2 resultados para common average reference

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

INFLUENCE OF ANCHORING ON MISCARRIAGE RISK PERCEPTION ASSOCIATED WITH AMNIOCENTESIS Publication No. ___________ Regina Nuccio, BS Supervisory Professor: Claire N. Singletary, MS, CGC Amniocentesis is the most common invasive procedure performed during pregnancy (Eddleman, et al., 2006). One important factor that women consider when making a decision about amniocentesis is the risk of miscarriage associated with the procedure. People use heuristics such as anchoring, the action of using a prior belief regarding the magnitude of risk as a frame of reference for new information to be synthesized, to better understand risks that they encounter in their lives. This study aimed to determine a woman’s perception of miscarriage risk associated with amniocentesis before and after a genetic counseling session and to determine what factors are most likely to anchor a woman’s perception of miscarriage risk associated with amniocentesis. Most women perceived the risk as low or average pre-counseling and were likely to indicate the numeric risk of amniocentesis as <1% risk. A higher percentage of patients correctly identified the numeric risk as <1% post-counseling when compared to pre-counseling. However, the majority of patients’ feeling about the risk perception did not change after the genetic counseling session (60%), regardless of how they perceived the risk before discussing amniocentesis with a genetic counselor. Those whose risk perception did change after discussing amniocentesis with a genetic counselor showed a decreased risk perception (p<0.0001). Of the multitude of factors studied, only two showed significance: having a friend or relative with a personal or family history of a genetic disorder was associated with a lower risk perception (p=0.001) and having a child already was associated with a lower risk perception (p=0.038). The lack of significant factors may reflect the uniqueness of each patient’s heuristic framework and reinforces the importance of genetic counseling to elucidate individual concerns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurement of the absorbed dose from ionizing radiation in medical applications is an essential component to providing safe and reproducible patient care. There are a wide variety of tools available for measuring radiation dose; this work focuses on the characterization of two common, solid-state dosimeters in medical applications: thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD). There were two main objectives to this work. The first objective was to evaluate the energy dependence of TLD and OSLD for non-reference measurement conditions in a radiotherapy environment. The second objective was to fully characterize the OSLD nanoDot in a CT environment, and to provide validated calibration procedures for CT dose measurement using OSLD. Current protocols for dose measurement using TLD and OSLD generally assume a constant photon energy spectrum within a nominal beam energy regardless of measurement location, tissue composition, or changes in beam parameters. Variations in the energy spectrum of therapeutic photon beams may impact the response of TLD and OSLD and could thereby result in an incorrect measure of dose unless these differences are accounted for. In this work, we used a Monte Carlo based model to simulate variations in the photon energy spectra of a Varian 6MV beam; then evaluated the impact of the perturbations in energy spectra on the response of both TLD and OSLD using Burlin Cavity Theory. Energy response correction factors were determined for a range of conditions and compared to measured correction factors with good agreement. When using OSLD for dose measurement in a diagnostic imaging environment, photon energy spectra are often referenced to a therapy-energy or orthovoltage photon beam – commonly 250kVp, Co-60, or even 6MV, where the spectra are substantially different. Appropriate calibration techniques specifically for the OSLD nanoDot in a CT environment have not been presented in the literature; furthermore the dependence of the energy response of the calibration energy has not been emphasized. The results of this work include detailed calibration procedures for CT dosimetry using OSLD, and a full characterization of this dosimetry system in a low-dose, low-energy setting.