5 resultados para Waste water
em DigitalCommons@The Texas Medical Center
Resumo:
The occurrence of waste pharmaceuticals has been identified and well documented in water sources throughout North America and Europe. Many studies have been conducted which identify the occurrence of various pharmaceutical compounds in these waters. This project is an extensive review of the documented evidence of this occurrence published in the scientific literature. This review was performed to determine if this occurrence has a significant impact on the environment and public health. This project and review found that pharmaceuticals such as sex hormone drugs, antibiotic drugs and antineoplastic/cytostatic agents as well as their metabolites have been found to occur in water sources throughout the United States at levels high enough to have noticeable impacts on human health and the environment. It was determined that the primary sources of this occurrence of pharmaceuticals were waste water effluent and solid wastes from sewage treatment plants, pharmaceutical manufacturing plants, healthcare and biomedical research facilities, as well as runoff from veterinary medicine applications (including aquaculture). ^ In addition, current public policies of US governmental agencies such as the Environmental Protection Agency (EPA), Food and Drug Administration (FDA), and Drug Enforcement Agency (DEA) have been evaluated to see if they are doing a sufficient job at controlling this issue. Specific recommendations for developing these EPA, FDA, and DEA policies have been made to mitigate, prevent, or eliminate this issue.^ Other possible interventions such as implementing engineering controls were also evaluated in order to mitigate, prevent and eliminate this issue. These engineering controls include implementing improved current treatment technologies such as the advancement and improvement of waste water treatment processes utilized by conventional sewage treatment and pharmaceutical manufacturing plants. In addition, administrative controls such as the use of “green chemistry” in drug synthesis and design were also explored and evaluated as possible alternatives to mitigate, prevent, or eliminate this issue. Specific recommendations for incorporating these engineering and administrative controls into the applicable EPA, FDA, and DEA policies have also been made.^
Resumo:
A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using $\alpha$/$\beta$ discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen.^ U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-$\ell$ aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi $\ell\sp{-1}$. $\alpha$-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi $\ell\sp-1$ are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain $\sp{234}$U/$\sp{238}$U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation.^ The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross $\alpha$ activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi $\ell\sp{-1}$, with seven samples exceeding the proposed Maximum Contaminant Level of 20 $\mu$g $\ell\sp{-1}$. Four exceeded the proposed activity screening level of 30 pCi $\ell\sp{-1}$. Isotopic ratios ranged from 0.87 to 41.8, while one sample contained $\sp{234}$U activity of 34.6 pCi $\ell\sp{-1}$ in the complete absence of its parent, $\sp{238}$U. U mass in the samples with elevated activity ranged from 0.0 to 103 $\mu$g $\ell\sp{-1}$. A limited test of screening surface and groundwaters for contamination by U from waste sites and natural processes was also successful. ^
Resumo:
The objectives of this research were: to determine the contribution of algae to commonly run water quality variables, to evaluate waste pond micoorganisms' capacity to degrade and accumulate ten EPA priority pollutants, and to determine the environmental fate of those compounds in a laboratory
Resumo:
The efficacy of waste stabilization lagoons for the treatment of five priority pollutants and two widely used commercial compounds was evaluated in laboratory model ponds. Three ponds were designed to simulate a primary anaerobic lagoon, a secondary facultative lagoon, and a tertiary aerobic lagoon. Biodegradation, volatilization, and sorption losses were quantified for bis(2-chloroethyl) ether, benzene, toluene, naphthalene, phenanthrene, ethylene glycol, and ethylene glycol monoethyl ether. A statistical model using a log normal transformation indicated biodegradation of bis(2-chloroethyl) ether followed first-order kinetics. Additionally, multiple regression analysis indicated biochemical oxygen demand was the water quality variable most highly correlated with bis(2-chloroethyl) ether effluent concentration. ^
Resumo:
NORM (Naturally Occurring Radioactive Material) Waste Policies for the nation's oil and gas producing states have been in existence since the 1980's, when Louisiana was the first state to develop a NORM regulatory program in 1989. Since that time, expectations for NORM Waste Policies have evolved, as Health, Safety, Environment, and Social responsibility (HSE & SR) grows increasingly important to the public. Therefore, the oil and gas industry's safety and environmental performance record will face challenges in the future, about its best practices for managing the co-production of NORM wastes. ^ Within the United States, NORM is not federally regulated. The U.S. EPA claims it regulates NORM under CERCLA (superfund) and the Clean Water Act. Though, there are no universally applicable regulations for radium-based NORM waste. Therefore, individual states have taken responsibility for developing NORM regulatory programs, because of the potential radiological risk it can pose to man (bone and lung cancer) and his environment. This has led to inconsistencies in NORM Waste Policies as well as a NORM management gap in both state and federal regulatory structures. ^ Fourteen different NORM regulations and guidelines were compared between Louisiana and Texas, the nation's top two petroleum producing states. Louisiana is the country's top crude oil producer when production from its Federal offshore waters are included, and fourth in crude oil production, behind Texas, Alaska, and California when Federal offshore areas are excluded. Louisiana produces more petroleum products than any state but Texas. For these reasons, a comparative analysis between Louisiana and Texas was undertaken to identify differences in their NORM regulations and guidelines for managing, handling and disposing NORM wastes. Moreover, this analysis was undertaken because Texas is the most explored and drilled worldwide and yet appears to lag behind its neighboring state in terms of its NORM Waste Policy and developing an industry standard for handling, managing and disposing NORM. As a result of this analysis, fourteen recommendations were identified.^