2 resultados para housing environment

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Manufactured housing has been found to have substantial levels of formaldehyde in the indoor air. Because mobile homes are more affordable than conventional housing, there has been a large increase in their use in the U.S. This increase in mobile home use has been substantial in the sunbelt regions such as Texas, where high temperatures and humidities may enhance out-gassing of formaldehyde and other volatile organic compounds from construction and furnishing materials and increase any potential health hazards.^ The influences of environmental, architectural and temporal factors on the presence of indoor formaldehyde and other organic compounds were investigated in conjunction with the Texas Indoor Air Quality Study of manufactured housing. A matched pair of mobile homes, one with electric heating and cooking utilities and the other with propane gas utilities, were used for a series of controlled experiments over a fourteen month period from October, 1982 through November, 1983.^ Over this fourteen month period formaldehyde levels decreased approximately 33%. Daily fluctuations of 20% to 40% were observed even with a constant indoor temperature. An increase in indoor temperature of 8(DEGREES)C doubled the measured formaldehyde concentration. Opening windows resulted in decreases of indoor formaldehyde levels of up to 50%. Studies of the impact of propane as a cooking source showed no increase in formaldehyde levels with stove use.^ The presence and concentration of selected volatile organic compounds is influenced greatest by occupancy. Occupants continually open and close windows and doors, vary the operation and settings (temperature) of air control systems, and vary in their selection of furnishings and use of consumer products, which may act as sources of indoor air contaminants. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^