7 resultados para biological equivalent dose

em DigitalCommons@The Texas Medical Center


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Advances in radiotherapy have generated increased interest in comparative studies of treatment techniques and their effectiveness. In this respect, pediatric patients are of specific interest because of their sensitivity to radiation induced second cancers. However, due to the rarity of childhood cancers and the long latency of second cancers, large sample sizes are unavailable for the epidemiological study of contemporary radiotherapy treatments. Additionally, when specific treatments are considered, such as proton therapy, sample sizes are further reduced due to the rareness of such treatments. We propose a method to improve statistical power in micro clinical trials. Specifically, we use a more biologically relevant quantity, cancer equivalent dose (DCE), to estimate risk instead of mean absorbed dose (DMA). Our objective was to demonstrate that when DCE is used fewer subjects are needed for clinical trials. Thus, we compared the impact of DCE vs. DMA on sample size in a virtual clinical trial that estimated risk for second cancer (SC) in the thyroid following craniospinal irradiation (CSI) of pediatric patients using protons vs. photons. Dose reconstruction, risk models, and statistical analysis were used to evaluate SC risk from therapeutic and stray radiation from CSI for 18 patients. Absorbed dose was calculated in two ways: with (1) traditional DMA and (2) with DCE. DCE and DMA values were used to estimate relative risk of SC incidence (RRCE and RRMA, respectively) after proton vs. photon CSI. Ratios of RR for proton vs. photon CSI (RRRCE and RRRMA) were then used in comparative estimations of sample size to determine the minimal number of patients needed to maintain 80% statistical power when using DCE vs. DMA. For all patients, we found that protons substantially reduced the risk of developing a second thyroid cancer when compared to photon therapy. Mean RRR values were 0.052±0.014 and 0.087±0.021 for RRRMA and RRRCE, respectively. However, we did not find that use of DCE reduced the number of patents needed for acceptable statistical power (i.e, 80%). In fact, when considerations were made for RRR values that met equipoise requirements and the need for descriptive statistics, the minimum number of patients needed for a micro-clinical trial increased from 17 using DMA to 37 using DCE. Subsequent analyses revealed that for our sample, the most influential factor in determining variations in sample size was the experimental standard deviation of estimates for RRR across the patient sample. Additionally, because the relative uncertainty in dose from proton CSI was so much larger (on the order of 2000 times larger) than the other uncertainty terms, it dominated the uncertainty in RRR. Thus, we found that use of corrections for cell sterilization, in the form of DCE, may be an important and underappreciated consideration in the design of clinical trials and radio-epidemiological studies. In addition, the accurate application of cell sterilization to thyroid dose was sensitive to variations in absorbed dose, especially for proton CSI, which may stem from errors in patient positioning, range calculation, and other aspects of treatment planning and delivery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within ±5%/3mm with a reproducibility of ±3%. The relative stopping power (RSP) and Hounsfield Units (HU) were measured for potential phantom materials and a human skull was cast in tissue-equivalent Alderson material (RLSP 1.00, HU 16) with anatomical airways and a cylindrical hole for imaging and dosimetry inserts drilled into the phantom material. Two treatment plans, proton passive scattering and proton spot scanning, were created. Thermoluminescent dosimeters (TLDs) and film were loaded into the phantom dosimetry insert. Each treatment plan was delivered three separate times. Each treatment plan passed our 5%/3mm criteria, with a reproducibility of ±3%. The hypothesis was accepted and the phantom was found to be suitable for remote audits of proton therapy treatment facilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tumor-specific transplantation antigens (TSTA) are individually distinct neoantigens expressed on the cells of chemically-induced neoplasms. TSTA are operationally defined by immunization of syngeneic mice against challenge with viable tumor cells. Immunization with cell surface or extracted TSTA induces specific resistance to transplanted tumor cells. The biological and biochemical nature of TSTA was investigated in the 3-methylcholanthrene-induced fibrosarcomas of female C3H/HeJ mice, MCA-F and MCA-D. Tumor cell suspensions were extracted by treatment with 3M KCl or 2.5% butanol solutions and the TSTA was partially purified by preparative isoelectric focusing. The isoelectric pH of TSTA purified from 3M KCl extracts was 5.8-6.0, and from butanol extracts was 6.4-6.6. Whereas immunization with 10('5) and 10('6) irradiated tumor cells induces complete rejection of tumor cell challenge over a two-fold-log dose range, immunization with ug quantities within a one-fold-log dose range of extracted TSTA induces only partial resistance to tumor challenge. Reduced immunogenicity of extracted TSTA is hypothesized to result from immunization of mice with insufficiently purified TSTA preparations. The hypothesis predicts that immunization with highly purified TSTA, free from interfering substances, induces complete rejection of tumor challenge over a broad dose range. To test the hypothesis preparative isotachophoresis (pITP) was used to purify TSTA from electrofocused TSTA fractions. Significant purification was achieved, as immunization with 15 pg to 1.5 ug (5 logs) of pITP-purified TSTA extracted from the MCA-F, or with 1 pg to 10 ng (4 logs) of TSTA from the MCA-D tumor induced specific resistance to tumor challenge. Despite 50,000 fold purification of TSTA, immunization induced partial, not complete, rejection of transplanted tumor cells. This suggests a clear dissociation of the immunogenicity and purification of extracted TSTA, indicating that the induction of partial immunity to tumor challenge is an intrinsic property of extracted TSTA.