16 resultados para URBAN AIR QUALITY

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The airliner cabin environment and its effects on occupant health have not been fully characterized. This dissertation is: (1) A review of airliner environmental control systems (ECSs) that modulate the ventilation, temperature, relative humidity (RH), and barometric pressure (PB) of the cabin environment---variables related to occupant comfort and health. (2) A review and assessment of the methods and findings of key cabin air quality (CAQ) investigations. Several significant deficiencies impede the drawing of inferences about CAQ, e.g., lack of detail about investigative methods, differences in methods between investigations, limited assessment of CAQ variables, small sample sizes, and technological deficiencies of data collection. (3) A comprehensive evaluation of the methods used in the subsequent NIOSH-FAA Airliner CAQ Exposure Assessment Feasibility Study (STUDY) in which this author participated. A number of problems were identified which limit the usefulness of the data. (4) An analysis of the reliable 10-flight STUDY data. Univariate and multivariate methods applied to CO2 (a surrogate for air contaminants), temperature, RH, and PB, in association with percent passenger load, ventilation system, flight duration, airliner body type, and measurement location within the cabin, revealed neither the measured values nor their variability exceeded established health-based exposure limits. Regression analyses suggest CO2, temperature, and RH were affected by percent passenger load. In-flight measurements of CO2 and RH were relatively independent of ventilation system type or flight duration. Cabin temperature was associated with percent passenger load, ventilation system type, and flight duration. (5) A synthesis of the implications of the airliner ECS and cabin O2 environment on occupant health. A model was developed to predict consequences of the airliner cabin pressure altitude 8,000 ft limit and resulting model-estimated PO2 on cardiopulmonary status. Based on the PB, altitude, and environmental data derived from the 10 STUDY flights, the predicted PaO2 of adults with COPD, or elderly adults with or without COPD, breathing ambient cabin air could be < 55 mm Hg (SaO2 < 88%). Reduction in cabin PB found in the STUDY flights could aggravate various medical conditions and require the use of in-flight supplemental O2. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Under the Clean Air Act, Congress granted discretionary decision making authority to the Administrator of the Environmental Protection Agency (EPA). This discretionary authority involves setting standards to protect the public's health with an "adequate margin of safety" based on current scientific knowledge. The Administrator of the EPA is usually not a scientist, and for the National Ambient Air Quality Standard (NAAQS) for particulate matter (PM), the Administrator faced the task of revising a standard when several scientific factors were ambiguous. These factors included: (1) no identifiable threshold below which health effects are not manifested, (2) no biological basis to explain the reported associations between particulate matter and adverse health effects, and (3) no consensus among the members of the Clean Air Scientific Advisory Committee (CASAC) as to what an appropriate PM indicator, averaging period, or value would be for the revised standard. ^ This project recommends and demonstrates a tool, integrated assessment (IA), to aid the Administrator in making a public health policy decision in the face of ambiguous scientific factors. IA is an interdisciplinary approach to decision making that has been used to deal with complex issues involving many uncertainties, particularly climate change analyses. Two IA approaches are presented; a rough set analysis by which the expertise of CASAC members can be better utilized, and a flag model for incorporating the views of stakeholders into the standard setting process. ^ The rough set analysis can describe minimal and maximal conditions about the current science pertaining to PM and health effects. Similarly, a flag model can evaluate agreement or lack of agreement by various stakeholder groups to the proposed standard in the PM review process. ^ The use of these IA tools will enable the Administrator to (1) complete the NAAQS review in a manner that is in closer compliance with the Clean Air Act, (2) expand the input from CASAC, (3) take into consideration the views of the stakeholders, and (4) retain discretionary decision making authority. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indoor Air Quality (IAQ) can have significant implications for health, productivity, job performance, and operating cost. Professional experience in the field of indoor air quality suggests that high expectations (better than nationally established standards) (American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE)) of workplace indoor air quality lead to increase air quality complaints. To determine whether there is a positive association between expectations and indoor air quality complaints, a one-time descriptive and analytical cross-sectional pilot study was conducted. Area Safety Liaisons (n = 330) at University of Texas Health Science Center – Houston were asked to answer a questionnaire regarding their expectations of four workplace indoor air quality indicators i.e., (temperature, relative humidity, carbon dioxide, and carbon monoxide) and if they experienced and reported indoor air quality problems. A chi-square test for independence was used to evaluate associations among the variables of interest. The response rate was 54% (n = 177). Results did not show significant