5 resultados para performance measurement sourcing
em DigitalCommons@The Texas Medical Center
Resumo:
In the context of a healthcare organization, such as a hospital that provides medical care to its community, performance cannot be measured without special attention to quality. Indeed, quality is as important as finance not only in measuring performance for the organization, but also in securing the organization's viability and competitiveness in the long run.^ Yet quality today is not adequately understood and managed. An inductive framework for integrating finance and quality for purposes of organizational performance measurement as well as strategic planning is proposed in this dissertation. Future areas of research are discussed.^
Resumo:
Introduction: The Texas Occupational Safety & Health Surveillance System (TOSHSS) was created to collect, analyze and interpret occupational injury and illness data in order to decrease the impact of occupational injuries within the state of Texas. This process evaluation was performed midway through the 4-year grant to assess the efficiency and effectiveness of the surveillance system’s planning and implementation activities1. ^ Methods: Two evaluation guidelines published by the Centers for Disease Control and Prevention (CDC) were used as the theoretical models for this process evaluation. The Framework for Program Evaluation in Public Health was used to examine the planning and design of TOSHSS using logic models. The Framework for Evaluating Public Health Surveillance Systems was used to examine the implementation of approximately 60 surveillance activities, including uses of the data obtained from the surveillance system. ^ Results/Discussion: TOSHSS planning activities omitted the creation of a scientific advisory committee and specific activities designed to maintain contacts with stakeholders; and proposed activities should be reassessed and aligned with ongoing performance measurement criteria, including the role of collaborators in helping the surveillance system achieve each proposed activity. TOSHSS implementation activities are substantially meeting expectations and received an overall score of 61% for all activities being performed. TOSHSS is considered a surveillance system that is simple, flexible, acceptable, fairly stable, timely, moderately useful, with good data quality and a PVP of 86%. ^ Conclusions: Through the third year of TOSHSS implementation, the surveillance system is has made a considerable contribution to the collection of occupational injury and illness information within the state of Texas. Implementation of the nine recommendations provided under this process evaluation is expected to increase the overall usefulness of the surveillance system and assist TDSHS in reducing occupational fatalities, injuries, and diseases within the state of Texas. ^ 1 Disclaimer: The Texas Occupational Safety and Health Surveillance System is supported by Grant/Cooperative Agreement Number (U60 OH008473-01A1). The content of the current evaluation are solely the responsibility of the authors and do not necessarily represent the official views of the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.^
Resumo:
Strategic control is defined as the use of qualitative and quantitative tools for the evaluation of strategic organizational performance. Most research in strategic planning has focused on strategy formulation and implementation, but little work has been done on strategic performance evaluation particularly in the area of cancer research. The objective of this study was to identify strategic control approaches and financial performance metrics used by major cancer centers in the country as an initial step in expanding the theory and practice behind strategic organizational performance. Focusing on hospitals which share similar mandate and resource constraints was expected to improve measurement precision. The results indicate that most cancer centers use a wide selection of evaluation tools, but sophisticated analytical approaches were less common. In addition, there was evidence that high-performing centers tend to invest a larger degree of resources in the area of strategic performance analysis than centers showing lower financial results. The conclusions point to the need for incorporating higher degree of analytical power in order to improve the tracking of strategic performance. This study is one of the first to concentrate in the area of strategic control.^
Resumo:
