3 resultados para alpaca top and yarn

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy. Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the DVHs from each plan iteration. We used a tumor control probability (TCP) model to calculate losses in tumor control resulting from not accounting for the couch top and rails. We also verified dose measurements in a phantom. Results: Failure to account for the treatment couch and rails resulted in clinically unacceptable dose and volume coverage losses to the target for both IMRT and RapidArc. The couch caused average dose losses (relative to plans that ignored the couch) to the prostate of 4.2% and 2.0% for IMRT with the rails out and in, respectively, and 3.2% and 2.9% for RapidArc with the rails out and in, respectively. On average, the percentage of the target covered by the prescribed dose dropped to 35% and 84% for IMRT (rails out and in, respectively) and to 18% and 17% for RapidArc (rails out and in, respectively). The TCP was also reduced by as much as 10.5% (6.3% on average). Dose and volume coverage losses for IMRT plans were primarily due to the rails, while the imaging couch top contributed most to losses for RapidArc. Both the couch top and rails contribute to dose and coverage losses that can render plans clinically unacceptable. A follow-up study we performed found that the less attenuating unipanel mesh couch top available with the Varian Exact couch does not cause a clinically impactful loss of dose or coverage for IMRT but still causes an unacceptable loss for RapidArc. Conclusions: Both the imaging couch top and rails contribute to dose and coverage loss to a degree that, if included, would prevent the plan from meeting clinical planning criteria. Therefore, the imaging and mesh couch tops and rails should be accounted for in Arc Therapy and the imaging couch and rails only in IMRT treatment planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Public schools are a key forum in the fight for child health because of the opportunities they present for physical activity and fitness surveillance. However, because schools are evaluated and funded on the basis of standardized academic performance rather than physical activity, empirical research evaluating the connections between fitness and academic performance is needed to justify curriculum allocations to physical activity. ^ Methods. Analyses were based on a convenience sample of 315,092 individually-matched standardized academic (TAKS™) and fitness (FITNESSGRAM®) test records collected by 13 Texas school districts under state mandates. We categorized each fitness result in quintiles by age and gender and used a mixed effects regression model to compare the academic performance of the top and bottom fitness groups for each fitness test and grade level combination. ^ Results. All fitness variables except BMI showed significant, positive associations with academic performance after sociodemographic covariate adjustments, with effect sizes ranging from 0.07 (95% CI: 0.05,0.08) in girls trunklift-TAKS reading to 0.34 (0.32,0.35) in boys cardiovascular-TAKS math. Cardiovascular fitness showed the largest inter-quintile difference in TAKS score (32-75 points), followed by curl-ups. After an additional adjustment for BMI and curl-ups, cardiovascular associations peaked in 8th-9 th grades (maximum inter-quintile difference 142 TAKS points; effect size 0.75 (0.69,0.82) for 8th grade girls math) and showed dose-response characteristics across quintiles (p<0.001 for both genders and outcomes). BMI analysis demonstrated limited, non-linear association with academic performance after adjustment for sociodemographic, cardiovascular fitness and curl-up variables. Low-BMI Hispanic high school boys showed significantly lower TAKS scores than the moderate (but not high) BMI group. High-BMI non-Hispanic white high school girls showed significantly lower scores than the moderate (but not low) BMI group. ^ Conclusions. In this study, fitness was strongly and significantly related to academic performance. Cardiovascular fitness showed a distinct dose-response association with academic performance independent of other sociodemographic and fitness variables. The association peaked in late middle to early high school. The independent association of BMI to academic performance was only found in two sub-groups and was non-linear, with both low and high BMI posing risk relative to moderate BMI but not to each other. In light of our findings, we recommend that policymakers consider PE mandates in middle-high school and require linkage of academic and fitness records to facilitate longitudinal surveillance. School administrators should consider increasing PE time in pursuit of higher academic test scores, and PE practitioners should emphasize cardiovascular fitness over BMI reduction.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human a2 -macroglobulin ( a2 M; homotetramer, Mr 720 kDa) is an essential scavenger of proteinases in the serum. Each of its four subunits has a ‘bait region’, with cleavage sequences for almost all endo-proteinases, an unusual thiol ester moiety and a receptor-binding domain (RBD). Bait region cleavage in native a2 M ( a2 M-N) by a proteinase results in rapid thiol ester breakage, with a large-scale structural transformation, in which a2 M uniquely entraps the proteinase in a cage-like structure and exposes receptor-binding domains for rapid endocytosis. Transformed a2 M ( a2 M-TR) contains up to two proteinases, which remain active to small substrates. 3-D electron microscopy is optimally suited to study this unusual structural change at resolutions near (1/30) Å−1. ^ The structural importance of the thiol esters was demonstrated by a genetically-engineered a2 M, with the cysteines involved in thiol ester formation mutated to serines, which appeared structurally homologous to a2 M-TR. This demonstrates that the four highly labile thiol esters alone maintain the a2 M-N structure, while the ‘closed trap’ formed by a2 M-TR is a more stable structural form. ^ Half-transformed a2 M ( a2 M-HT), with cleaved bait regions and thiol esters in only two of its four subunits, provides an important structural link between a2 M-N and a2 M-TR. A comparison with a2 M-N showed the two proteinase-entrapping domains were above and below the plane bisecting the long axis. Both a2 M-N and a2 M-TR consist of two dense, oppositely twisted strands with significant interconnections, indicating that the structural change involves a rotation of these strands. In a2 M-HT these strands were partially untwisted with large central openings, revealing the manner in which the proteinase enters the internal cavity of a2 M. ^ In reconstructions of a2 M-N, a2 M-HT and a2 M-TR labeled with a monoclonal Fab, the Fabs were located on distal ends of each constitutive strand, demonstrating an anti-parallel arrangement of the subunits. Separation between the top and bottom pairs of Fabs was nearly the same on all structures, but the pairs were rotated about the long axis. Taken together, these results indicate that upon proteinase cleavage the two strands in a2 M-N separate. The proteinase enters the structure, while the strands re-twist to encage it. In a2 M-TR, which displays receptor-binding arms, more than two subunits are transformed as strands in the transformed half of a2 M-HT were not separated. ^