12 resultados para anatomical records

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The "EMR Tutorial" is designed to be a bilingual online physician education environment about electronic medical records. After iterative assessment and redesign, the tutorial was tested in two groups: U.S. physicians and Mexican medical students. Split-plot ANOVA revealed significantly different pre-test scores in the two groups, significant cognitive gains for the two groups overall, and no significant difference in the gains made by the two groups. Users rated the module positively on a satisfaction questionnaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We have carried out an extensive qualitative research program focused on the barriers and facilitators to successful adoption and use of various features of advanced, state-of-the-art electronic health records (EHRs) within large, academic, teaching facilities with long-standing EHR research and development programs. We have recently begun investigating smaller, community hospitals and out-patient clinics that rely on commercially-available EHRs. We sought to assess whether the current generation of commercially-available EHRs are capable of providing the clinical knowledge management features, functions, tools, and techniques required to deliver and maintain the clinical decision support (CDS) interventions required to support the recently defined "meaningful use" criteria. METHODS: We developed and fielded a 17-question survey to representatives from nine commercially available EHR vendors and four leading internally developed EHRs. The first part of the survey asked basic questions about the vendor's EHR. The second part asked specifically about the CDS-related system tools and capabilities that each vendor provides. The final section asked about clinical content. RESULTS: All of the vendors and institutions have multiple modules capable of providing clinical decision support interventions to clinicians. The majority of the systems were capable of performing almost all of the key knowledge management functions we identified. CONCLUSION: If these well-designed commercially-available systems are coupled with the other key socio-technical concepts required for safe and effective EHR implementation and use, and organizations have access to implementable clinical knowledge, we expect that the transformation of the healthcare enterprise that so many have predicted, is achievable using commercially-available, state-of-the-art EHRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Early detection of colorectal cancer through timely follow-up of positive Fecal Occult Blood Tests (FOBTs) remains a challenge. In our previous work, we found 40% of positive FOBT results eligible for colonoscopy had no documented response by a treating clinician at two weeks despite procedures for electronic result notification. We determined if technical and/or workflow-related aspects of automated communication in the electronic health record could lead to the lack of response. METHODS: Using both qualitative and quantitative methods, we evaluated positive FOBT communication in the electronic health record of a large, urban facility between May 2008 and March 2009. We identified the source of test result communication breakdown, and developed an intervention to fix the problem. Explicit medical record reviews measured timely follow-up (defined as response within 30 days of positive FOBT) pre- and post-intervention. RESULTS: Data from 11 interviews and tracking information from 490 FOBT alerts revealed that the software intended to alert primary care practitioners (PCPs) of positive FOBT results was not configured correctly and over a third of positive FOBTs were not transmitted to PCPs. Upon correction of the technical problem, lack of timely follow-up decreased immediately from 29.9% to 5.4% (p<0.01) and was sustained at month 4 following the intervention. CONCLUSION: Electronic communication of positive FOBT results should be monitored to avoid limiting colorectal cancer screening benefits. Robust quality assurance and oversight systems are needed to achieve this. Our methods may be useful for others seeking to improve follow-up of FOBTs in their systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic imaging results remains a challenge. We hypothesized that an electronic medical record (EMR) that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. METHODS: We studied critical imaging alert notifications in the outpatient setting of a tertiary care Department of Veterans Affairs facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (ie, health care practitioner/provider [HCP] opened the message for viewing) within 2 weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted HCPs to determine timely follow-up actions (eg, ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by HCPs analyzed predictors for 2 outcomes: lack of acknowledgment and lack of timely follow-up. RESULTS: Of 123 638 studies (including radiographs, computed tomographic scans, ultrasonograms, magnetic resonance images, and mammograms), 1196 images (0.97%) generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when the ordering HCPs were trainees (odds ratio [OR], 5.58; 95% confidence interval [CI], 2.86-10.89) and when dual-alert (>1 HCP alerted) as opposed to single-alert communication was used (OR, 2.02; 95% CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs 9.7%; P = .22). Risk for lack of timely follow-up was higher with dual-alert communication (OR, 1.99; 95% CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12; 95% CI, 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. CONCLUSIONS: Critical imaging results may not receive timely follow-up actions even when HCPs receive and read results in an advanced, integrated electronic medical record system. A multidisciplinary approach is needed to improve patient safety in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To relate volumetric magnetic resonance imaging (MRI) findings to hypothermia therapy and neurosensory impairments. STUDY DESIGN: Newborns > or =36 weeks' gestation with hypoxic-ischemic encephalopathy who participated in the National Institute of Child Health and Human Development hypothermia randomized trial at our center were eligible. We determined the relationship between hypothermia treatment and usual care (control) to absolute and relative cerebral tissue volumes. Furthermore, we correlated brain volumes with death or neurosensory impairments at 18 to 22 months. RESULT: Both treatment groups were comparable before randomization. Total brain tissue volumes did not differ in relation to treatment assignment. However, relative volumes of subcortical white matter were significantly larger in hypothermia-treated than control infants. Furthermore, relative total brain volumes correlated significantly with death or neurosensory impairments. Relative volumes of the cortical gray and subcortical white matter also correlated significantly with Bayley Scales psychomotor development index. CONCLUSION: Selected volumetric MRI findings correlated with hypothermia therapy and neurosensory impairments. Larger studies using MRI brain volumes as a secondary outcome measure are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cytochrome P450 (P450) monooxygenase system plays a major role in metabolizing a wide variety of xenobiotic as well as endogenous compounds. In performing this function, it serves to protect the body from foreign substances. However, in a number of cases, P450 activates procarcinogens to cause harm. In most animals, the highest level of activity is found in the liver. Virtually all tissues demonstrate P450 activity, though, and the role of the P450 monooxygenase system in these other organs is not well understood. In this project I have studied the P450 system in rat brain; purifying NADPH-cytochrome P450 reductase (reductase) from that tissue. In addition, I have examined the distribution and regulation of expression of reductase and P450 in various anatomical regions of the rat brain.^ NADPH-cytochrome P450 reductase was purified to apparent homogeneity and cytochrome P450 partially purified from whole rat brain. Purified reductase from brain was identical to liver P450 reductase by SDS-PAGE and Western blot techniques. Kinetic studies utilizing cerebral P450 reductase reveal Km values in close agreement with those determined with enzyme purified from rat liver. Moreover, the brain P450 reductase was able to function successfully in a reconstituted microsomal system with partially purified brain cytochrome P450 and with purified hepatic P4501A1 as measured by 7-ethoxycoumarin and 7-ethoxyresorufin O-deethylation. These results indicate that the reductase and P450 components may interact to form a competent drug metabolism system in brain tissue.^ Since the brain is not a homogeneous organ, dependent upon the well orchestrated interaction of numerous parts, pathology in one nucleus may have a large impact upon its overall function. Hence, the anatomical distribution of the P450 monooxygenase system in brain is important in elucidating its function in that organ. Related to this is the regulation of P450 expression in brain. In order to study these issues female rats--both ovariectomized and not--were treated with a number of xenobiotic compounds and sex steroids. The brains from these animals were dissected into 8 discrete regions and the presence and relative level of message for P4502D and reductase determined using polymerase chain reaction. Results of this study indicate the presence of mRNA for reductase and P4502D isoforms throughout the rat brain. In addition, quantitative PCR has allowed the determination of factors affecting the expression of message for these enzymes. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have shown that short-term sensitization of the Aplysia siphon-withdrawal reflex circuit results in multiple sites of change in synaptic efficacy. In this dissertation I have used a realistic modeling approach (using an integrate-and-fire scheme), in conjunction with electrophysiological experiments, to evaluate the contribution of each site of plasticity to the sensitized response.^ This dissertation contains a detailed description of methodology for the construction of the model circuit, consisting of the LFS motor neurons and ten interneurons known to convey excitatory input to them. The model replicates closely the natural motor neuron firing response to a brief tactile stimulus.