2 resultados para material outgassing rate

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A detailed microdosimetric characterization of the M. D. Anderson 42 MeV (p,Be) fast neutron beam was performed using the techniques of microdosimetry and a 1/2 inch diameter Rossi proportional counter. These measurements were performed at 5, 15, and 30 cm depths on the central axis, 3 cm inside, and 3 cm outside the field edge for 10 $\times$ 10 and 20 $\times$ 20 cm field sizes. Spectra were also measured at 5 and 15 cm depth on central axis for a 6 $\times$ 6 cm field size. Continuous slowing down approximation calculations were performed to model the nuclear processes that occur in the fast neutron beam. Irradiation of the CR-39 was performed using a tandem electrostatic accelerator for protons of 10, 6, and 3 MeV and alpha particles of 15, 10, and 7 MeV incident energy on target at angles of incidence from 0 to 85 degrees. The critical angle as well as track etch rate and normal incidence diameter versus linear energy transfer (LET) were obtained from these measurements. The bulk etch rate was also calculated from these measurements. Dose response of the material was studied, and the angular distribution of charged particles created by the fast neutron beam was measured with CR-39. The efficiency of CR-39 was calculated versus that of the Rossi chamber, and an algorithm was devised for derivation of LET spectra from the major and minor axis dimensions of the observed tracks. The CR-39 was irradiated in the same positions as the Rossi chamber, and the derived spectra were compared directly. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Material Safety Data Sheets (MSDSs) are an integral component of occupational hazard communication systems. These documents are used to disseminate hazard information to workers on chemical substances. The primary purpose of this study was to investigate the comprehensibility of MSDSs by workers at an international level. ^ A total of 117 employees of a multi-national petrochemical company participated; thirty-nine (39) each in the United States, Canada and the United Kingdom. Overall participation rate of those approached to participate was 82%. These countries were selected as they each utilize one of the three major existing hazard communication systems for fixed workplaces. The systems are comprised of the Occupational Safety and Health Administration's Hazard Communication Standard in the United States, the Workplace Hazardous Materials Information System (WHMIS) in Canada, and the compilation of several European Union directives addressing classification, labeling of substances and preparations, and MSDSs in Europe. ^ A pretest posttest randomized study design was used, with the posttest being comparable to an open book test. The results of this research indicated that only about two-thirds of the information on the MSDSs was comprehended by the workers with a significant difference identified among study participants based on country comparisons. This data was fairly consistent with the results of previous MSDS comprehensibility studies conducted in the United States. There was no significant difference in the comprehension level among study participants when taking into account the international hazard communication standard that the MSDS complied with. Marginally, age, education level and experience level did not have a significant impact on the comprehension level. ^ Participants did find MSDSs to be satisfactory in providing the information needed to protect them regardless of their views on the readability and formatting of MSDSs. The health-related information was the least comprehended as less than half of it was comprehended on the basis of the responses. The findings from this research suggest that there is much work needed yet to make MSDSs more comprehensible on a global basis, particularly regarding health-related information. ^