5 resultados para X-rays: stars
em DigitalCommons@The Texas Medical Center
Resumo:
In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could serve a dual function as a fiducial marker for image guided radiation therapy (IGRT) treatment if it could be modified to be visible on x-rays. In this study, modifications to the MOSFET dosimeter were made to increase its visibility for IGRT treatment. To test whether the modifications hindered the dosimeter’s ability to accurately measure and transmit dose information, the energy dependence, angular dependence and wireless read range of the modified dosimeter were measured and compared to unmodified dosimeters. It was found that the modified dosimeter performed as well as the unmodified dosimeter while also being suitable for use as a fiducial marker for IGRT treatment.
Resumo:
Background. About a third of the world’s population is infected with tuberculosis (TB) with sub-Saharan Africa being the worst hit. Uganda is ranked 16th among the countries with the biggest TB burden. The burden in children however has not been determined. The burden of TB has been worsened by the advent of HIV and TB is the leading cause of mortality in HIV infected individuals. Development of TB disease can be prevented if TB is diagnosed during its latent stage and treated with isoniazid. For over a century, latent TB infection (LTBI) was diagnosed using the Tuberculin Skin Test (TST). New interferon gamma release assays (IGRA) have been approved by FDA for the diagnosis of LTBI and adult studies have shown that IGRAs are superior to the TST but there have been few studies in children especially in areas of high TB and HIV endemicity. ^ Objective. The objective of this study was to examine whether the IGRAs had a role in LTBI diagnosis in HIV infected children in Uganda. ^ Methods. Three hundred and eighty one (381) children were recruited at the Baylor College of Medicine-Bristol Meyers Squibb Children’s Clinical Center of Excellence at Mulago Hospital, Kampala, Uganda between March and August 2010. All the children were subjected to a TST and T-SPOT ®.TB test which was the IGRA chosen for this study. Sputum examination and chest x-rays were also done to rule out active TB. ^ Results. There was no statistically significant difference between the tests. The agreement between the two assays was 95.9% and the kappa statistic was 0.7 (95% CI: 0.55–0.85, p-value<0.05) indicating a substantial or good agreement. The TST was associated with older age and higher weight for age z-scores but the T-SPOT®. TB was not. Both tests were associated with history of taking anti-retroviral therapy (ART). ^ Conclusion. Before promoting use of IGRAs in children living in HIV/TB endemic countries, more research needs to be done. ^
Resumo:
In this study, an attempt is made to evaluate certain parameters that might indicate the beginning of a certain fibrogenic activity in the lung parenchyma, even before such changes become visible on the chest x-ray. The hypothesis is that studies such as certain bronchoalveolar immunological characteristics and Gallium-67 lung scans may be more sensitive indicators of parenchymal lung damage in response to asbestos inhalation than conventional radiographic criteria. If so, then in those cases where the criteria for the diagnosis of asbestosis lack the presence of parenchymal changes, it would be unwise to deny the diagnosis unless further investigations, such as the bronchoalveolar lavage fluid analysis and the Gallium-67 lung scan techniques, are made available.^ Four groups of individuals have been included in this study. The volunteer group showing no history of asbestos exposure with normal chest x-rays has been used as a normal healthy comparison group. The other three groups are all asbestos-exposed but differ as to their findings in the chest radiographs. One has parenchymal changes (0/1 or more, ILO Classification), the second has no parenchymal but pleural changes, and the third has neither.^ The most significant laboratory parameter for bronchoalveolar lavage, in this study, is that of Neutrophils (PMNs). All three asbestos-exposed groups showed no differences when compared with each other, while such differences were statistically significant when such groups were separately compared with the normal comparison group. A similar finding existed also when the Helper: Suppressor T-Cell ratios were compared, and found to be higher in all the asbestos-exposed groups.^ Another sensitive test is that of Gallium-67 lung scan. This was found to be positive in some patients where parenchymal changes were absent. Even in some of those who showed neither parenchymal nor pleural changes in their chest x-ray showed positive test results. Such changes indicate a state of an underlying pathogenic process that is still undetectable by conventional radiography. This highly recommends the future application of such tests for the early detection of active pulmonary disease, especially in those who show no parenchymal changes in their chest x-rays. (Abstract shortened with permission of author.) ^
Resumo:
Background. Necrotizing pneumonia is generally considered a rare complication of pneumococcal pneumonia in adults. We systematically studied the incidence of necrotizing changes in adult patients with pneumococcal pneumonia, and examined the severity of infection, the role of causative serotype and the association with bacteremia. ^ Methods. We used a data base of all pneumococcal infections identified at our medical center between 2000 and 2010. Original readings of chest X-rays (CXR) and computerized tomography (CT) were noted. All images were then reread independently by 2 radiologists. The severity of disease was assessed using the SMART-COP scoring system. ^ Results. There were 351 cases of pneumococcal pneumonia. Necrosis was reported in no original CXR readings and 6 of 136 (4.4%) CTs. With re-reading, 8 of 351 (2.3%) CXR and 15 of 136 (11.0%) CT had necrotizing changes. Overall, these changes were found in 23 of 351 (6.6%, 95% CI 4.0 - 9.1) patients. The incidence of bacteremia and the admitting SMART-COP scores were similar in patients with and without necrosis (P=1.00 and P=0.32, respectively). Type 3 pneumococcus was more commonly isolated from patients with than from patients without necrotizing pneumonia (P=0.05), but a total of 10 serotypes were identified among 16 cases in which the organism was available for typing. ^ Conclusions. Necrotizing changes in the lungs were seen in 6.6% (95% CI 4.0 - 9.1) of a large series of adults with pneumococcal pneumonia. Patients with necrosis were not more likely to have bacteremia or more severe disease. Type 3 pneumococcus was commonly implicated, but 9 other serotypes were also identified.^
Resumo:
The clinical advantage for protons over conventional high-energy x-rays stems from their unique depth-dose distribution, which delivers essentially no dose beyond the end of range. In order to achieve it, accurate localization of the tumor volume relative to the proton beam is necessary. For cases where the tumor moves with respiration, the resultant dose distribution is sensitive to such motion. One way to reduce uncertainty caused by respiratory motion is to use gated beam delivery. The main goal of this dissertation is to evaluate the respiratory gating technique in both passive scattering and scanning delivery mode. Our hypothesis for the study was that optimization of the parameters of synchrotron operation and respiratory gating can lead to greater efficiency and accuracy of respiratory gating for all modes of synchrotron-based proton treatment delivery. The hypothesis is tested in two specific aims. The specific aim #1 is to assess the efficiency of respiratory-gated proton beam delivery and optimize the synchrotron operations for the gated proton therapy. A simulation study was performed and introduced an efficient synchrotron operation pattern, called variable Tcyc. In addition, the simulation study estimated the efficiency in the respiratory gated scanning beam delivery mode as well. The specific aim #2 is to assess the accuracy of beam delivery in respiratory-gated proton therapy. The simulation study was extended to the passive scattering mode to estimate the quality of pulsed beam delivery to the residual motion for several synchrotron operation patterns with the gating technique. The results showed that variable Tcyc operation can offer good reproducible beam delivery to the residual motion at a certain phase of the motion. For respiratory gated scanning beam delivery, the impact of motion on the dose distributions by scanned beams was investigated by measurement. The results showed the threshold for motion for a variety of scan patterns and the proper number of paintings for normal and respiratory gated beam deliveries. The results of specific aims 1 and 2 provided supporting data for implementation of the respiratory gating beam delivery technique into both passive and scanning modes and the validation of the hypothesis.