7 resultados para artifact
em DigitalCommons@The Texas Medical Center
Resumo:
DCE-MRI is an important technique in the study of small animal cancer models because its sensitivity to vascular changes opens the possibility of quantitative assessment of early therapeutic response. However, extraction of physiologically descriptive parameters from DCE-MRI data relies upon measurement of the vascular input function (VIF), which represents the contrast agent concentration time course in the blood plasma. This is difficult in small animal models due to artifacts associated with partial volume, inflow enhancement, and the limited temporal resolution achievable with MR imaging. In this work, the development of a suite of techniques for high temporal resolution, artifact resistant measurement of the VIF in mice is described. One obstacle in VIF measurement is inflow enhancement, which decreases the sensitivity of the MR signal to the presence of contrast agent. Because the traditional techniques used to suppress inflow enhancement degrade the achievable spatiotemporal resolution of the pulse sequence, improvements can be achieved by reducing the time required for the suppression. Thus, a novel RF pulse which provides spatial presaturation contemporaneously with the RF excitation was implemented and evaluated. This maximizes the achievable temporal resolution by removing the additional RF and gradient pulses typically required for suppression of inflow enhancement. A second challenge is achieving the temporal resolution required for accurate characterization of the VIF, which exceeds what can be achieved with conventional imaging techniques while maintaining adequate spatial resolution and tumor coverage. Thus, an anatomically constrained reconstruction strategy was developed that allows for sampling of the VIF at extremely high acceleration factors, permitting capture of the initial pass of the contrast agent in mice. Simulation, phantom, and in vivo validation of all components were performed. Finally, the two components were used to perform VIF measurement in the murine heart. An in vivo study of the VIF reproducibility was performed, and an improvement in the measured injection-to-injection variation was observed. This will lead to improvements in the reliability of quantitative DCE-MRI measurements and increase their sensitivity.
Resumo:
Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any robust quality control program is the determination of significant deviations from standard or baseline conditions, clinicians and vendors often neglect the temporal nature of detector degradation (1). This thesis describes the development and testing of new methods for monitoring detector uniformity. These techniques provide more quantitative, sensitive, and specific feedback to the reviewer so that he or she may be better equipped to identify performance degradation prior to its manifestation in clinical images. The methods exploit the temporal nature of detector degradation and spatially segment distinct regions-of-non-uniformity using multi-resolution decomposition. These techniques were tested on synthetic phantom data using different degradation functions, as well as on experimentally acquired time series floods with induced, progressively worsening defects present within the field-of-view. The sensitivity of conventional, global figures-of-merit for detecting changes in uniformity was evaluated and compared to these new image-space techniques. The image-space algorithms provide a reproducible means of detecting regions-of-non-uniformity prior to any single flood image’s having a NEMA uniformity value in excess of 5%. The sensitivity of these image-space algorithms was found to depend on the size and magnitude of the non-uniformities, as well as on the nature of the cause of the non-uniform region. A trend analysis of the conventional figures-of-merit demonstrated their sensitivity to shifts in detector uniformity. The image-space algorithms are computationally efficient. Therefore, the image-space algorithms should be used concomitantly with the trending of the global figures-of-merit in order to provide the reviewer with a richer assessment of gamma camera detector uniformity characteristics.
