados para personality consistency
em DigitalCommons@The Texas Medical Center
Resumo:
Family preservation has been criticized for implementing programs that are not theoretically founded. One result of this circumstance is a lack of information regarding processes and outcomes of family preservation services. The knowledge base of family preservation is thus rather limited at present and will remain limited unless theory is consistently integrated within individual programs. A model for conceptualizing how theoretical consistency may be implemented within programs is presented and applied to family preservation. It is also necessary for programs to establish theoretical consistency before theoretical diversity, both within individual and across multiple programs, in order to advance the field in meaningful ways. A developmental cycle of knowledge generation is presented and applied to family preservation.
Resumo:
The study focused on the relationship between antisocial personality syndrome in boys ages 8-15 and parental alcohol/drug dependency. The population studied was case records of 101 boys coming to a private psychiatrist from 1966 through 1979. The boys were predominantly white and from middle to upper income families.^ A boy was determined to have antisocial personality syndrome if he exhibited antisocial behaviors in four or five major categories, did not exhibit a brain syndrome, and did not exhibit a thought disorder. The five major behavior categories were: (1) self-control (i.e., temper tantrums or hyperactivity), (2) behavior at home (i.e., disobedience or lying), (3) behavior at school (i.e., truancy or cheating), (4) behavior toward peers (i.e., bullying, fighting, or tattling), and (5) behavior against property (i.e., destructiveness or stealing). A boy was determined to be a control if he exhibited antisocial behaviors in two or less behavior categories.^ A parent was determined to have alcohol/drug dependency if s/he exhibited a score above the established threshold (1) for the MacAndrew Alcoholism Scale (28 or above), and (2) for the Holmes Alcoholism Scale (35 or above) which are used with the MMPI. A parent was classified not alcohol/drug dependent if s/he had scores below set thresholds (22 on the MacAndrew Alcoholism Scale and 28 on the Holmes Alcoholism Scale).^ For the final sample (N = 10), there was no reason to believe a relationship exists between antisocial personality syndrome in boys ages 8-15 and parental alcohol/drug dependency (Fisher's Exact Test {FET} P = 1.0). The small sample size primarily occurred as a result of 88.12% of the parents being classified in a questionable category in terms of alcohol/drug dependency.^ The sample was suggestive of a relationship between the fathers' Psychopathic Deviate (Pd) Scale scores as a measure of antisocial tendencies and the boy having antisocial personality syndrome (N = 75; P = .12). There was no evidence of such a relationship for mothers (N = 75; P = .97). ^
Resumo:
To ensure the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria determines if the dosimetric tools’ output passes the patient plan, it is important to see how these parameters influence the performance of the QA device. While analyzing the results of IMRT QA, it is important to understand the variability in the measurements. Due to the different form factors of the many QA methods, this reproducibility can be device dependent. These questions of patient-specific IMRT QA reproducibility and performance were investigated across five dosimeter systems: a helical diode array, radiographic film, ion chamber, diode array (AP field-by-field, AP composite, and rotational composite), and an in-house designed multiple ion chamber phantom. The reproducibility was gauged for each device by comparing the coefficients of variation (CV) across six patient plans. The performance of each device was determined by comparing each one’s ability to accurately label a plan as acceptable or unacceptable compared to a gold standard. All methods demonstrated a CV of less than 4%. Film proved to have the highest variability in QA measurement, likely due to the high level of user involvement in the readout and analysis. This is further shown by how the setup contributed more variation than the readout and analysis for all of the methods, except film. When evaluated for ability to correctly label acceptable and unacceptable plans, two distinct performance groups emerged with the helical diode array, AP composite diode array, film, and ion chamber in the better group; and the rotational composite and AP field-by-field diode array in the poorer group. Additionally, optimal threshold cutoffs were determined for each of the dosimetry systems. These findings, combined with practical considerations for factors such as labor and cost, can aid a clinic in its choice of an effective and safe patient-specific IMRT QA implementation.