4 resultados para donor acceptor pair
em DigitalCommons@The Texas Medical Center
Resumo:
Every x-ray attenuation curve inherently contains all the information necessary to extract the complete energy spectrum of a beam. To date, attempts to obtain accurate spectral information from attenuation data have been inadequate.^ This investigation presents a mathematical pair model, grounded in physical reality by the Laplace Transformation, to describe the attenuation of a photon beam and the corresponding bremsstrahlung spectral distribution. In addition the Laplace model has been mathematically extended to include characteristic radiation in a physically meaningful way. A method to determine the fraction of characteristic radiation in any diagnostic x-ray beam was introduced for use with the extended model.^ This work has examined the reconstructive capability of the Laplace pair model for a photon beam range of from 50 kVp to 25 MV, using both theoretical and experimental methods.^ In the diagnostic region, excellent agreement between a wide variety of experimental spectra and those reconstructed with the Laplace model was obtained when the atomic composition of the attenuators was accurately known. The model successfully reproduced a 2 MV spectrum but demonstrated difficulty in accurately reconstructing orthovoltage and 6 MV spectra. The 25 MV spectrum was successfully reconstructed although poor agreement with the spectrum obtained by Levy was found.^ The analysis of errors, performed with diagnostic energy data, demonstrated the relative insensitivity of the model to typical experimental errors and confirmed that the model can be successfully used to theoretically derive accurate spectral information from experimental attenuation data. ^
Resumo:
Background. Racial disparities in healthcare span such areas as access, outcomes after procedures, and patient satisfaction. Previous work suggested that minorities experience less healthcare and worse survival rates. In adult orthotopic liver transplantation (OLT) mixed results have been reported, with some showing African-American recipients having poor survival compared to Caucasians, and others finding no such discrepancy. ^ Purpose. This study’s purpose was to analyze the most recent United Network for Organ Sharing (UNOS) data, both before and after the implementation of the Model for End-Stage Liver Disease (MELD)/Pediatric End-Stage Liver Disease (PELD) scoring system, to determine if minority racial groups still experience poor outcomes after OLT. ^ Methods. The UNOS dataset for 1992-2001 (Era I) and 2002-2007 (Era II) was used. Patient survival rates for each Era and for adult and pediatric recipients were analyzed with adjustment. A separate multivariate analysis was performed on African-American adult patients in Era II in order to identify unique predictors for poor patient survival. ^ Results. The overall study included 66,118 OLT recipients. The majority were Caucasian (78%), followed by Hispanics (13%) and African-Americans (9%). Hispanic and African-American adults were more likely to be female, have Hepatitis C, to be in the intensive care unit (ICU) or ventilated at time of OLT, to have a MELD score ≥23, to have a lower education level, and to have public insurance when compared to Caucasian adults (all p-values < 0.05). Hispanic and African-American pediatric recipients were more likely have public insurance and less likely to receive a living donor OLT than were Caucasian pediatric OLT recipients (p <0.05). There was no difference in the likelihood of having a PELD score ≥21 among racial groups (p >0.40). African-American adults in Era I and Era II had worse patient survival rates than both Caucasians and Hispanic (pair-wise p-values <0.05). This same disparity was seen for pediatric recipients in Era I, but not in Era II. Multivariate analysis of African-American recipients revealed no unique predictors of patient death. ^ Conclusions. African-American race is still a predictor of poor outcome after adult OLT, even after adjustment for multiple clinical, demographic, and liver disease severity variables. Although African-American and Hispanic subgroups share many characteristics previously thought to increase risk of post-OLT death, only African-American patients have poor survival rates when compared to Caucasians. ^
Resumo:
