4 resultados para dose optimization

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate normal tissue dose reduction in step-and-shoot intensity-modulated radiation therapy (IMRT) on the Varian 2100 platform by tracking the multileaf collimator (MLC) apertures with the accelerator jaws. Methods: Clinical radiation treatment plans for 10 thoracic, 3 pediatric and 3 head and neck patients were converted to plans with the jaws tracking each segment’s MLC apertures. Each segment was then renormalized to account for the change in collimator scatter to obtain target coverage within 1% of that in the original plan. The new plans were compared to the original plans in a commercial radiation treatment planning system (TPS). Reduction in normal tissue dose was evaluated in the new plan by using the parameters V5, V10, and V20 in the cumulative dose-volume histogram for the following structures: total lung minus GTV (gross target volume), heart, esophagus, spinal cord, liver, parotids, and brainstem. In order to validate the accuracy of our beam model, MLC transmission measurements were made and compared to those predicted by the TPS. Results: The greatest change between the original plan and new plan occurred at lower dose levels. The reduction in V20 was never more than 6.3% and was typically less than 1% for all patients. The reduction in V5 was 16.7% maximum and was typically less than 3% for all patients. The variation in normal tissue dose reduction was not predictable, and we found no clear parameters that indicated which patients would benefit most from jaw tracking. Our TPS model of MLC transmission agreed with measurements with absolute transmission differences of less than 0.1 % and thus uncertainties in the model did not contribute significantly to the uncertainty in the dose determination. Conclusion: The amount of dose reduction achieved by collimating the jaws around each MLC aperture in step-and-shoot IMRT does not appear to be clinically significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current shortcomings in cancer therapy require the generation of new, broadly applicable, potent, targeted treatments. Here, an adenovirus is engineered to replicate specifically in cells with active human telomerase promotion using a modified hTERT promoter, fused to a CMV promoter element. The virus was also modified to contain a visible reporter transgene, GFP. The virus, Ad/hTC-GFP-E1 was characterized in vitro and demonstrated tumor specific activity both by dose and over time course experiments in a variety of cell lines. In vivo, Ad/hTC-GFP-E1 was affected at suppressing tumor growth and providing a survival benefit without causing any measurable toxicity. To increase the host range of the vector, the fiber region was modified to contain an RGD-motif. The vector, AdRGD/hTC-GFP-E1, was recharacterized in vitro, revealing heightened levels of infectivity and toxicity however maintaining a therapeutic window between cancer and normal cell toxicity. AdRGD/hTC-GFP-E1 was administered in vivo by limb perfusion and was observed to be tumor specific both in expression and replication. To further enhance the efficacy of viral vectors in lung delivery, asthma medications were investigated for their abilities to enhance transgene delivery and expression. A combination of bronchodilators, mast cell inhibitors, and mucolytic agents was devised which demonstrated fold increases in expression in immunocompetent mouse lungs as single agents and more homogenous, intense levels of expression when done in combination of all agents. To characterize the methods in which some cancers are resistant or may become resistant to oncolytic treatments, several small molecule inhibitors of metabolic pathways were applied in combination with oncolytic infection in vitro. SP600125 and PD 98059, respective JNK and ERK inhibitors, successfully suppressed oncolytic toxicity, however did not affect infectivity or transgene expression of Ad/hTC-GFP-E1. JNK and ERK inhibition did significantly suppress viral replication, however, as analyzed by lysate transfer and titration assays. In contrast, SB 203580, an inhibitor for p38, did not demonstrate any protective effects with infected cells. Flow cytometric analysis indicated a possible correlation with G1 arrest and suppressed viral production, however more compounds must be investigated to clarify this observation. ^