associations between expectation and indoor air quality. However, a greater proportion of Area Safety Liaisons who expected indoor air quality indicators to be better than the established standard experienced greater indoor air quality problems. Similarly, a slightly higher proportion of Area Liaisons who expected indoor air quality indicators to be better than the standard reported greater indoor air quality complaints. ^ The findings indicated that a greater proportion of Area Safety Liaisons with high expectations (conditions that are beyond what is considered normal and acceptable by ASHRAE) experienced greater indoor air quality discomfort. This result suggests a positive association between high expectations and experienced and reported indoor air quality complaints. Future studies may be able to address whether the frequency of complaints and resulting investigations can be reduced through information and education about what are acceptable conditions.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the indoor environment of two different types of dental practices regarding VOCs, PM2.5, and ultrafine particulate concentrations and examine the relationship between specific dental activities and contaminant levels. Method: The indoor environments of two selected dental settings (private practice and community health center) will were assessed in regards to VOCs, PM 2.5, and ultrafine particulate concentrations, as well as other indoor air quality parameters (CO2, CO, temperature, and relative humidity). The sampling duration was four working days for each dental practice. Continuous monitoring and integrated sampling methods were used and number of occupants, frequency, type, and duration of dental procedures or activities recorded. Measurements were compared to indoor air quality standards and guidelines. Results: The private practice had higher CO2, CO, and most VOC concentrations than the community health center, but the community health center had higher PM2.5 and ultrafine PM concentrations. Concentrations of p-dichlorobenzene and PM2.5 exceeded some guidelines. Outdoor concentrations greatly influenced the indoor concentration. There were no significant differences in contaminant levels between the operatory and general area. Indoor concentrations during the working period were not always consistently higher than during the nonworking period. Peaks in particulate matter concentration occurred during root canal and composite procedures.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The federal regulatory regime for addressing airborne toxic pollutants functions fairly well in most of the country. However, it has proved deficient in addressing local risk issues, especially in urban areas with densely concentrated sources. The problem is especially pronounced in Houston, which is home to one of the world's biggest petrochemical complexes and a major port, both located near a large metropolitan center. Despite the fact that local government's role in regulating air toxics is typically quite limited, from 2004-2009, the City of Houston implemented a novel municipality-based air toxics reduction strategy. The initiatives ranged from voluntary agreements to litigation and legislation. This case study considers why the city chose the policy tools it did, how the tools performed relative to the designers' intentions, and how the debate among actors with conflicting values and goals shaped the policy landscape. The city's unconventional approach to controlling hazardous air pollution has not yet been examined rigorously. The case study was developed through reviews of publicly available documents and quasi-public documents obtained through public record requests, as well as interviews with key informants. The informants represented a range of experience and perspectives. They included current and former public officials at the city (including Mayor White), former Texas Commission on Environmental Quality staff, faculty at local universities, industry representatives, and environmental public health advocates. Some of the city's tools were successful in meeting their designers' intent, some were less successful. Ultimately, even those tools that did not achieve their stated purpose were nonetheless successful in bringing attention and resources to the air quality issue. Through a series of pleas and prods, the city managed to draw attention to the problem locally and get reluctant policymakers at higher levels of government to respond. This work demonstrates the potential for local government to overcome limitations in the federal regulatory regime for air toxics control, shifting the balance of local, state, and federal initiative. It also highlights the importance of flexible, cooperative strategies in local environmental protection.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few recent estimates of childhood asthma incidence exist in the literature, although the importance of incidence surveillance for understanding asthma risk factors has been recognized. Asthma prevalence, morbidity and mortality reports have repeatedly shown that low-income children are disproportionately impacted by the disease. The aim of this study was to demonstrate the utility of Medicaid claims data for providing statewide estimates of asthma incidence. Medicaid Analytic Extract (MAX) data for Texas children ages 0-17 enrolled in Medicaid between 2004 and 2007 were used to estimate incidence overall and by age group, gender, race and county of residence. A 13+ month period of continuous enrollment was required in order to distinguish incident from prevalent cases identified in the claims data. Age-adjusted incidence of asthma was 4.26/100 person-years during 2005-2007, higher