^ The various circuit elements have different roles for producing circuit output. For example, the sensory connections onto the motor neuron are important for the production of the phasic response, while the polysynaptic interneuronal connections are important for producing the tonic response.^ The multiple sites of plasticity that produce changes in circuit output also have specialized roles. Presynaptic facilitation of the sensory neuron to LFS connection enhances only the phasic component of the motor neuron firing response. The sensory neuron to interneuron connections primarily enhance the tonic component of the motor neuron firing response. Also, the L29 posttetanic potentiation and the L30 presynaptic inhibition primarily enhance the tonic component of the motor neuron firing response. Finally, the information content at the various sites of plasticity can shift with changes in stimulus intensity. This suggests that while the sites of plasticity encoding memory are fixed, the information content at these sites can be dynamic, shifting in anatomical location with changes in the intensity of the test stimulus.^ These sites of plasticity also produce specific changes in the behavioral response. Sensory-LFS plasticity selectively increases the amplitude of the behavioral response, and has no effect on the duration of the behavioral response. Interneuronal plasticity (L29 and L30) affects both the amplitude and duration of the behavioral response. Other sensory plasticity also affect both the amplitude and duration of the behavioral response, presumably by increasing the recruitment of the interneurons, which provide all of the effect on duration of the behavioral response. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate ascertainment of risk factors and disease status is vital in public health research for proper classification of research subjects. The two most common ways of obtaining this data is by self-report and review of medical records (MRs). South Texas Women’s Health Project was a case-control study looking at interrelationships between hormones, diet, and body size and breast cancer among Hispanic women 30-79 years of age. History of breast cancer, diabetes mellitus (DM) and use of DM medications was ascertained from a personal interview. At the time of interview, the subject identified her major health care providers and signed the medical records release form, which was sent to the designated providers. The MRs were reviewed to confirm information obtained from the interview.^ Aim of this study was to determine the sensitivity and specificity between MRs and personal interview in diagnosis of breast cancer, DM and DM treatment. We also wanted to assess how successful our low-cost approach was in obtaining pertinent MRs and what factors influenced the quality of MR or interview data. Study sample was 721 women with both self-report and MR data available by June 2007. Overall response rate for MR requests was 74.5%. MRs were 80.9% sensitive and 100% specific in confirming breast cancer status. Prevalence of DM was 22.7% from the interviews and 16% from MRs. MRs did not provide definite information about DM status of 53.6% subjects. Sensitivity and specificity of MRs for DM status was 88.9% and 90.4% respectively. Disagreement on DM status from the two sources was seen in 15.9% subjects. This discordance was more common among older subjects, those who were married and were predominantly Spanish speaking. Income and level of education did not have a statistically significantly association with this disagreement.^ Both self-report and MRs underestimate the prevalence of DM. Relying solely on MRs leads to greater misclassification than relying on self-report data. MRs have good to excellent specificity and thus serve as a good tool to confirm information obtained from self-report. Self-report and MRs should be used in a complementary manner for accurate assessment of DM and breast cancer status.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine, for penetrating injuries (gunshot, stab) of the chest/abdomen, the impact on fatality of treatment in trauma centers and shock trauma units compared with general hospitals. Medical records of all cases of penetrating injury limited to chest/abdomen and admitted to and discharged from 7 study facilities in Baltimore city 1979-1980 (n = 581) were studied: 4 general hospitals (n = 241), 2 area-wide trauma centers (n = 298), and a shock trauma unit (n = 42). Emergency center and transferred cases were not studied. Anatomical injury severity, measured by modified Injury Severity Score (mISS), was a significant prognostic factor for death, as were cardiovascular shock (SBP $\le$ 70), injury type (gunshot vs stab), and ambulance/helicopter (vs other) transport. All deaths occurred in cases with two or more prognostic factors. Unadjusted relative risks of death compared with general hospitals were 4.3 (95% confidence interval = 2.2, 8.4) for shock trauma and 0.8 (0.4, 1.7) for trauma centers. Controlling for prognostic factors by logistic regression resulted in these relative risks: shock trauma 4.0 (0.7, 22.2), and trauma centers 0.8 (0.2, 3.2). Factors significantly associated with increased risk had the following relative risks