2 resultados para biofuel heating system manufacturers

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bacterial pathogens such as enterotoxigenic Escherichia coli, Salmonella, and Campylobacter spp. are associated with up to 80% of diarrheal illness to travelers from developed countries to developing countries. In order to study acute gastrointestinal diseases, researchers from developed countries such as the United States rely on transporting clinical specimens from the developing countries to laboratories in the U.S. in transport media systems. There are few commercially available transport media systems cited in the literature or designated by transport system manufacturers for the transport of enteric bacteria. Therefore a laboratory-based study was conducted to assess three commercial available transport media systems, two gel swabs and one liquid vial, to determine the most appropriate for the maintenance and recovery of common enteric bacterial pathogens. A total of 13 bacterial enteropathogens were recovered from 25°C and 4°C storage temperatures at time points up to 21 days. The results demonstrated that the gel swab and liquid vial transport systems performed similarly for all isolates at both temperatures. All three transport media systems struggled to maintain the isolates at recoverable concentrations when stored at 4°C and it is recommended that isolates be stored at 25°C in transport media systems. Lastly, swab transport systems are recommend for transport since they are small and easy to pack, resist leakage, and are less expensive than similarly performing liquid vial transport media systems.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study assessed if hospital-wide implementation of a needleless intravenous connection system reduces the number of reported percutaneous injuries, overall and those specifically due to intravenous connection activities.^ Incidence rates were compared before and after hospital-wide implementation of a needleless intravenous system at two hospitals, a full service general hospital and a pediatric hospital. The years 1989-1991 were designated as pre-implementation and 1993 was designated as post-implementation. Data from 1992 were not included in the effectiveness evaluation to allow employees to become familiar with use of the new device. The two hospitals showed rate ratios of 1.37 (95% CI = 1.22-1.54, p $\le$.0001) and 1.63 (95% CI = 1.34-1.97, p $\le$.0001), or a 27.1% and a 38.6% reduction in overall injury rate, respectively. Rate ratios for intravenous connection injuries were 2.67 (95% CI = 1.89-3.78, p $\le$.0001) and 3.35 (95% CI = 1.87-6.02, p $\le$.0001), or a 62.5% and a 69.9% reduction in injury rate, respectively. Rate ratios for all non-intravenous connection injuries were calculated to control for factors other than device implementation that may have been operating to reduce the injury rate. These rate ratios were lower, 1.21 and 1.44, demonstrating the magnitude of injury reduction due to factors other than device implementation. It was concluded that the device was effective in reduction of numbers of reported percutaneous injuries.^ Use-effectiveness of the system was also assessed by a survey of randomly selected device users to determine satisfaction with the device, frequency of use and barriers to use. Four hundred seventy-eight surveys were returned for a response rate of 50.9%. Approximately 94% of respondents at both hospitals expressed satisfaction with the needleless system and recommended continued use. The survey also revealed that even though over 50% of respondents report using the device "always" or "most of the time" for intravenous medication administration, flushing lines, and connecting secondary intravenous lines, needles were still being used for these same activities. Compatibility, accessibility and other technical problems were reported as reasons for using needles for these activities. These problems must be addressed, by both manufacturers and users, before the needleless system will be effective in prevention of all intravenous connection injuries. ^