Resumo:
INTRODUCTION: Medical schools are charged with providing both a strong basic science and clinical curriculum for their students. In most institutions instruction in performing the core clinical procedures is part of the curriculum, but because of many constraints do medical students practice these procedures as many times as medical students in the past? Several studies have concluded that medical students today feel incompetent to perform basic clinical procedures at the time of graduation. [See PDF for complete abstract]
Resumo:
With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 3%. A pelvis phantom originally designed for use with photon treatments was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was measured. Hounsfield Units (HU) for each phantom material were measured with a CT scanner and compared to the relative stopping power calibration curve. The tissue equivalency for each material was calculated. Two proton treatment plans were created; one which did not correct for material SP differences (Plan 1) and one plan which did correct for SP differences (Plan 2). Film and TLD were loaded into the phantom and the phantom was irradiated 3 times per plan. The measured values were compared to the HU-SP calibration curve and it was found that the stopping powers for the materials could be underestimated by 5-10%. Plan 1 passed the criteria for the TLD and film margins with reproducibility under 3% between the 3 trials. Plan 2 failed because the right-left film dose profile average displacement was -9.0 mm on the left side and 6.0 mm on the right side. Plan 2 was intended to improve the agreements and instead introduced large displacements along the path of the beam. Plan 2 more closely represented the actual phantom composition with corrected stopping powers and should have shown an agreement between the measured and calculated dose within 5%/3mm. The hypothesis was rejected and the pelvis phantom was found to be not suitable to evaluate proton therapy treatment procedures.
Resumo:
The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.
Resumo:
Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within ±5%/3mm with a reproducibility of ±3%. The relative stopping power (RSP) and Hounsfield Units (HU) were measured for potential phantom materials and a human skull was cast in tissue-equivalent Alderson material (RLSP 1.00, HU 16) with anatomical airways and a cylindrical hole for imaging and dosimetry inserts drilled into the phantom material. Two treatment plans, proton passive scattering and proton spot scanning, were created. Thermoluminescent dosimeters (TLDs) and film were loaded into the phantom dosimetry insert. Each treatment plan was delivered three separate times. Each treatment plan passed our 5%/3mm criteria, with a reproducibility of ±3%. The hypothesis was accepted and the phantom was found to be suitable for remote audits of proton therapy treatment facilities.
Resumo:
Monte Carlo simulation has been conducted to investigate parameter estimation and hypothesis testing in some well known adaptive randomization procedures. The four urn models studied are Randomized Play-the-Winner (RPW), Randomized Pôlya Urn (RPU), Birth and Death Urn with Immigration (BDUI), and Drop-the-Loses Urn (DL). Two sequential estimation methods, the sequential maximum likelihood estimation (SMLE) and the doubly adaptive biased coin design (DABC), are simulated at three optimal allocation targets that minimize the expected number of failures under the assumption of constant variance of simple difference (RSIHR), relative risk (ORR), and odds ratio (OOR) respectively. Log likelihood ratio test and three Wald-type tests (simple difference, log of relative risk, log of odds ratio) are compared in different adaptive procedures. ^ Simulation results indicates that although RPW is slightly better in assigning more patients to the superior treatment, the DL method is considerably less variable and the test statistics have better normality. When compared with SMLE, DABC has slightly higher overall response rate with lower variance, but has larger bias and variance in parameter estimation. Additionally, the test statistics in SMLE have better normality and lower type I error rate, and the power of hypothesis testing is more comparable with the equal randomization. Usually, RSIHR has the highest power among the 3 optimal allocation ratios. However, the ORR allocation has better power and lower type I error rate when the log of relative risk is the test statistics. The number of expected failures in ORR is smaller than RSIHR. It is also shown that the simple difference of response rates has the worst normality among all 4 test statistics. The power of hypothesis test is always inflated when simple difference is used. On the other hand, the normality of the log likelihood ratio test statistics is robust against the change of adaptive randomization procedures. ^
Resumo:
