2 resultados para axial rotation

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Hox gene products are transcription factors involved in specifying regional identity along the anteroposterior body axis. In Drosophila, where these genes are known as HOM-C (Homeotic-complex) genes and where they have been most extensively studied, they are expressed in restricted domains along the anteroposterior axis with different anterior limits. Genetic analysis of a large number of gain- and loss-of-function alleles of these genes has revealed that these genes are important in specifying segmental identity at their anterior limits of expression. Furthermore, there is a functional dominance of posterior genes over anterior genes, such that posterior genes can dominantly specify their developmental programs in spite of the expression of more anterior genes in the same segment. In the mouse, there are four clusters of HOM-C genes, called Hox genes. Thus, there may be up to four genes, called paralogs, that are more highly homologous to each other and to their Drosophila homolog than they are to the other mouse Hox genes. The single mutants for two paralogous genes, hoxa-4 and hoxd-4, presented in this dissertation, are similar to several other mouse Hox mutants in that they show partial, incompletely penetrant homeotic transformations of vertebrae at their anterior limit of expression. These mutants were then bred with hoxb-4 mutants (Ramirez-Solis, et al. 1993) to generate the three possible double mutant combinations as well as the triple mutant. The skeletal phenotypes of these group 4 Hox compound mutants displayed clear alterations in regional identity, such that a nearly complete transformation towards the morphology of the first cervical vertebra occurs. These results suggest a certain degree of functional redundancy among paralogous genes in specifying regional identity. Furthermore, there was a remarkable dose-dependent increase in the number of vertebrae transformed to a first cervical vertebra identity, including the second through the fifth cervical vertebrae in the triple mutant. Thus, these genes are required in a larger anteroposterior domain than is revealed by the single mutant phenotypes alone, such that multiple mutations in these genes result in transformations of vertebrae that are not at their anterior limit of expression. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate hemodynamic responses to lateral rotation. ^ Design: Time-series within a randomized controlled trial pilot study. ^ Setting: A medical intensive care unit (ICU) and a medical-surgical ICU in two tertiary care hospitals. ^ Patients: Adult patients receiving mechanical ventilation. ^ Interventions: Two-hourly manual or continuous automated lateral rotation. ^ Measurements and Main Results: Heart rate (HR) and arterial pressure were sampled every 6 seconds for > 24 hours, and pulse pressure (PP) was computed. Turn data were obtained from a turning flow sheet (manual turn) or with an angle sensor (automated turn). Within-subject ensemble averages were computed for HR, mean arterial pressure (MAP), and PP across turns. Sixteen patients were randomized to either the manual (n = 8) or automated (n = 8) turn. Three patients did not complete the study due to hemodynamic instability, bed malfunction or extubation, leaving 13 patients (n = 6 manual turn and n = 7 automated turn) for analysis. Seven patients (54%) had an arterial line. Changes in hemodynamic variables were statistically significant increases ( p < .05), but few changes were clinically important, defined as ≥ 10 bpm (HR) or ≥ 10 mmHg (MAP and PP), and were observed only in the manual-turn group. All manual-turn patients had prolonged recovery to baseline in HR, MAP and PP of up to 45 minutes (p ≤ .05). No significant turning-related periodicities were found for HR, MAP, or PP. Cross-correlations between variables showed variable lead-lag relations in both groups. A statistically, but not clinically, significant increase in HR of 3 bpm was found for the manual-turn group in the back compared with the right lateral position ( F = 14.37, df = 1, 11, p = .003). ^ Conclusions: Mechanically ventilated critically ill patients experience modest hemodynamic changes with manual lateral rotation. A clinically inconsequential increase in HR, MAP, and PP may persist for up to 45 minutes. Automated lateral rotation has negligible hemodynamic effects. ^