Objective. In 2009, the International Expert Committee recommended the use of HbA1c test for diagnosis of diabetes. Although it has been recommended for the diagnosis of diabetes, its precise test performance among Mexican Americans is uncertain. A strong “gold standard” would rely on repeated blood glucose measurement on different days, which is the recommended method for diagnosing diabetes in clinical practice. Our objective was to assess test performance of HbA1c in detecting diabetes and pre-diabetes against repeated fasting blood glucose measurement for the Mexican American population living in United States-Mexico border. Moreover, we wanted to find out a specific and precise threshold value of HbA1c for Diabetes Mellitus (DM) and pre-diabetes for this high-risk population which might assist in better diagnosis and better management of patient diabetes. ^ Research design and methods. We used CCHC dataset for our study. In 2004, the Cameron County Hispanic Cohort (CCHC), now numbering 2,574, was established drawn from randomly selected households on the basis of 2000 Census tract data. The CCHC study randomly selected a subset of people (aged 18-64 years) in CCHC cohort households to determine the influence of SES on diabetes and obesity. Among the participants in Cohort-2000, 67.15% are female; all are Hispanic. ^ Individuals were defined as having diabetes mellitus (Fasting plasma glucose [FPG] ≥ 126 mg/dL or pre-diabetes (100 ≤ FPG < 126 mg/dL). HbA1c test performance was evaluated using receiver operator characteristic (ROC) curves. Moreover, change-point models were used to determine HbA1c thresholds compatible with FPG thresholds for diabetes and pre-diabetes. ^ Results. When assessing Fasting Plasma Glucose (FPG) is used to detect diabetes, the sensitivity and specificity of HbA1c≥ 6.5% was 75% and 87% respectively (area under the curve 0.895). Additionally, when assessing FPG to detect pre-diabetes, the sensitivity and specificity of HbA1c≥ 6.0% (ADA recommended threshold) was 18% and 90% respectively. The sensitivity and specificity of HbA1c≥ 5.7% (International Expert Committee recommended threshold) for detecting pre-diabetes was 31% and 78% respectively. ROC analyses suggest HbA1c as a sound predictor of diabetes mellitus (area under the curve 0.895) but a poorer predictor for pre-diabetes (area under the curve 0.632). ^ Conclusions. Our data support the current recommendations for use of HbA1c in the diagnosis of diabetes for the Mexican American population as it has shown reasonable sensitivity, specificity and accuracy against repeated FPG measures. However, use of HbA1c may be premature for detecting pre-diabetes in this specific population because of the poor sensitivity with FPG. It might be the case that HbA1c is differentiating the cases more effectively who are at risk of developing diabetes. Following these pre-diabetic individuals for a longer-term for the detection of incident diabetes may lead to more confirmatory result.^
Resumo:
CHARACTERIZATION OF THE COUNT RATE PERFORMANCE AND EVALUATION OF THE EFFECTS OF HIGH COUNT RATES ON MODERN GAMMA CAMERAS Michael Stephen Silosky, B.S. Supervisory Professor: S. Cheenu Kappadath, Ph.D. Evaluation of count rate performance (CRP) is an integral component of gamma camera quality assurance and measurement of system dead time (τ) is important for quantitative SPECT. The CRP of three modern gamma cameras was characterized using established methods (Decay and Dual Source) under a variety of experimental conditions. For the Decay method, input count rate was plotted against observed count rate and fit to the paralyzable detector model (PDM) to estimate τ (Rates method). A novel expression for observed counts as a function of measurement time interval was derived and the observed counts were fit to this expression to estimate τ (Counts method). Correlation and Bland-Altman analysis were performed to assess agreement in estimates of τ between methods. The dependencies of τ on energy window definition and incident energy spectrum were characterized. The Dual Source method was also used to estimate τ and its agreement with the Decay method under identical conditions and the effects of total activity and the ratio of source activities were investigated. Additionally, the effects of count rate on several performance metrics were evaluated. The CRP curves for each system agreed with the PDM at low count rates but deviated substantially at high count rates. Estimates of τ for the paralyzable portion of the CRP curves using the Rates and Counts methods were highly correlated (r=0.999) but with a small (~6%) difference. No significant difference was observed between the highly correlated estimates of τ using the Decay or Dual Source methods under identical experimental conditions (r=0.996). Estimates of τ increased as a power-law function with decreasing ratio of counts in the photopeak to the total counts and linearly with decreasing spectral effective energy. Dual Source method estimates of τ varied as a quadratic with the ratio of the single source to combined source activities and linearly with total activity used across a large range. Image uniformity, spatial resolution, and energy resolution degraded linearly with count rate and image distorting effects were observed. Guidelines for CRP testing and a possible method for the correction of count rate losses for clinical images have been proposed.