3 resultados para elevator

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study to assess possible exposure to carcinogenic metabolites (aflatoxins) from a mold Aspergillus flavus has been made in a rice producing area of Brazoria County, Texas. One hundred samples of unmilled rice were analyzed by thin-layer chromatography (TLC) for the amount of aflatoxin produced by the mold during rice growth and storage. Two well water samples and two rice elevator dust samples were also checked for possible aflatoxin content. The mortality rates from gastrointestinal and urinary tract cancers in the rice-growing part of the county were compared with mortality rates in the nonrice-producing areas of the same county.^ This study was an outgrowth of an earlier investigation by Cech and co-workers in Brazoria County which focused on environmental differences, specifically on the quality of drinking water in the former residences of decedents from primary liver cancer. It also compared subjects who died from other causes. The author of this dissertation participated in this phase of the overall investigation by performing some of the chemical analyses and by preparing synographic maps of water quality, and thus, part of those results from the early phase is also included in this manuscript.^ No aflatoxin was detected by TLC methods. However, when extracts of rice dust were checked for mutagenesis by the Ames Salmonella-microsome assay as a supplement to the TLC analysis, the result suggested that these dusts might have contained mutagenic material. The age-adjusted mortality rates in the rice-growing area were higher than those in the comparison area for both male and female gastrointestinal tract cancer and for male urinary tract cancer, but the differences were not statistically significant. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Point-of-decision signs to promote stair use have been found to be effective in various environments. However, these signs have been more consistently successful in public access settings that use escalators, such as shopping centers and transportation stations, compared to worksite settings, which are more likely to contain elevators that are not directly adjacent to the stairs. Therefore, this study tested the effectiveness of two point-of-decision sign prompts to increase stair use in a university worksite setting. Also, this study investigated the importance of the message content of the signs. One sign displayed a general health promotion message, while the other sign presented more specific information. Overall, this project examined whether the presence of the point-of-decision signs increases stair use. In addition, this research determined whether the general or specific sign promotes greater stair use. ^ Inconspicuous observers measured stair use both before the signs were present and while they were posted. The study setting was the University of Texas School of Nursing, and the target population was anyone who entered the building, including employees, students, and visitors. The study was conducted over six weeks and included two weeks of baseline measurement, two weeks with the general sign posted, and two weeks with the specific sign posted. Each sign was displayed on a stand in the decision point area near the stairs and the elevator. Logistic regression was used to analyze the data. ^ After adjustment for covariates, the odds of stair use were significantly greater during the intervention period than the baseline period. Furthermore, the specific sign period showed significantly greater odds of stair use than the general sign period. These results indicate that a point-of-decision sign intervention can be effective at promoting stair use in a university worksite setting and that a sign with a specific health information message may be more effective at promoting stair use than a sign with a general health promotion message. These findings can be considered when planning future worksite and university based stair promotion interventions.^