than reported in other populations. Incidence rates decreased with age, were higher for males than females, differed by race, and tended to be higher in rural than urban areas. With this study, we were able to demonstrate the utility of MAX data for estimating asthma incidence, and create a dataset of incident cases to use in further analysis. ^ In subsequent analyses, we investigated a possible association between ambient air pollutants and incident asthma among Medicaid-enrolled children in Harris County Texas between 2005 and 2007. This population is at high risk for asthma, and living in an area with historically poor air quality. We used a time-stratified case-crossover design and conditional logistic regression to calculate odds ratios, adjusted for weather variables and aeroallergens, to assess the effect of increases in ozone, NO2 and PM2.5 concentrations on risk of developing asthma. Our results show that a 10 ppb increase in ozone was significantly associated with asthma during the warm season (May-October), with the strongest effect seen when a 6-day cumulative lag period was used to compute the exposure metric (OR=1.05, 95% CI, 1.02–1.08). Similar results were seen for NO2 and PM 2.5 (OR=1.07, 95% CI, 1.03–1.11 and OR=1.12, 95% CI, 1.03–1.22, respectively). PM2.5 also had significant effects in the cold season (November-April), 5-day cumulative lag: OR=1.11, 95% CI, 1.00–1.22. When compared with children in the lowest quartile of O3 exposure, the risk for children in the highest quartile was 20% higher. This study indicates that these pollutants are associated with newly-diagnosed childhood asthma in this low-income urban population, particularly during the summer months. ^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Southeast Texas, including Houston, has a large presence of industrial facilities and has been documented to have poorer air quality and significantly higher cancer rates than the remainder of Texas. Given citizens’ concerns in this 4th largest city in the U.S., Mayor Bill White recently partnered with the UT School of Public Health to determine methods to evaluate the health risks of hazardous air pollutants (HAPs). Sexton et al. (2007) published a report that strongly encouraged analytic studies linking these pollutants with health outcomes. In response, we set out to complete the following aims: 1. determine the optimal exposure assessment strategy to assess the association between childhood cancer rates and increased ambient levels of benzene and 1,3-butadiene (in an ecologic setting) and 2. evaluate whether census tracts with the highest levels of benzene or 1,3-butadiene have higher incidence of childhood lymphohematopoietic cancer compared with census tracts with the lowest levels of benzene or 1,3-butadiene, using Poisson regression. The first aim was achieved by evaluating the usefulness of four data sources: geographic information systems (GIS) to identify proximity to point sources of industrial air pollution, industrial emission data from the U.S. EPA’s Toxic Release Inventory (TRI), routine monitoring data from the U.S. EPA Air Quality System (AQS) from 1999-2000 and modeled ambient air levels from the U.S. EPA’s 1999 National Air Toxic Assessment Project (NATA) ASPEN model. Further, once these four data sources were evaluated, we narrowed them down to two: the routine monitoring data from the AQS for the years 1998-2000 and the 1999 U.S. EPA NATA ASPEN modeled data. We applied kriging (spatial interpolation) methodology to the monitoring data and compared the kriged values to the ASPEN modeled data. Our results indicated poor agreement between the two methods. Relative to the U.S. EPA ASPEN modeled estimates, relying on kriging to classify census tracts into exposure groups would have caused a great deal of misclassification. To address the second aim, we additionally obtained childhood lymphohematopoietic cancer data for 1995-2004 from the Texas Cancer Registry. The U.S. EPA ASPEN modeled data were used to estimate ambient levels of benzene and 1,3-butadiene in separate Poisson regression analyses. All data were analyzed at the census tract level. We found that census tracts with the highest benzene levels had elevated rates of all leukemia (rate ratio (RR) = 1.37; 95% confidence interval (CI), 1.05-1.78). Among census tracts with the highest 1,3-butadiene levels, we observed RRs of 1.40 (95% CI, 1.07-1.81) for all leukemia. We detected no associations between benzene or 1,3-butadiene levels and childhood lymphoma incidence. This study is the first to examine this association in Harris and surrounding counties in Texas and is among the first to correlate monitored levels of HAPs with childhood lymphohematopoietic cancer incidence, evaluating several analytic methods in an effort to determine the most appropriate approach to test this association. Despite recognized weakness of ecologic analyses, our analysis suggests an association between childhood leukemia and hazardous air pollution.^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Manufactured housing has been found to have substantial levels of formaldehyde in the indoor air. Because mobile homes are more affordable than conventional housing, there has been a large increase in their use in the U.S. This increase in mobile home use has been substantial in the sunbelt regions such as Texas, where high temperatures and humidities may enhance out-gassing of formaldehyde and other volatile organic compounds from construction and furnishing materials and increase any potential health hazards.