2 resultados para nitrogen urine level

em DigitalCommons@The Texas Medical Center


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. To determine the accuracy of the urine protein:creatinine ratio (pr:cr) in predicting 300 mg of protein in 24-hour urine collection in pregnant patients with suspected preeclampsia. ^ Methods. A systematic review was performed. Articles were identified through electronic databases and the relevant citations were hand searching of textbooks and review articles. Included studies evaluated patients for suspected preeclampsia with a 24-hour urine sample and a pr:cr. Only English language articles were included. The studies that had patients with chronic illness such as chronic hypertension, diabetes mellitus or renal impairment were excluded from the review. Two researchers extracted accuracy data for pr:cr relative to a gold standard of 300 mg of protein in 24-hour sample as well as population and study characteristics. The data was analyzed and summarized in tabular and graphical form. ^ Results. Sixteen studies were identified and only three studies met our inclusion criteria with 510 total patients. The studies evaluated different cut-points for positivity of pr:cr from 130 mg/g to 700 mg/g. Sensitivities and specificities for pr:cr of 130mg/g -150 mg/g were 90-93% and 33-65%, respectively; for a pr:cr of 300 mg/g were 81-95% and 52-80%, respectively; for a pr:cr of 600-700mg/g were 85-87% and 96-97%, respectively. ^ Conclusion. The value of a random pr:cr to exclude pre-eclampsia is limited because even low levels of pr:cr (130-150 mg/g) may miss up to 10% of patients with significant proteinuria. A pr:cr of more than 600 mg/g may obviate a 24-hour collection.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nitrogen dioxide (NO$\sb2)$ levels in sixteen substandard houses located in Houston, Texas were examined. The classification of the houses as substandard was based on an assessment of structural integrity which would affect air exchange rates. In these homes, unvented gas space heaters were operated as the primary source of heat.^ The Ogawa passive sampling device was used to measure NO$\sb2$ concentrations over 24 to 48-hour periods during generally cold weather. A sampler was placed in the kitchen and bedroom of each house. The female head of household was asked to wear a monitor during area monitoring to assess her personal exposure. Outdoor levels of NO$\sb2$ were also measured.^ Mean (standard deviation) levels of kitchen, bedroom and personal exposures were 280 (125) ppb, 256 (155) ppb and 164 (102) ppb, respectively. Additional short-term ($<$24 hours) samples were measured in three houses. The mean level of NO$\sb2$ measured outdoors was 51 ppb over the course of the study.^ The measurements obtained with the Ogawa sampler were compared to those levels obtained using a reference method (chemiluminescence). Outdoor levels measured with the diffusion samplers were 48% higher.^ These results suggest that wintertime NO$\sb2$ levels within substandard houses using gas appliances for heating and cooking are extremely elevated. Further work is needed to investigate the prevalence of possible health effects associated with these exposures. ^