Resumo:
This dissertation presents evidence to support the hypothesis that cytoplasmic malate dehydrogenase (MDH-1) is the enzyme in humans which catalyzes the reduction of aromatic alpha-keto acids in the presence of NADH, and the enzyme which has been described in the literature as aromatic alpha-keto acid reductase (KAR; E.C. 1.1.1.96) is actually a secondary activity of cytoplasmic malate dehydrogenase.^ Purified MDH and purified KAR have the same molecular weight, subunit structure, heat-inactivation profile and tissue distribution. After starch gel electrophoresis, and using p-hydroxyphenylpyruvic acid (HPPA) as substrate, KAR activity co-migrates with MDH-1 in all species studied except some marine animals. Inhibition with malate, the end-product of malate dehydrogenase, substantially reduces or totally eliminates KAR activity. Purified cytoplasmic MDH from human erythrocytes has an alpha-keto acid reductase activity with identical mobility. All electrophoretic variants of MDH-1 seen in the fresh-water bony fish Xiphophorus, the amphibians Rana and humans exhibited identical variation for KAR, and the two traits co-segregated in the small group of offspring from one Rana heterozygote studied. Both enzymes show almost no electrophoretic variation among humans from many ethnic groups, and among several inbred strains of mice both MDH-s and KAR co-migrate with no variation. MDH-1 and KAR in mouse and Chinese hamster fibroblasts show identical mobility differences between species. Antisera raised against purified chicken cytoplasmic MDH totally inhibited both MDH-1 and KAR in chickens and humans. Mitochondrial MDH from tissue homogenates has no detectable KAR activity but purified MDH-2 does.^ The previous claim that the gene for KAR is on human chromosome 12 is disputed because both MDH-1 and LDH bands appear with slightly different mobility approximately midway between the human and hamster controls in somatic cell hybrid studies, and the meaning of this artifact is discussed. ^
Resumo:
The PROPELLER (Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction) magnetic resonance imaging (MRI) technique has inherent advantages over other fast imaging methods, including robust motion correction, reduced image distortion, and resistance to off-resonance effects. These features make PROPELLER highly desirable for T2*-sensitive imaging, high-resolution diffusion imaging, and many other applications. However, PROPELLER has been predominantly implemented as a fast spin-echo (FSE) technique, which is insensitive to T2* contrast, and requires time-inefficient signal averaging to achieve adequate signal-to-noise ratio (SNR) for many applications. These issues presently constrain the potential clinical utility of FSE-based PROPELLER. ^ In this research, our aim was to extend and enhance the potential applications of PROPELLER MRI by developing a novel multiple gradient echo PROPELLER (MGREP) technique that can overcome the aforementioned limitations. The MGREP pulse sequence was designed to acquire multiple gradient-echo images simultaneously, without any increase in total scan time or RF energy deposition relative to FSE-based PROPELLER. A new parameter was also introduced for direct user-control over gradient echo spacing, to allow variable sensitivity to T2* contrast. In parallel to pulse sequence development, an improved algorithm for motion correction was also developed and evaluated against the established method through extensive simulations. The potential advantages of MGREP over FSE-based PROPELLER were illustrated via three specific applications: (1) quantitative T2* measurement, (2) time-efficient signal averaging, and (3) high-resolution diffusion imaging. Relative to the FSE-PROPELLER method, the MGREP sequence was found to yield quantitative T2* values, increase SNR by ∼40% without any increase in acquisition time or RF energy deposition, and noticeably improve image quality in high-resolution diffusion maps. In addition, the new motion algorithm was found to improve the performance considerably in motion-artifact reduction. ^ Overall, this work demonstrated a number of enhancements and extensions to existing PROPELLER techniques. The new technical capabilities of PROPELLER imaging, developed in this thesis research, are expected to serve as the foundation for further expanding the scope of PROPELLER applications. ^
Resumo:
Introduction. Investigations into the shortcomings of current intracavitary brachytherapy (ICBT) technology has lead us to design an Anatomically Adaptive Applicator (A3). The goal of this work was to design and characterize the imaging and dosimetric capabilities of this device. The A3 design incorporates a single shield that can both rotate and translate within the colpostat. We hypothesized that this feature, coupled with specific A3 component construction materials and imaging techniques, would facilitate artifact-free CT and MR image acquisition. In addition, by shaping the delivered dose distribution via the A3 movable shield, dose delivered to the rectum will be less compared to equivalent treatments utilizing current state-of-the-art ICBT applicators. ^ Method and materials. A method was developed to facilitate an artifact-free CT imaging protocol that used a "step-and-shoot" technique: pausing the scanner midway through the scan and moving the A 3 shield out of the path of the beam. The A3 CT imaging capabilities were demonstrated acquiring images of a phantom that positioned the A3 and FW applicators in a clinically-applicable geometry. Artifact-free MRI imaging was achieved