6 resultados para manual performance evaluation

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bayesian adaptive randomization (BAR) is an attractive approach to allocate more patients to the putatively superior arm based on the interim data while maintains good statistical properties attributed to randomization. Under this approach, patients are adaptively assigned to a treatment group based on the probability that the treatment is better. The basic randomization scheme can be modified by introducing a tuning parameter, replacing the posterior estimated response probability, setting a boundary to randomization probabilities. Under randomization settings comprised of the above modifications, operating characteristics, including type I error, power, sample size, imbalance of sample size, interim success rate, and overall success rate, were evaluated through simulation. All randomization settings have low and comparable type I errors. Increasing tuning parameter decreases power, but increases imbalance of sample size and interim success rate. Compared with settings using the posterior probability, settings using the estimated response rates have higher power and overall success rate, but less imbalance of sample size and lower interim success rate. Bounded settings have higher power but less imbalance of sample size than unbounded settings. All settings have better performance in the Bayesian design than in the frequentist design. This simulation study provided practical guidance on the choice of how to implement the adaptive design. ^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. The study reviewed one year of Texas hospital discharge data and Trauma Registry data for the 22 trauma services regions in Texas to identify regional variations in capacity, process of care and clinical outcomes for trauma patients, and analyze the statistical associations among capacity, process of care, and outcomes. ^ Methods. Cross sectional study design covering one year of state-wide Texas data. Indicators of trauma capacity, trauma care processes, and clinical outcomes were defined and data were collected on each indicator. Descriptive analyses were conducted of regional variations in trauma capacity, process of care, and clinical outcomes at all trauma centers, at Level I and II trauma centers and at Level III and IV trauma centers. Multilevel regression models were performed to test the relations among trauma capacity, process of care, and outcome measures at all trauma centers, at Level I and II trauma centers and at Level III and IV trauma centers while controlling for confounders such as age, gender, race/ethnicity, injury severity, level of trauma centers and urbanization. ^ Results. Significant regional variation was found among the 22 trauma services regions across Texas in trauma capacity, process of care, and clinical outcomes. The regional trauma bed rate, the average staffed bed per 100,000 varied significantly by trauma service region. Pre-hospital trauma care processes were significantly variable by region---EMS time, transfer time, and triage. Clinical outcomes including mortality, hospital and intensive care unit length of stay, and hospital charges also varied significantly by region. In multilevel regression analysis, the average trauma bed rate was significantly related to trauma care processes including ambulance delivery time, transfer time, and triage after controlling for age, gender, race/ethnicity, injury severity, level of trauma centers, and urbanization at all trauma centers. Transfer time only among processes of care was significant with the average trauma bed rate by region at Level III and IV. Also trauma mortality only among outcomes measures was significantly associated with the average trauma bed rate by region at all trauma centers. Hospital charges only among outcomes measures were statistically related to trauma bed rate at Level I and II trauma centers. The effect of confounders on processes and outcomes such as age, gender, race/ethnicity, injury severity, and urbanization was found significantly variable by level of trauma centers. ^ Conclusions. Regional variation in trauma capacity, process, and outcomes in Texas was extensive. Trauma capacity, age, gender, race/ethnicity, injury severity, level of trauma centers and urbanization were significantly associated with trauma process and clinical outcomes depending on level of trauma centers. ^ Key words: regionalized trauma systems, trauma capacity, pre-hospital trauma care, process, trauma outcomes, trauma performance, evaluation measures, regional variations ^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Strategic control is defined as the use of qualitative and quantitative tools for the evaluation of strategic organizational performance. Most research in strategic planning has focused on strategy formulation and implementation, but little work has been done on strategic performance evaluation particularly in the area of cancer research. The objective of this study was to identify strategic control approaches and financial performance metrics used by major cancer centers in the country as an initial step in expanding the theory and practice behind strategic organizational performance. Focusing on hospitals which share similar mandate and resource constraints was expected to improve measurement precision. The results indicate that most cancer centers use a wide selection of evaluation tools, but sophisticated analytical approaches were less common. In addition, there was evidence that high-performing centers tend to invest a larger degree of resources in the area of strategic performance analysis than centers showing lower financial results. The conclusions point to the need for incorporating higher degree of analytical power in order to improve the tracking of strategic performance. This study is one of the first to concentrate in the area of strategic control.^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this research and development project was to develop a method, a design, and a prototype for gathering, managing, and presenting data about occupational injuries.