2 resultados para blue shift energy

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton radiation therapy is gaining popularity because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target while still sparing critical organs distal to the target. However, the high dose-gradient is a double-edged sword: a small shift of the highly conformal high-dose area can cause the target to be substantially under-dosed or the critical organs to be substantially over-dosed. Because of that, large margins are required in treatment planning to ensure adequate dose coverage of the target, which prevents us from realizing the full potential of proton beams. Therefore, it is critical to reduce uncertainties in the proton radiation therapy. One major uncertainty in a proton treatment is the range uncertainty related to the estimation of proton stopping power ratio (SPR) distribution inside a patient. The SPR distribution inside a patient is required to account for tissue heterogeneities when calculating dose distribution inside the patient. In current clinical practice, the SPR distribution inside a patient is estimated from the patient’s treatment planning computed tomography (CT) images based on the CT number-to-SPR calibration curve. The SPR derived from a single CT number carries large uncertainties in the presence of human tissue composition variations, which is the major drawback of the current SPR estimation method. We propose to solve this problem by using dual energy CT (DECT) and hypothesize that the range uncertainty can be reduced by a factor of two from currently used value of 3.5%. A MATLAB program was developed to calculate the electron density ratio (EDR) and effective atomic number (EAN) from two CT measurements of the same object. An empirical relationship was discovered between mean excitation energies and EANs existing in human body tissues. With the MATLAB program and the empirical relationship, a DECT-based method was successfully developed to derive SPRs for human body tissues (the DECT method). The DECT method is more robust against the uncertainties in human tissues compositions than the current single-CT-based method, because the DECT method incorporated both density and elemental composition information in the SPR estimation. Furthermore, we studied practical limitations of the DECT method. We found that the accuracy of the DECT method using conventional kV-kV x-ray pair is susceptible to CT number variations, which compromises the theoretical advantage of the DECT method. Our solution to this problem is to use a different x-ray pair for the DECT. The accuracy of the DECT method using different combinations of x-ray energies, i.e., the kV-kV, kV-MV and MV-MV pair, was compared using the measured imaging uncertainties for each case. The kV-MV DECT was found to be the most robust against CT number variations. In addition, we studied how uncertainties propagate through the DECT calculation, and found general principles of selecting x-ray pairs for the DECT method to minimize its sensitivity to CT number variations. The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT imaging uncertainty, the uncertainty in the mean excitation energy, and SPR variation with proton energy. Additionally, human body tissues were divided into three tissue groups – low density (lung) tissues, soft tissues and bone tissues. The uncertainties were estimated separately because their uncertainties were different under each condition. An estimate of the composite range uncertainty (2s) was determined for three tumor sites – prostate, lung, and head-and-neck, by combining the uncertainty estimates of all three tissue groups, weighted by their proportions along typical beam path for each treatment site. In conclusion, the DECT method holds theoretical advantages in estimating SPRs for human tissues over the current single-CT-based method. Using existing imaging techniques, the kV-MV DECT approach was capable of reducing the range uncertainty from the currently used value of 3.5% to 1.9%-2.3%, but it is short to reach our original goal of reducing the range uncertainty by a factor of two. The dominant source of uncertainties in the kV-MV DECT was the uncertainties in CT imaging, especially in MV CT imaging. Further reduction in beam hardening effect, the impact of scatter, out-of-field object etc. would reduce the Hounsfeld Unit variations in CT imaging. The kV-MV DECT still has the potential to reduce the range uncertainty further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this prospective observational field study was to present a model for measuring energy expenditure among nurses and to determine if there was a difference between the energy expenditure of nurses providing direct care to adult patients on general medical-surgical units in two major metropolitan hospitals and a recommended energy expenditure of 3.0 kcal/minute over 8 hours. One-third of the predicted cycle ergometer VO2max for the study population was used to calculate the recommended energy expenditure.^ Two methods were used to measure energy expenditure among participants during an 8 hour day shift. First, the Energy Expenditure Prediction Program (EEPP) developed by the University of Michigan Center for Ergonomics was used to calculate energy expenditure using activity recordings from observation (OEE; n = 39). The second method used ambulatory electrocardiography and the heart rate-oxygen consumption relationship (HREE; n = 20) to measure energy expenditure. It was concluded that energy expenditure among nurses can be estimated using the EEPP. Using classification systems from previous research, work load among the study population was categorized as "moderate" but was significantly less than (p = 0.021) 3.0 kcal/minute over 8 hours or 1/3 of the predicted VO2max.^ In addition, the relationships between OEE, body-part discomfort (BPCDS) and mental work load (MWI) were evaluated. The relationships between OEE/BPCDS and OEE/MWI were not significant (p = 0.062 and 0.091, respectively). Among the study population, body-part discomfort significantly increased for upper arms, mid-back, lower-back, legs and feet by mid-shift and by the end of the shift, the increase was also significant for neck and thighs.^ The study also provided documentation of a comprehensive list of nursing activities. Among the most important findings were the facts that the study population spent 23% of the workday in a bent posture, walked an average of 3.14 miles, and spent two-thirds of the shift doing activities other than direct patient care, such as paperwork and communicating with other departments. A discussion is provided regarding the ergonomic implications of these findings. ^