7 resultados para breastfeeding tools

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any robust quality control program is the determination of significant deviations from standard or baseline conditions, clinicians and vendors often neglect the temporal nature of detector degradation (1). This thesis describes the development and testing of new methods for monitoring detector uniformity. These techniques provide more quantitative, sensitive, and specific feedback to the reviewer so that he or she may be better equipped to identify performance degradation prior to its manifestation in clinical images. The methods exploit the temporal nature of detector degradation and spatially segment distinct regions-of-non-uniformity using multi-resolution decomposition. These techniques were tested on synthetic phantom data using different degradation functions, as well as on experimentally acquired time series floods with induced, progressively worsening defects present within the field-of-view. The sensitivity of conventional, global figures-of-merit for detecting changes in uniformity was evaluated and compared to these new image-space techniques. The image-space algorithms provide a reproducible means of detecting regions-of-non-uniformity prior to any single flood image’s having a NEMA uniformity value in excess of 5%. The sensitivity of these image-space algorithms was found to depend on the size and magnitude of the non-uniformities, as well as on the nature of the cause of the non-uniform region. A trend analysis of the conventional figures-of-merit demonstrated their sensitivity to shifts in detector uniformity. The image-space algorithms are computationally efficient. Therefore, the image-space algorithms should be used concomitantly with the trending of the global figures-of-merit in order to provide the reviewer with a richer assessment of gamma camera detector uniformity characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To develop a greater understanding of the experience—including the thoughts, feelings, and actions—of mothers' initiation and maintenance of lactation within the context of the NICU following the birth of a very preterm infant. ^ Design. Mixed method with dominant focused ethnographic approach. Setting: A 76-bed neonatal intensive care unit in the largest children's hospital located in a large metropolitan city in southeast Texas. ^ Sample. Purposeful sampling resulted in 23 interviews with 14 subjects. ^ Methods. Mixed method design with a dominant qualitative approach combined with a quantitative component to further identify and expand upon the investigation of the population in question. Open-ended semi-structured interviews and fieldwork were used to explore the experience of breastfeeding in the context of the NICU for mothers of very preterm infants. Longitudinal data obtained from each subject included in-depth interviews, demographic and clinical information, milk expression patterns (including pumping frequency, duration, and milk volumes obtained), and scores obtained from the Edinburgh Postpartum Depression Scale (EPDS). ^ Findings. Thematic analysis revealed that mothers of very preterm infants experienced an interruption in the process of becoming a mother, a paradoxical experience related to aspects of their milk expression routines and patterns, and negotiating the NICU environment. Sub-themes of becoming a mother-interrupted included: attribution, separation, connection, and navigation. Additional sub-themes related to the paradoxical experience included: the pump sometimes acting as a wedge or link to the infant; diversionary thoughts/activities during pumping; and perceptions of milk flow/volume. The process of negotiation included the environment, adaptive/maladaptive strategies related to milk expression, motivating factors related to the provision of breast milk, and learning their infant's feeding cues/abilities. EPDS scores did not reveal congruent differences in those mothers scoring high compared to those scoring low. ^ Conclusions. Understanding the experiences of the mothers in this study allows for a better perspective of breastfeeding the very preterm infant in the context of the NICU. Findings from this study validate the difficult and incremental process of attaining maternal identity and the significant burden placed on these women with regards to the provision of breast milk and breastfeeding during their infant's hospitalization. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Giardia lamblia is one of the most common causes of gastrointestinal tract infection among young children worldwide. Yet host protection against this parasite and the effect of infection with Giardia on infant growth are poorly understood. It was hypothesized that among young children, protection against infection with Giardia is afforded by breastfeeding and previous infection with the parasite and further, that infection with Giardia decreases growth velocity. From 4/88 to 4/90, 197 infants in a poor area of Mexico City were followed from 0 to 18 months of age, with stool specimens, symptoms and feeding status data collected weekly. A total of 6,031 stool specimens were tested for Giardia antigen by enzyme-linked immunosorbent assay. There were 1.0 Giardia infections per child-year; 25% were symptomatic and 54% lasted more than 1 month; 94 infants had 1, and 33 had 2 or more infections. Breastfeeding status was coded and analyzed for each child-week of follow up. 91% of study infants were breastfed from birth, 57% at 6 months and 38% at 12 months of age. Rate ratios for non-breastfeeding adjusted for confounding factors were calculated from stratified analyses and the Cox proportional hazards model. Not breastfeeding was a significant risk factor for first infection with Giardia