Accurate screening for anemia at Red Cross blood donor clinics is essential to maintain a safe national blood supply. Despite the importance of identifying anemia correctly by measurement of hemoglobin or hematocrit (hemoglobin/hematocrit) there is no consensus regarding the efficacy of the current two stage screening method which uses the Readacrit$\sp{\rm tm}$ microhematocrit in conjunction with copper sulfate.^ A cross-sectional study was implemented in which hemoglobin/hematocrit was measured, with the present method and four new devices, on 504 prospective blood donors at a Canadian Red Cross permanent blood donor clinic in London, Canada. Concurrently gathered, venous and capillary blood samples were tested by each device and compared to Coulter S IV$\sp{\rm tm}$ determined venous standard readings. Instrument hemoglobin/hematocrit means were statistically calibrated to the standard ones in order to appraise systematic deviations from the standard. Classification analysis was employed to assess concordance between each instrument and the standard when classifying prospective donors as anemic or non-anemic. This was done both when each instrument was used alone (single stage) and when copper sulfate was used as a preliminary screen (two stage) and simulated over a range of anemia prevalences. The Hemoximeter$\sp{\rm tm}$ and Compur M1000$\sp{\rm tm}$ devices had the highest correlations of hemoglobin measurements with the standard ones for both capillary (n.s.) and venous blood (p $<$.05). Analysis of variance (anova) also showed them to be the most accurate (p $<$.05), as did both single and two stage classification analysis, therefore, they are both recommended. There was a smaller difference between instruments for two stage than for single stage screening; therefore instrument choice is less crucial for the former. The present method was adequate for two stage screening as tested but simulations showed that it would discriminate poorly in populations with a higher prevalence of anemia. The Stat-crit and Readacrit, which measure hematocrit, became less accurate at crucial low hematocrit levels. In light of this finding and the introduction of new, effective and easy to use hemoglobin measuring instruments, the continued use of hematocrit as a surrogate for hemoglobin, is not recommended. ^
Resumo:
Background. End-stage liver disease (ESLD) is an irreversible condition that leads to the imminent complete failure of the liver. Orthotopic liver transplantation (OLT) has been well accepted as the best curative option for patients with ESLD. Despite the progress in liver transplantation, the major limitation nowadays is the discrepancy between donor supply and organ demand. In an effort to alleviate this situation, mismatched donor and recipient gender or race livers are being used. However, the simultaneous impact of donor and recipient gender and race mismatching on patient survival after OLT remains unclear and relatively challenging to surgeons. ^ Objective. To examine the impact of donor and recipient gender and race mismatching on patient survival after OLT using the United Network for Organ Sharing (UNOS) database. ^ Methods. A total of 40,644 recipients who underwent OLT between 2002 and 2011 were included. Kaplan-Meier survival curves and the log-rank tests were used to compare the survival rates among different donor-recipient gender and race combinations. Univariate Cox regression analysis was used to assess the association of donor-recipient gender and race mismatching with patient survival after OLT. Multivariable Cox regression analysis was used to model the simultaneous impact of donor-recipient gender and race mismatching on patient survival after OLT adjusting for a list of other risk factors. Multivariable Cox regression analysis stratifying on recipient hepatitis C virus (HCV) status was also conducted to identify the variables that were differentially associated with patient survival in HCV + and HCV − recipients. ^ Results. In the univariate analysis, compared to male donors to male recipients, female donors to male recipients had a higher risk of patient mortality (HR, 1.122; 95% CI, 1.065–1.183), while in the multivariable analysis, male donors to female recipients experienced an increased mortality rates (adjusted HR, 1.114; 95% CI, 1.048–1.184). Compared to white donors to white recipients, Hispanic donors to black recipients had a higher risk of patient mortality (HR, 1.527; 95% CI, 1.293–1.804) in the univariate analysis, and similar result (adjusted HR, 1.553; 95% CI, 1.314–1.836) was noted in multivariable analysis. After the stratification on recipient HCV status in the multivariable analysis, HCV + mismatched recipients appeared to be at greater risk of mortality than HCV − mismatched recipients. Female donors to female HCV − recipients (adjusted HR, 0.843; 95% CI, 0.769–0.923), and Hispanic HCV + recipients receiving livers from black donors (adjusted HR, 0.758; 95% CI, 0.598–0.960) had a protective effect on patient survival after OLT. ^ Conclusion. Donor-recipient gender and race mismatching adversely affect patient survival after OLT, both independently and after the adjustment for other risk factors. Female recipient HCV status is an important effect modifier in the association between donor-recipient gender combination and patient survival.^