^ The influences of environmental, architectural and temporal factors on the presence of indoor formaldehyde and other organic compounds were investigated in conjunction with the Texas Indoor Air Quality Study of manufactured housing. A matched pair of mobile homes, one with electric heating and cooking utilities and the other with propane gas utilities, were used for a series of controlled experiments over a fourteen month period from October, 1982 through November, 1983.^ Over this fourteen month period formaldehyde levels decreased approximately 33%. Daily fluctuations of 20% to 40% were observed even with a constant indoor temperature. An increase in indoor temperature of 8(DEGREES)C doubled the measured formaldehyde concentration. Opening windows resulted in decreases of indoor formaldehyde levels of up to 50%. Studies of the impact of propane as a cooking source showed no increase in formaldehyde levels with stove use.^ The presence and concentration of selected volatile organic compounds is influenced greatest by occupancy. Occupants continually open and close windows and doors, vary the operation and settings (temperature) of air control systems, and vary in their selection of furnishings and use of consumer products, which may act as sources of indoor air contaminants. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sick Building Syndrome is a prevalent problem with patient complaints similar to typical allergy symptoms. Unlike most household allergens, the Asp f 1 allergen is conceivably ubiquitous in the work environment. This project examined levels of the Asp f 1 allergen in office and non-industrial occupational environments, and studied the bioaerosol and dust reservoirs of Aspergillus fumigatus responsible for those levels. ^ Culturable bioaerosols of total mesophilic fungi were sampled with Andersen N6 impactors. Aggressive airborne and bulk dust samples were concurrently collected and assayed for Asp f 1. Bulk dusts were selectively cultured for A. fumigatus. Samples were collected during both wet and dry climatological conditions to examine the possibility of Asp f 1 increases due to fungal growth blooms. ^ Only very low levels of Asp f 1 were detected in relatively few samples. Analysis of wet versus dry period samples showed no differences in Asp f 1 levels, although A. fumigatus counts from dusts did fluctuate significantly with exterior moisture events as did indoor prevalence of total colony forming units. These results indicate that even in the presence of elevated fungal concentrations, levels of Asp f 1 are extremely low. These levels do not correlate with climatological moisture events, despite distinct fungal blooms in the days immediately following those events. Non-industrial office buildings devoid of indoor air quality issues did not demonstrate significant levels or occurrence of Asp f 1 contamination in the geographical region of this study. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Decades of research show that environmental exposure to the chemical benzene is associated with severe carcinogenic, hematoxic and genotoxic effects on the human body. As such, the Environmental Protection Agency (EPA) has designated the chemical as a Hazardous Air Pollutant and prescribed benzene air concentration guidelines that provide cities with an ideal ambient level to protect human health. However, in Houston, Texas, a city home to the top industrial benzene emitters in the US who undoubtedly contribute greatly to the potentially unsafe levels of ambient benzene, regulations beyond the EPA’s unenforceable guidelines are critical to protecting public health. Despite this, the EPA has failed to establish National Ambient Air Quality Standards (NAAQS) for benzene. States are thus left to regulate air benzene levels on their own; in the case of Texas, the Texas Commission on Environmental Quality (TCEQ) and state legislature have failed to proactively develop legally enforceable policies to reduce major source benzene emissions. This inaction continues to exacerbate a public health problem, which may only be solved through a legal framework that restricts preventable benzene emissions to protect human health and holds industrial companies accountable for violations of such regulations and standards. This analysis explores legal barriers that the City of Houston and other relevant agencies currently face in their attempt to demand and bring about such change. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Asthma is the most common chronic disorder in childhood, affecting an estimated 6.2 million children under 18 years (1). The purpose of this study was to look at individual- and community-level characteristics simultaneously to examine and explain the factors that contribute to the use of emergency department services by children 18 years old or less and to determine if there was an association between air quality and ED visits in the same population, from 2005-2007 in Houston/Harris County. Data were collected from the Houston Safety Net Hospital Emergency Department Use Study and the 2000 US Census. Bivariate and multivariate logistic regression models and mixed effects models were used to analyze data that was collected during the study period.^ There were 704,902 ED visits made by children 18 and younger, who were living in Houston from January 1, 2005 to December 31, 2007. Of those, 19,098 had a primary discharge diagnosis of asthma. Asthma ED visits varied by season, with proportions of ED visits for asthma highest from September-December. African-American children were 2.6 (95% CI, 2.43-2.66) times more likely to have an ED visit for asthma compared to White children. Poverty, single parent headed households, and younger age all a greater likelihood of having gone to the ED for asthma treatment. Compared to Whites living in lightly-monitored pollution areas, African-Americans and Hispanics living in heavily monitored areas were 1.15 (95% CI, 1.04-1.28) times more likely to have an ED visit for asthma.