3 resultados para Watt-hour meter
em DigitalCommons@The Texas Medical Center
Resumo:
Children with spina bifida meningomyelocele (SBM) are impaired relative to controls in terms of discriminating strong-meter and weak-meter rhythms, so congenital cerebellar dysmorphologies that affect rhythmic movements also disrupt rhythm perception. Cerebellar parcellations in children with SBM showed an abnormal configuration of volume fractions in cerebellar regions important for rhythm function: a smaller inferior-posterior lobe, and larger anterior and superior-posterior lobes.
Resumo:
Background. Research investigating symptom management in patients with chronic obstructive pulmonary disease (COPD) largely has been undertaken assuming the homeostatic construct, without regard to potential roles of circadian rhythms. Temporal relations among dyspnea, fatigue, peak expiratory flow rate (PEFR) and objective measures of activity/rest have not been reported in COPD. ^ Objectives. The specific aims of this study were to (1) explore the 24-hour patterns of dyspnea, fatigue, and PEFR in subjects with COPD; (2) examine the relations among dyspnea, fatigue, and PEFR in COPD; and (3) examine the relations among objective measures of activity/rest and dyspnea, fatigue, and PEFR in COPD. ^ Methods. The repeated-measures design involved 10 subjects with COPD who self-assessed dyspnea and fatigue by 100 mm visual analog scales, and PEFR by peak flow meter in their home 5 times a day for 8 days. Activity/rest was measured by wrist actigraphy. Single and population mean cosinor analyses and correlations were computed for dyspnea, fatigue, and PEFR; correlations were done among these variables and activity/rest. ^ Results. Circadian rhythms were documented by single cosinor analysis in 40% of the subjects for dyspnea, 60% for fatigue, and 60% for PEFR. The population cosinor analysis of PEFR yielded a significant rhythm (p < .05). The 8-day 24-hour means of dyspnea and fatigue was moderately correlated (r = .48, p < .01). Dyspnea and PEFR, and fatigue and PEFR, were weakly correlated in a negative way (r = −.11, p < .05 and r = −.15, p < .01 respectively). Weak to moderate correlations (r = .12–.34, p < .05) were demonstrated between PEFR and mean activity level measured up to 4 hours before PEFR measurement. ^ Conclusions. The findings suggest that (1) the dyspnea and fatigue experienced by COPD patients are moderately related, (2) there is a weak to modest positive relation between PEFR and activity levels, and (3) temporal variation in lung function may not affect the dyspnea and fatigue experienced by patients with COPD. Further research, examining the relations among dyspnea, fatigue, PEFR, and activity/rest is needed. Replication of this study is suggested with a larger sample size. ^
Resumo:
An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^