2 resultados para donor
em DigitalCommons@The Texas Medical Center
Resumo:
Accurate screening for anemia at Red Cross blood donor clinics is essential to maintain a safe national blood supply. Despite the importance of identifying anemia correctly by measurement of hemoglobin or hematocrit (hemoglobin/hematocrit) there is no consensus regarding the efficacy of the current two stage screening method which uses the Readacrit$\sp{\rm tm}$ microhematocrit in conjunction with copper sulfate.^ A cross-sectional study was implemented in which hemoglobin/hematocrit was measured, with the present method and four new devices, on 504 prospective blood donors at a Canadian Red Cross permanent blood donor clinic in London, Canada. Concurrently gathered, venous and capillary blood samples were tested by each device and compared to Coulter S IV$\sp{\rm tm}$ determined venous standard readings. Instrument hemoglobin/hematocrit means were statistically calibrated to the standard ones in order to appraise systematic deviations from the standard. Classification analysis was employed to assess concordance between each instrument and the standard when classifying prospective donors as anemic or non-anemic. This was done both when each instrument was used alone (single stage) and when copper sulfate was used as a preliminary screen (two stage) and simulated over a range of anemia prevalences. The Hemoximeter$\sp{\rm tm}$ and Compur M1000$\sp{\rm tm}$ devices had the highest correlations of hemoglobin measurements with the standard ones for both capillary (n.s.) and venous blood (p $<$.05). Analysis of variance (anova) also showed them to be the most accurate (p $<$.05), as did both single and two stage classification analysis, therefore, they are both recommended. There was a smaller difference between instruments for two stage than for single stage screening; therefore instrument choice is less crucial for the former. The present method was adequate for two stage screening as tested but simulations showed that it would discriminate poorly in populations with a higher prevalence of anemia. The Stat-crit and Readacrit, which measure hematocrit, became less accurate at crucial low hematocrit levels. In light of this finding and the introduction of new, effective and easy to use hemoglobin measuring instruments, the continued use of hematocrit as a surrogate for hemoglobin, is not recommended. ^
Resumo:
Background. End-stage liver disease (ESLD) is an irreversible condition that leads to the imminent complete failure of the liver. Orthotopic liver transplantation (OLT) has been well accepted as the best curative option for patients with ESLD. Despite the progress in liver transplantation, the major limitation nowadays is the discrepancy between donor supply and organ demand. In an effort to alleviate this situation, mismatched donor and recipient gender or race livers are being used. However, the simultaneous impact of donor and recipient gender and race mismatching on patient survival after OLT remains unclear and relatively challenging to surgeons. ^ Objective. To examine the impact of donor and recipient gender and race mismatching on patient survival after OLT using the United Network for Organ Sharing (UNOS) database. ^ Methods. A total of 40,644 recipients who underwent OLT between 2002 and 2011 were included. Kaplan-Meier survival curves and the log-rank tests were used to compare the survival rates among different donor-recipient gender and race combinations. Univariate Cox regression analysis was used to assess the association of donor-recipient gender and race mismatching with patient survival after OLT. Multivariable Cox regression analysis was used to model the simultaneous impact of donor-recipient gender and race mismatching on patient survival after OLT adjusting for a list of other risk factors. Multivariable Cox regression analysis stratifying on recipient hepatitis C virus (HCV) status was also conducted to identify the variables that were differentially associated with patient survival in HCV + and HCV − recipients. ^ Results. In the univariate analysis, compared to male donors to male recipients, female donors to male recipients had a higher risk of patient mortality (HR, 1.122; 95% CI, 1.065–1.183), while in the multivariable analysis, male donors to female recipients experienced an increased mortality rates (adjusted HR, 1.114; 95% CI, 1.048–1.184). Compared to white donors to white recipients, Hispanic donors to black recipients had a higher risk of patient mortality (HR, 1.527; 95% CI, 1.293–1.804) in the univariate analysis, and similar result (adjusted HR, 1.553; 95% CI, 1.314–1.836) was noted in multivariable analysis. After the stratification on recipient HCV status in the multivariable analysis, HCV + mismatched recipients appeared to be at greater risk of mortality than HCV − mismatched recipients. Female donors to female HCV − recipients (adjusted HR, 0.843; 95% CI, 0.769–0.923), and Hispanic HCV + recipients receiving livers from black donors (adjusted HR, 0.758; 95% CI, 0.598–0.960) had a protective effect on patient survival after OLT. ^ Conclusion. Donor-recipient gender and race mismatching adversely affect patient survival after OLT, both independently and after the adjustment for other risk factors. Female recipient HCV status is an important effect modifier in the association between donor-recipient gender combination and patient survival.^