Resumo:
The Health Belief Model (HBM) provided the theoretical framework for examining Universal Precautions (UP) compliance factors by Emergency Department nurses. A random sample of Emergency Nurses Association (ENA) clinical nurses (n = 900) from five states (New York, New Jersey, California, Texas, and Florida), were surveyed to explore the factors related to their decision to comply with UP. Five-hundred-ninety-eight (598) useable questionnaires were analyzed. The responders were primarily female (84.9%), hospital based (94.6%), staff nurses (66.6%) who had a mean 8.5 years of emergency nursing experience. The nurses represented all levels of hospitals from rural (4.5%) to urban trauma centers (23.7%). The mean UP training hours was 3.0 (range 0-38 hours). Linear regression was used to analyze the four hypotheses. The first hypothesis evaluating perceived susceptibility and seriousness with reported UP use was not significant (p = $>$.05). Hypothesis 2 tested perceived benefits with internal and external barriers. Both perceived benefits and internal barriers as well as the overall regression were significant (F = 26.03, p = $<$0.001). Hypothesis 3 which tested modifying factors, cues to action, select demographic variables, and the main effects of the HBM with self reported UP compliance, was also significant (F = 12.39, p = $<$0.001). The additive effects were tested by use of a stepwise regression that assessed the contribution of each of the significant variables. The regression was significant (F = 12.39, p = $<$0.001) and explained 18% of the total variance. In descending order of contribution, the significant variables related to compliance were: internal barriers (t = $-$6.267; p = $<$0.001) such as the perception that because of the nature of the emergency care environment there is sometimes inadequate time to put on UP; cues to action (t = 3.195; p = 0.001) such as posted reminder signs or verbal reminders from peers; the number of Universal Precautions training hours (t = 3.667; p = $<$0.001) meaning that as the number of training hours increase so does compliance; perceived benefits (t = 3.466; p = 0.001) such as believing that UP will provide adequate barrier protection; and perceived susceptibility (t = 2.880; p = 0.004) such as feeling that they are at risk of exposure. ^
Resumo:
This study has the purpose of determining the barriers and facilitators to nurses' acceptance of the Johnson and Johnson Protectiv®* Plus IV catheter safety needle device and implications for needlestick injuries at St. Luke's Episcopal Hospital, Houston, Texas. A one-time cross-sectional survey of 620 responding nurses was conducted by this researcher during December, 2000. The study objectives were to: (1) describe the perceived (a) organizational and individual barriers and facilitators and (b) acceptance of implementation of the IV catheter device; (2) examine the relative importance of these predictors; (3) describe (a) perceived changes in needlestick injuries after implementation of the device; (b) the reported incidence of injuries; and (c) the extent of underreporting by nurses; and (4) examine the relative importance of (a) the preceding predictors and (b) acceptance of the device in predicting perceived changes in needlestick injuries. Safety climate and training were evaluated as organizational factors. Individual factors evaluated were experience with the device, including time using it and frequency of use, and background information, including nursing unit, and length of time as a nurse in this hospital and in total nursing career. The conceptual framework was based upon the safety climate model. Descriptive statistics and multiple and logistic regression were utilized to address the study objectives. ^ The findings showed widespread acceptance of the device and a strong perception that it reduced the number of needlesticks. Acceptance was notably predicted by adequate training, appropriate time between training and device use, solid safety climate, and short length of service, in that order. A barrier to acceptance was nurses' longtime of use of previous needle technologies. Over four-fifths of nurses were compliant in always using the device. Compliance had two facilitators: length of time using device and, to a lesser extent, safety climate. Rates of compliance tended to be lower among nurses in units in which the device was frequently used. ^ High quality training and an atmosphere of caring about nurse safety stand out as primary facilitators that other institutions would need to adopt in order to achieve maximum success in implementing safety programs involving utilization of new safety devices. ^