Objective. The purpose of this study was to identify the medical issues experienced by Military Working Dogs during their period of deployment in Iraq.^ Design. This study was a retrospective cross-sectional survey based on database and medical record abstraction.^ Population. Military Working Dogs (MWDs) that were deployed to Iraq at any time between 20 March 2003 and 31 December 2007 were the inclusive population of interest. Seven hundred ninety-five (795) MWDs were identified as having been deployed to Iraq during the inclusive dates. Four hundred ninety-six (496) MWDs were identified that had medical events during the deployment period. ^ Procedures. Eligible MWDs were identified through several sources, to include database query, medical record abstraction questionnaire, and medical record abstraction. Demographic information collected for each MWD included tattoo, name, age, gender, breed, Branch of Service, and duty certification. Information on each veterinary/medical clinical event (VCE) was collected. This information was coded, and data entered into a database for organization. Frequency and prevalence information were determined for each category of VCE.^ Results. The top four VCEs experienced by MWDs while deployed in Iraq were gastrohepatic, dermatologic, traumatic injury, and appendicular musculoskeletal issues.^ Conclusions. Training, equipment, and supplies for veterinary personnel who care for the deployed MWDs should be tailored accordingly to suit the identified medical needs of the MWDs. ^
Resumo:
Interim clinical trial monitoring procedures were motivated by ethical and economic considerations. Classical Brownian motion (Bm) techniques for statistical monitoring of clinical trials were widely used. Conditional power argument and α-spending function based boundary crossing probabilities are popular statistical hypothesis testing procedures under the assumption of Brownian motion. However, it is not rare that the assumptions of Brownian motion are only partially met for trial data. Therefore, I used a more generalized form of stochastic process, called fractional Brownian motion (fBm), to model the test statistics. Fractional Brownian motion does not hold Markov property and future observations depend not only on the present observations but also on the past ones. In this dissertation, we simulated a wide range of fBm data, e.g., H = 0.5 (that is, classical Bm) vs. 0.5< H <1, with treatment effects vs. without treatment effects. Then the performance of conditional power and boundary-crossing based interim analyses were compared by assuming that the data follow Bm or fBm. Our simulation study suggested that the conditional power or boundaries under fBm assumptions are generally higher than those under Bm assumptions when H > 0.5 and also matches better with the empirical results. ^
Resumo:
High levels of poverty and unemployment, and low levels of health insurance coverage may pose barriers to obtaining cardiac care by Mexican Americans. We undertook this study to investigate differences in the use of invasive myocardial revascularization procedures received within the 4-month period following hospitalization for a myocardial infarction (MI) between Mexican Americans and non-Hispanic whites in the Corpus Christi Heart Project (CCHP). The CCHP is a population-based surveillance program for hospitalized MI, percutaneous transluminal coronary angioplasty (PTCA), and aortocoronary bypass surgery (ACBS). Medical record data were available for 1706 patients identified over a three-year period. Mexican Americans had significantly lower rates of receiving a PTCA following MI than non-Hispanic Whites (RR: 0.56, 95% CI: 0.44-0.70). No meaningful ethnic difference was seen in the rates of ACBS use. History of PTCA use appeared to interact with ethnicity. Among patients without a history of PTCA use, Mexican Americans were less likely to receive a PTCA than non-Hispanic whites (RR: 0.59; 95% CI: 0.46-0.76). Among patients with a history of PTCA use, however, Mexican Americans were more likely to receive a PTCA than non-Hispanic whites (RR: 1.47; 95% CI: 0.75-2.87).^ Differences in the effectiveness of a first-time PTCA and first-time ACBS between Mexican Americans and non-Hispanic whites in the CCHP were also investigated. Mexican Americans were more likely to receive a 2nd PTCA (RR: 1.56, 95% CI: 1.11-2.17) and suffer a subsequent MI (RR: 1.42, 95% CI: 1.03-1.96) following a first-time PTCA than non-Hispanic whites. No meaningful ethnic differences were found in the rates of death and rates of ACBS following a first-time PTCA. Also, no significant ethnic differences were found in the rates of any of the events following a first-time ACBS. After adjusting for potential demographic, socioeconomic, clinical and angiographic confounders using Cox regression analysis, Mexican Americans were still more likely to receive a 2nd PTCA (HR: 1.38; 95% CI: 0.99-1.93) following a first-time PTCA than non-Hispanic whites. A significant difference in the rates of a subsequent MI following a first-time PTCA persisted (HR: 1.39, 95% CI: 1.01-1.93). (Abstract shortened by UMI.) ^