by utilizing MRI-compatible ovoid components and pulse-sequences that minimize susceptibility artifacts. Artifacts were qualitatively compared, in a clinical setup. For the dosimetric study, Monte-Carlo (MC) models of the A3 and FW (shielded and unshielded) applicators were validated. These models were incorporated into a MC model of one cervical cancer patient ICBT insertion, using 192Ir (mHDR v2 source). The A3 shield's rotation and translation was adjusted for each dwell position to minimize dose to the rectum. Superposition of dose to rectum for all A3 dwell sources (4 per ovoid) was applied to obtain a comparison of equivalent FW treatments. Rectal dose-volume histograms (absolute and HDR/PDR biologically effective dose (BED)) and BED to 2 cc (BED2cc ) were determined for all applicators and compared. ^ Results. Using a "step-and-shoot" CT scanning method and MR compliant materials and optimized pulse-sequences, images of the A 3 were nearly artifact-free for both modalities. The A3 reduced BED2cc by 18.5% and 7.2% for a PDR treatment and 22.4% and 8.7% for a HDR treatment compared to treatments delivered using an uFW and sFW applicator, respectively. ^ Conclusions. The novel design of the A3 facilitated nearly artifact-free image quality for both CT and MR clinical imaging protocols. The design also facilitated a reduction in BED to the rectum compared to equivalent ICBT treatments delivered using current, state-of-the-art applicators. ^
Resumo:
Background. In the past two decades, the incidence of thyroid cancer in the United States (US) has been increasing. There has been debate on whether the increase is real or an artifact of improved diagnostic scrutiny. Methods. We linked SEER9 database with 2000 US Census to obtain county-level SES (Socioeconomic Status) and compared thyroid cancer incidence trends between high and low SES counties. Joinpoint analysis was used to assess the thyroid cancer incidence trends. Annual Percentage Changes (APCs) were calculated to evaluate incidence trends. Results . The thyroid cancer incidence in high SES counties increased moderately (APC1=+2.5*, *P<0.05) before late 1990s and dramatically increased (APC2=+6.3*) after late 1990s, whereas incidence in low SES counties increased moderately (APC=+3.5*) during the entire time period (1980–2008). For smaller tumors (≤4cm), the APCs in high and low SES counties are similar to each other before late 1990s, but the incidence in high SES counties increased dramatically after late 1990s while that in low SES counties continued at a moderate increase. For large tumors (>4cm), the incidence trends in high SES counties are similar to those of low SES counties, which had a steady moderate increase. Conclusion. Our findings indicate that enhanced detection likely contributed to the increased thyroid cancer incidence in the past decades but cannot fully explain the increase, suggesting that a true increase also exists. Efforts should be made on identifying the cause of this observed increased incidence as well as more refined/selected screening and prevention measures.^
Resumo:
Manuscript 1: “Conceptual Analysis: Externalizing Nursing Knowledge” We use concept analysis to establish that the report tool nurses prepare, carry, reference, amend, and use as a temporary data repository are examples of cognitive artifacts. This tool, integrally woven throughout the work and practice of nurses, is important to cognition and clinical decision-making. Establishing the tool as a cognitive artifact will support new dimensions of study. Such studies can characterize how this report tool supports cognition, internal representation of knowledge and skills, and external representation of knowledge of the nurse. Manuscript 2: “Research Methods: Exploring Cognitive Work” The purpose of this paper is to describe a complex, cross-sectional, multi-method approach to study of personal cognitive artifacts in the clinical environment. The complex data arrays present in these cognitive artifacts warrant the use of multiple methods of data collection. Use of a less robust research design may result in an incomplete understanding of the meaning, value, content, and relationships between personal cognitive artifacts in the clinical environment and the cognitive work of the user. Manuscript 3: “Making the Cognitive Work of Registered Nurses Visible” Purpose: Knowledge representations and structures are created and used by registered nurses to guide patient care. Understanding is limited regarding how these knowledge representations, or cognitive artifacts, contribute to working memory, prioritization, organization, cognition, and decision-making. The purpose of this study was to identify and characterize the role a specific cognitive artifact knowledge representation and structure as it contributed to the cognitive work of the registered nurse. Methods: Data collection was completed, using qualitative research methods, by shadowing and interviewing 25 registered nurses. Data analysis employed triangulation and iterative analytic processes. Results: Nurse cognitive artifacts support recall, data evaluation, decision-making, organization, and prioritization. These cognitive artifacts demonstrated spatial, longitudinal, chronologic, visual, and personal cues to support the cognitive work of nurses. Conclusions: Nurse cognitive artifacts are an important adjunct to the cognitive work of nurses, and directly support patient care. Nurses need to be able to configure their cognitive artifact in ways that are meaningful and support their internal knowledge representations.