2 resultados para multiple exposures

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Research has shown that elevations of only 10 mmHg diastolic blood pressure (BP) and 5 mmHg systolic BP are associated with substantial (as large as 50%) increases in risks for cardiovascular disease, a leading cause of death, worldwide. Epidemiological studies have found that particulate matter (PM) increases blood pressure (BP) and many biological mechanisms which may suggest that the organic matter of PM contributes to the increase in BP. To understand components of PM which may contribute to the increase in BP, this study focuses on diesel particulate matter (DPM) and polycyclic aromatic hydrocarbons (PAHs). To our knowledge, there have been only four epidemiological studies on BP and DPM, and no epidemiological studies on BP and PAHs. ^ Objective. Our objective was to evaluate the association between prevalent hypertension and two ambient exposures: DPM and PAHs amongst the Mano a Mano cohort. ^ Methods. The Mano a Mano cohort which was established by the M.D. Anderson Cancer Center in 2001, is comprised of individuals of Mexican origin residing in Houston, TX. Using geographical information systems, we linked modeled annual estimates of PAHs and DPM at the census track level from the U.S. Environmental Protection Agency's National-Scale Air Toxics Assessment to residential addresses of cohort members. Mixed-effects logistic regression models were applied to determine associations between DPM and PAHs and hypertension while adjusting for confounders. ^ Results. Ambient levels of DPM, categorized into quartiles, were not statistically associated with hypertension and did not indicate a dose response relationship. Ambient levels of PAHs, categorized into quartiles, were not associated with hypertension, but did indicate a dose response relationship in multiple models (for example: Q2: OR = 0.98; 95% CI, 0.73–1.31, Q3: OR = 1.08; 95% CI, 0.82–1.41, Q4: OR = 1.26; 95% CI, 0.94–1.70). ^ Conclusion. This is the first assessment to analyze the relationship between ambient levels of PAHs and hypertension and it is amongst a few studies investigating the association between ambient levels of DPM and hypertension. Future analyses are warranted to explore the effects DPM and PAHs using different categorizations in order to clarify their relationships with hypertension.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^