^ Race and poverty seem to account for a large portion of the disparities in ED use found among children. This was true even after accounting for multiple individual- and community-level variables. These results suggest that racial disparities in asthma continue to pose risks for African American children, and they point to the need for additional research into potential explanations and remedies. Programs to reduce inappropriate ED use must be sensitive to an array of complex socioeconomic issues within minority and income populations. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Houston region is home to arguably the largest petrochemical and refining complex anywhere. The effluent of this complex includes many potentially hazardous compounds. Study of some of these compounds has led to recognition that a number of known and probable carcinogens are at elevated levels in ambient air. Two of these, benzene and 1,3-butadiene, have been found in concentrations which may pose health risk for residents of Houston.^ Recent popular journalism and publications by local research institutions has increased the interest of the public in Houston's air quality. Much of the literature has been critical of local regulatory agencies' oversight of industrial pollution. A number of citizens in the region have begun to volunteer with air quality advocacy groups in the testing of community air. Inexpensive methods exist for monitoring of ozone, particulate matter and airborne toxic ambient concentrations. This study is an evaluation of a technique that has been successfully applied to airborne toxics.^ This technique, solid phase microextraction (SPME), has been used to measure airborne volatile organic hydrocarbons at community-level concentrations. It is has yielded accurate and rapid concentration estimates at a relatively low cost per sample. Examples of its application to measurement of airborne benzene exist in the literature. None have been found for airborne 1,3-butadiene. These compounds were selected for an evaluation of SPME as a community-deployed technique, to replicate previous application to benzene, to expand application to 1,3-butadiene and due to the salience of these compounds in this community. ^ This study demonstrates that SPME is a useful technique for quantification of 1,3-butadiene at concentrations observed in Houston. Laboratory background levels precluded recommendation of the technique for benzene. One type of SPME fiber, 85 μm Carboxen/PDMS, was found to be a sensitive sampling device for 1,3-butadiene under temperature and humidity conditions common in Houston. This study indicates that these variables affect instrument response. This suggests the necessity of calibration within specific conditions of these variables. While deployment of this technique was less expensive than other methods of quantification of 1,3-butadiene, the complexity of calibration may exclude an SPME method from broad deployment by community groups.^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is scant evidence regarding the associations between ambient levels of combustion pollutants and small for gestational age (SGA) infants. No studies of this type have been completed in the Southern United States. The main objective of the project presented was to determine associations between combustion pollutants and SGA infants in Texas using three different exposure assessments. ^ Birth certificate data that contained information on maternal and infant characteristics were obtained from the Texas Department of State Health Services (TX DSHS). Exposure assessment data for the three aims came from: (1) U.S. Environmental Protection Agency (EPA) National Air Toxics Assessment (NATA), (2) U.S. EPA Air Quality System (AQS), and (3) TX Department of Transportation (DOT), respectively. Multiple logistic regression models were used to determine the associations between combustion pollutants and SGA. ^ For the first study looked at annual estimates of four air toxics at the census tract level in the Greater Houston Area. After controlling for maternal race, maternal education, tobacco use, maternal age, number of prenatal visits, marital status, maternal weight gain, and median census tract income level, adjusted ORs and 95% confidence intervals (CI) for exposure to PAHs (per 10 ng/m3), naphthalene (per 10 ng/m3), benzene (per 1 µg/m3), and diesel engine emissions (per 10 µg/m3) were 1.01 (0.97–1.05), 1.00 (0.99–1.01), 1.01 (0.97–1.05), and 1.08 (0.95–1.23) respectively. For the second study looking at Hispanics in El Paso County, AORs and 95% confidence intervals (CI) for increases of 5 ng/m3 for the sum of carcinogenic PAHs (Σ c-PAHs), 1 ng/m3 of benzo[a]pyrene, and 100 ng/m3 in naphthalene during the third trimester of pregnancy were 1.02 (0.97–1.07), 1.03 (0.96–1.11), and 1.01 (0.97–1.06), respectively. For the third study using maternal proximity to major roadways as the exposure metric, there was a negative association with increasing distance from a maternal residence to the nearest major roadway (Odds Ratio (OR) = 0.96; 95% CI = 0.94–0.97) per 1000 m); however, once adjusted for covariates this effect was no longer significant (AOR = 0.98; 95% CI = 0.96–1.00). There was no association with distance weighted traffic density (DWTD). ^ This project is the first to look at SGA and combustion pollutants in the Southern United States with three different exposure metrics. Although there was no evidence of associations found between SGA and the air pollutants mentioned in these studies, the results contribute to the body of literature assessing maternal exposure to ambient air pollution and adverse birth outcomes. ^