by multiple logistic regression: SBP $\le$ 70 (RR = 40.7 (11.0, 148.7)), highest mISS (42 (7.7, 227)), gunshot (8.4 (2.1, 32.6)), and ambulance/helicopter transport (17.2 (1.3, 228.1)). Controlling for age, race, and gender did not alter results significantly. Actual deaths compared with deaths predicted from a multivariable model of general-hospital cases showed 3.7 more than predicted deaths in shock trauma (SMR = 1.6 (0.8, 2.9)) and 0.7 more than predicted deaths in area-wide trauma centers (SMR = 1.05 (0.6, 1.7)). Selection bias due to exclusion of transfers and emergency center cases, and residual confounding due to insufficient injury information, may account for persistence of adjusted high case fatality in shock trauma. Studying all cases prospectively, including emergency center and transferred cases, is needed. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Traditional patient-specific IMRT QA measurements are labor intensive and consume machine time. Calculation-based IMRT QA methods typically are not comprehensive. We have developed a comprehensive calculation-based IMRT QA method to detect uncertainties introduced by the initial dose calculation, the data transfer through the Record-and-Verify (R&V) system, and various aspects of the physical delivery. Methods: We recomputed the treatment plans in the patient geometry for 48 cases using data from the R&V, and from the delivery unit to calculate the “as-transferred” and “as-delivered” doses respectively. These data were sent to the original TPS to verify transfer and delivery or to a second TPS to verify the original calculation. For each dataset we examined the dose computed from the R&V record (RV) and from the delivery records (Tx), and the dose computed with a second verification TPS (vTPS). Each verification dose was compared to the clinical dose distribution using 3D gamma analysis and by comparison of mean dose and ROI-specific dose levels to target volumes. Plans were also compared to IMRT QA absolute and relative dose measurements. Results: The average 3D gamma passing percentages using 3%-3mm, 2%-2mm, and 1%-1mm criteria for the RV plan were 100.0 (σ=0.0), 100.0 (σ=0.0), and 100.0 (σ=0.1); for the Tx plan they were 100.0 (σ=0.0), 100.0 (σ=0.0), and 99.0 (σ=1.4); and for the vTPS plan they were 99.3 (σ=0.6), 97.2 (σ=1.5), and 79.0 (σ=8.6). When comparing target volume doses in the RV, Tx, and vTPS plans to the clinical plans, the average ratios of ROI mean doses were 0.999 (σ=0.001), 1.001 (σ=0.002), and 0.990 (σ=0.009) and ROI-specific dose levels were 0.999 (σ=0.001), 1.001 (σ=0.002), and 0.980 (σ=0.043), respectively. Comparing the clinical, RV, TR, and vTPS calculated doses to the IMRT QA measurements for all 48 patients, the average ratios for absolute doses were 0.999 (σ=0.013), 0.998 (σ=0.013), 0.999 σ=0.015), and 0.990 (σ=0.012), respectively, and the average 2D gamma(5%-3mm) passing percentages for relative doses for 9 patients was were 99.36 (σ=0.68), 99.50 (σ=0.49), 99.13 (σ=0.84), and 98.76 (σ=1.66), respectively. Conclusions: Together with mechanical and dosimetric QA, our calculation-based IMRT QA method promises to minimize the need for patient-specific QA measurements by identifying outliers in need of further review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was development of a method of estimating nutrient availability in populations as approximated by supermarket purchase records. Demographic information describing 12,516 panel households was obtained from a marketing and advertising program operated by H. E. Butt Grocery Company of San Antonio, Texas. A non-probability sample of 2,161 households meeting expenditure criteria was selected and all purchases of dairy products for this sample of households were organized into a database constructed to facilitate the retrieval, aggregation, and analysis of dairy product purchases and their nutrient contents. Two hypotheses were tested: (1) no difference would be found between Hispanic and non-Hispanic purchases of dairy product categories during the study period and (2) no difference would be found between Hispanic and non-Hispanic purchases of nutrients contained in those dairy products during the thirteen-week study period.^ Food purchase records were used to estimate nutrient exposure on a weekly, per capita basis for Hispanic and non-Hispanic households by linking some 40,000 dairy purchase Universal Product code (UPC) numbers with food composition values contained in USDA Handbook 8-1. Results of this study suggest Hispanic sample households consistently purchased fewer dairy products than did non-Hispanic sample households and consequently had fewer nutrients available from dairy purchases. While weekly expenditures for dairy products among the sample households remained relatively constant during the study period, shifts in the types of dairy products purchased were observed. The effect of ethnicity on dairy product and nutrient purchases was significant over the thirteen-week period. A database consisting of customer, household, and purchase information can be developed to successfully associate food item UPC numbers with a standard reference of food composition to estimate nutrient availability in a population over extended periods of time. ^