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MEKK2 is an evolutionarily conserved mitogen-activated protein kinase (MAPK) kinase kinase (MAP3K) that controls the MAPK and IKK-NF-κB pathways. The MAPK and IKK pathways are intracellular signaling networks that are crucial for the Toll-like receptor (TLR) mediated innate immunity, cellular stress and many other physiological responses. Members of the MAP3K family are central to the activation of these processes. However, the molecular mechanisms underlying stimuli-mediated MAP3K activation remain largely unknown. In this study, we identified a key phosphoserine residue, Ser-519 in MEKK2, and its equivalent site Ser-526 in MEKK3 within their activation loop whose phosphorylation are essential for their optimal activation. Mutation of this regulatory serine to an alanine severely impaired MEKK2 activation and MEKK2 signaling to its downstream targets. To demonstrate that physiological stimuli induce this serine phosphorylation, we generated an antibody that specifically recognizes the phosphorylated serine residue. We found that many, but not all, of the MAPK agonists, including the TLR ligands, growth factors, cytokines and cellular stresses, induced this regulatory serine phosphorylation in MEKK2, suggesting an involvement of MEKK2 in the activation of the MAPK cascade leading to different cellular responses. We further investigated the specific role of MEKK2 in LPS/TLR4 signaling by using MEKK2−/− mice. We found that MEKK2 was selectively required for LPS-induced ERK1/2 activation, but not JNK, p38 or NF-κB activation. We also found that MEKK2 was involved in TLR4 dependent induction of proinflammatory cytokines and LPS-induced septic shock. In conclusion, we identified a key regulatory serine residue in the activation loop of MEKK2 whose phosphorylation is a key sensor of receptor- and cellular stress-mediated signals. We also demonstrated that MEKK2 is crucial for TLR4-mediated innate immunity. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Opioids dominate the field of pain management because of their ability to provide analgesia in many medical circumstances. However, side effects including respiratory depression, constipation, tolerance, physical dependence, and the risk of addiction limit their clinical utility. Fear of these side effects results in the under-treatment of acute pain. For many years, research has focused on ways to improve the therapeutic index (the ratio of desirable analgesic effects to undesirable side effects) of opioids. One strategy, combining opioid agonists that bind to different opioid receptor types, may prove successful.^ We discovered that subcutaneous co-administration of a moderately analgesic dose of the mu-opioid receptor (MOR) selective agonist fentanyl (20μg/kg) with subanalgesic doses of the less MOR-specific agonist morphine (100ng/kg-100μg/kg), augmented acute fentanyl analgesia in rats. Parallel [35S]GTPγS binding studies using naïve rat substantia gelatinosa membrane treated with fentanyl (4μM) and morphine (1nM-1pM) demonstrated a 2-fold increase in total G-protein activation. This correlation between morphine-induced augmentation of fentanyl analgesia and G-protein activation led to our proposal that interactions between MORs and DORs underlie opioid-induced augmentation. We discovered that morphine-induced augmentation of fentanyl analgesia and G-protein activity was mediated by DORs. Adding the DOR-selective antagonist naltrindole (200ng/kg, 40nM) at doses that did not alter the analgesic or G-protein activation of fentanyl, blocked increases in analgesia and G-protein activation induced by fentanyl/morphine combinations. Equivalent doses of the MOR-selective antagonist cyprodime (20ng/kg, 4nM) did not block augmentation. Substitution of the DOR-selective agonist SNC80 for morphine yielded similar results, further supporting our conclusion that interactions between MORs and DORs are responsible for morphine-induced augmentation of fentanyl analgesia and G-protein activation. Confocal microscopy of rat substantia gelatinosa showed that changes in the rate of opioid receptor internalization did not account for these effects.^ In conclusion, fentanyl analgesia augmentation by subanalgesic morphine is mediated by increased G-protein activation resulting from functional interactions between MORs and DORs, not changes in MOR internalization. Additional animal and clinical studies are needed to determine whether side effect incidence changes following opioid co-administration. If side effect incidence decreases or remains unchanged, these findings could have important implications for clinical pain treatment. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DEVELOPMENT AND IMPLEMENTATION OF A DYNAMIC HETEROGENEOUS PROTON EQUIVALENT ANTHROPOMORPHIC THORAX PHANTOM FOR THE ASSESSMENT OF SCANNED PROTON BEAM THERAPY by James Leroy Neihart, B.S. APPROVED: ______________________________David Followill, Ph.D. ______________________________Peter Balter, Ph.D. ______________________________Narayan Sahoo, Ph.D. ______________________________Kenneth Hess, Ph.D. ______________________________Paige Summers, M.S. APPROVED: ____________________________ Dean, The University of Texas Graduate School of Biomedical Sciences at Houston DEVELOPMENT AND IMPLEMENTATION OF A DYNAMIC HETEROGENEOUS PROTON EQUIVALENT ANTHROPOMORPHIC THORAX PHANTOM FOR THE ASSESSMENT OF SCANNED PROTON BEAM THERAPY A THESIS Presented to the Faculty of The University of Texas Health Science Center at Houston andThe University of TexasMD Anderson Cancer CenterGraduate School of Biomedical Sciences in Partial Fulfillment of the Requirements for the Degree of MASTER OF SCIENCE by James Leroy Neihart, B.S. Houston, Texas Date of Graduation August, 2013 Acknowledgments I would like to acknowledge my advisory committee members, chair David Followill, Ph.D., Peter Balter, Ph.D, Narayan Sahoo, Ph.D., Kenneth Hess, Ph.D., Paige Summers M.S. and, for their time and effort contributed to this project. I would additionally like to thank the faculty and staff at the PTC-H and the RPC who assisted in many aspects of this project. Falk Pӧnisch, Ph.D. for his breath hold proton therapy treatment expertise, Matt Palmer and Jaques Bluett for proton dosimetry assistance, Matt Kerr for verification plan assistance, Carrie Amador, Nadia Hernandez, Trang Nguyen, Andrea Molineu, Lynda McDonald for TLD and film dosimetry assistance. Finally, I would like to thank my wife and family for their support and encouragement during my research and studies. Development and implementation of a dynamic heterogeneous proton equivalent anthropomorphic thorax phantom for the assessment of scanned proton beam therapy By: James Leroy Neihart, B.S. Chair of Advisory Committee: David Followill, Ph.D Proton therapy has been gaining ground recently in radiation oncology. To date, the most successful utilization of proton therapy is in head and neck cases as well as prostate cases. These tumor locations do not suffer from the resulting difficulties of treatment delivery as a result of respiratory motion. Lung tumors require either breath hold or motion tracking, neither of which have been assessed with an end-to-end phantom for proton treatments. Currently, the RPC does not have a dynamic thoracic phantom for proton therapy procedure assessment. Additionally, such a phantom could be an excellent means of assessing quality assurance of the procedures of proton therapy centers wishing to participate in clinical trials. An eventual goal of this phantom is to have a means of evaluating and auditing institutions for the ability to start clinical trials utilizing proton therapy procedures for lung cancers. Therefore, the hypothesis of this study is that a dynamic anthropomorphic thoracic phantom can be created to evaluate end-to-end proton therapy treatment procedures for lung cancer to assure agreement between the measured and calculated dose within 5% / 5 mm with a reproducibility of 2%. Multiple materials were assessed for thoracic heterogeneity equivalency. The phantom was designed from the materials found to be in greatest agreement. The phantom was treated in an end-to-end treatment four times, which included simulation, treatment planning and treatment delivery. Each treatment plan was delivered three times to assess reproducibility. The dose measured within the phantom was compared to that of the treatment plan. The hypothesis was fully supported for three of the treatment plans, but failed the reproducibility requirement for the most aggressive treatment plan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some patients with Hodgkin lymphoma, carbon-ion therapy would reduce the predicted risk of second cancer incidence in the breast compared with proton therapy. The purpose of this work was to determine whether 4D-optimized carbon-ion therapy would significantly reduce the predicted risk of radiation induced second cancers in the breast for female Hodgkin lymphoma patients while preserving tumor control compared with proton therapy. To achieve our goals, we first investigated whether 4D-optimized carbon beam tracking could reduce dose to volumes outside a moving target compared with 3D-optimized carbon beam tracking while preserving target dose coverage. To understand the reliability of scanned carbon beam tracking, we studied the robustness of dose distributions in thoracic targets to uncertainties in patient motion. Finally, we investigated whether using carbon-ion therapy instead of proton therapy would significantly reduce the predicted risk of second cancer in the breast for a sample of Hodgkin lymphoma patients. We found that 4D-optimized ion beam tracking therapy can reduce the maximum dose to critical structures near a moving target by as much as 53%, compared to 3D-optimized ion beam tracking therapy. We validated these findings experimentally using a scanned carbon ion synchrotron and a motion phantom. We found scanned carbon beam tracking to be sensitive to a number of motion uncertainties, most notably phase delays in tracking, systematic spatial errors, and interfractional motion changes. Our findings indicate that a lower risk of second cancer in the breast might be expected for some Hodgkin lymphoma patients using carbon-ion therapy instead of proton therapy. For our reference scenario, we found the ratio of risk to be 0.77 ± 0.35 for radiogenic breast cancer after carbon-ion therapy versus proton therapy. Our findings were dependent on the RBE values for tumor induction and the radiosensitivity of breast tissue, as well as the physical dose distribution.