vs. any breastfeeding (adjusted RR = 1.8; 1.1, 2.8) at all ages; a dose response was demonstrated by degree of breastfeeding. The adjusted rate ratio for non-breastfeeding vs. partial breastfeeding was 1.6 (1.03, 2.6) and for non-breastfeeding vs. complete breastfeeding was 4.7 (1.4, 15.9). Among Giardia infected infants, breastfeeding did not protect against diarrheal symptoms or shorten the duration of carriage. First and repeat infections with Giardia did not differ in duration or the percent symptomatic. The analysis of growth and Giardia infection was inconclusive but suggested that a history of Giardia infection might be associated with decreased weight velocity, while an immediate chronic infection might be associated with increased weight velocity. In summary, these data indicate that breastfeeding protects infants against infection with Giardia; provide no evidence of protection against repeat infections resulting from a prior infection and suggest but do not establish that a history of Giardia infection might be associated with decreased growth in young children. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

These Data Management Plans are more comprehensive and complex than in the past. Libraries around the nation are trying to put together tools to help researchers write plans that conform to the new requirements. This session will look at some of these tools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Most studies have looked at breastfeeding practices from the point of view of the maternal behavior only, however in counseling women who choose to breastfeed it is important to be aware of general infant feeding patterns in order to adequately provide information about what to expect. Available literature on the differences in infant breastfeeding behavior by sex is minimal and therefore requires further investigation. Objectives: This study determined if at the age of 2 months there were differences in the amount of breast milk consumed, duration of breastfeeding, and infant satiety by infant sex. It also assessed whether infant sex is an independent predictor of initiation of breastfeeding. Methods: This is a secondary analysis of data obtained from the Infant Feeding Practices Survey II (IFPS II) which was a longitudinal study carried out from May 2005 through June 2007 by the Food and Drug Administration and the Centers for Disease Control and Prevention. The questionnaires asked about demography, prenatal care, mode of delivery, birth weight, infant sex, and breastfeeding patterns. A total of 3,033 and 2,552 mothers completed the neonatal and post-neonatal questionnaires respectively. ^ Results: There was no significant difference in the initiation of breastfeeding by infant sex. About 85% of the male infants initiated breastfeeding compared with 84% of female infants. The odds ratio of ever initiating breastfeeding by male infants was 0.93 but the difference was not significant with a p-value of 0.49. None of the other infant feeding patterns differed by infant gender. ^ Conclusion: This study found no evidence that male infants feed more or that their mothers are more likely to initiate breastfeeding. Each baby is an individual and therefore will have a unique feeding pattern. Based on these findings, the major determining factors for breastfeeding continue to be maternal factors therefore more effort should be invested in promoting breastfeeding among mothers of all ethnic groups and social classes.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryoablation for small renal tumors has demonstrated sufficient clinical efficacy over the past decade as a non-surgical nephron-sparing approach for treating renal masses for patients who are not surgical candidates. Minimally invasive percutaneous cryoablations have been performed with image guidance from CT, ultrasound, and MRI. During the MRI-guided cryoablation procedure, the interventional radiologist visually compares the iceball size on monitoring images with respect to the original tumor on separate planning images. The comparisons made during the monitoring step are time consuming, inefficient and sometimes lack the precision needed for decision making, requiring the radiologist to make further changes later in the procedure. This study sought to mitigate uncertainty in these visual comparisons by quantifying tissue response to cryoablation and providing visualization of the response during the procedure. Based on retrospective analysis of MR-guided cryoablation patient data, registration and segmentation algorithms were investigated and implemented for periprocedural visualization to deliver iceball position/size with respect to planning images registered within 3.3mm with at least 70% overlap and a quantitative logit model was developed to relate perfusion deficit in renal parenchyma visualized in verification images as a result of iceball size visualized in monitoring images. Through retrospective study of 20 patient cases, the relationship between likelihood of perfusion loss in renal parenchyma and distance within iceball was quantified and iteratively fit to a logit curve. Using the parameters from the logit fit, the margin for 95% perfusion loss likelihood was found to be 4.28 mm within the iceball. The observed margin corresponds well with the clinically accepted margin of 3-5mm within the iceball. In order to display the iceball position and perfusion loss likelihood to the radiologist, algorithms were implemented to create a fast segmentation and registration module which executed in under 2 minutes, within the clinically-relevant 3 minute monitoring period. Using 16 patient cases, the average Hausdorff distance was reduced from 10.1mm to 3.21 mm with average DSC increased from 46.6% to 82.6% before and after registration.