^ State-of-the-art systems analysis and design methodologies were applied to the long standing problem in the field of occupational safety and health of processing workplace injuries data into information for safety and health program management as well as preliminary research about accident etiologies. The top-down planning and bottom-up implementation approach was utilized to design an occupational injury management information system. A description of a managerial control system and a comprehensive system to integrate safety and health program management was provided.^ The project showed that current management information systems (MIS) theory and methods could be applied successfully to the problems of employee injury surveillance and control program performance evaluation. The model developed in the first section was applied at The University of Texas Health Science Center at Houston (UTHSCH).^ The system in current use at the UTHSCH was described and evaluated, and a prototype was developed for the UTHSCH. The prototype incorporated procedures for collecting, storing, and retrieving records of injuries and the procedures necessary to prepare reports, analyses, and graphics for management in the Health Science Center. Examples of reports, analyses, and graphics presenting UTHSCH and computer generated data were included.^ It was concluded that a pilot test of this MIS should be implemented and evaluated at the UTHSCH and other settings. Further research and development efforts for the total safety and health management information systems, control systems, component systems, and variable selection should be pursued. Finally, integration of the safety and health program MIS into the comprehensive or executive MIS was recommended. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the administration-time-dependent effects of a stimulant (Dexedrine 5-mg), a sleep-inducer (Halcion 0.25-mg) and placebo (control) on human performance. The investigation was conducted on 12 diurnally active (0700-2300) male adults (23-38 yrs) using a double-blind, randomized sixway-crossover three-treatment, two-timepoint (0830 vs 2030) design. Performance tests were conducted hourly during sleepless 13-hour studies using a computer generated, controlled and scored multi-task cognitive performance assessment battery (PAB) developed at the Walter Reed Army Institute of Research. Specific tests were Simple and Choice Reaction Time, Serial Addition/Subtraction, Spatial Orientation, Logical Reasoning, Time Estimation, Response Timing and the Stanford Sleepiness Scale. The major index of performance was "Throughput", a combined measure of speed and accuracy.^ For the Placebo condition, Single and Group Cosinor Analysis documented circadian rhythms in cognitive performance for the majority of tests, both for individuals and for the group. Performance was best around 1830-2030 and most variable around 0530-0700 when sleepiness was greatest (0300).^ Morning Dexedrine dosing marginally enhanced performance an average of 3% with reference to the corresponding in time control level. Dexedrine AM also increased alertness by 10% over the AM control. Dexedrine PM failed to improve performance with reference to the corresponding PM control baseline. With regard to AM and PM Dexedrine administrations, AM performance was 6% better with subjects 25% more alert.^ Morning Halcion administration caused a 7% performance decrement and 16% increase in sleepiness and a 13% decrement and 10% increase in sleepiness when administered in the evening compared to corresponding in time control data. Performance was 9% worse and sleepiness 24% greater after evening versus morning Halcion administration.^ These results suggest that for evening Halcion dosing, the overnight sleep deprivation occurring in coincidence with the nadir in performance due to circadian rhythmicity together with the CNS depressant effects combine to produce performance degradation. For Dexedrine, morning administration resulted in only marginal performance enhancement; Dexedrine in the evening was less effective, suggesting the 5-mg dose level may be too low to counteract the partial sleep deprivation and nocturnal nadir in performance. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

CHARACTERIZATION OF THE COUNT RATE PERFORMANCE AND EVALUATION OF THE EFFECTS OF HIGH COUNT RATES ON MODERN GAMMA CAMERAS Michael Stephen Silosky, B.S. Supervisory Professor: S. Cheenu Kappadath, Ph.D. Evaluation of count rate performance (CRP) is an integral component of gamma camera quality assurance and measurement of system dead time (τ) is important for quantitative SPECT. The CRP of three modern gamma cameras was characterized using established methods (Decay and Dual Source) under a variety of experimental conditions. For the Decay method, input count rate was plotted against observed count rate and fit to the paralyzable detector model (PDM) to estimate τ (Rates method). A novel expression for observed counts as a function of measurement time interval was derived and the observed counts were fit to this expression to estimate τ (Counts method). Correlation and Bland-Altman analysis were performed to assess agreement in estimates of τ between methods. The dependencies of τ on energy window definition and incident energy spectrum were characterized. The Dual Source method was also used to estimate τ and its agreement with the Decay method under identical conditions and the effects of total activity and the ratio of source activities were investigated. Additionally, the effects of count rate on several performance metrics were evaluated. The CRP curves for each system agreed with the PDM at low count rates but deviated substantially at high count rates. Estimates of τ for the paralyzable portion of the CRP curves using the Rates and Counts methods were highly correlated (r=0.999) but with a small (~6%) difference. No significant difference was observed between the highly correlated estimates of τ using the Decay or Dual Source methods under identical experimental conditions (r=0.996). Estimates of τ increased as a power-law function with decreasing ratio of counts in the photopeak to the total counts and linearly with decreasing spectral effective energy. Dual Source method estimates of τ varied as a quadratic with the ratio of the single source to combined source activities and linearly with total activity used across a large range. Image uniformity, spatial resolution, and energy resolution degraded linearly with count rate and image distorting effects were observed. Guidelines for CRP testing and a possible method for the correction of count rate losses for clinical images have been proposed.