14 resultados para Texture-based volume visualization

em DigitalCommons@The Texas Medical Center


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Quantitative myocardial PET perfusion imaging requires partial volume corrections. METHODS: Patients underwent ECG-gated, rest-dipyridamole, myocardial perfusion PET using Rb-82 decay corrected in Bq/cc for diastolic, systolic, and combined whole cycle ungated images. Diastolic partial volume correction relative to systole was determined from the systolic/diastolic activity ratio, systolic partial volume correction from phantom dimensions comparable to systolic LV wall thicknesses and whole heart cycle partial volume correction for ungated images from fractional systolic-diastolic duration for systolic and diastolic partial volume corrections. RESULTS: For 264 PET perfusion images from 159 patients (105 rest-stress image pairs, 54 individual rest or stress images), average resting diastolic partial volume correction relative to systole was 1.14 ± 0.04, independent of heart rate and within ±1.8% of stress images (1.16 ± 0.04). Diastolic partial volume corrections combined with those for phantom dimensions comparable to systolic LV wall thickness gave an average whole heart cycle partial volume correction for ungated images of 1.23 for Rb-82 compared to 1.14 if positron range were negligible as for F-18. CONCLUSION: Quantitative myocardial PET perfusion imaging requires partial volume correction, herein demonstrated clinically from systolic/diastolic absolute activity ratios combined with phantom data accounting for Rb-82 positron range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The motion of lung tumors during respiration makes the accurate delivery of radiation therapy to the thorax difficult because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, visualize motion, and calculate dose during the planning phase of the radiotherapy process. One image data set that can be created from the 4D-CT acquisition is the maximum-intensity projection (MIP). The MIP can be used as a starting point to define the volume that encompasses the motion envelope of the moving gross target volume (GTV). Because of the close relationship that exists between the MIP and the final target volume, we investigated four MIP data sets created with different methodologies (3 using various 4D-CT sorting implementations, and one using all available cine CT images) to compare target delineation. It has been observed that changing the 4D-CT sorting method will lead to the selection of a different collection of images; however, the clinical implications of changing the constituent images on the resultant MIP data set are not clear. There has not been a comprehensive study that compares target delineation based on different 4D-CT sorting methodologies in a patient population. We selected a collection of patients who had previously undergone thoracic 4D-CT scans at our institution, and who had lung tumors that moved at least 1 cm. We then generated the four MIP data sets and automatically contoured the target volumes. In doing so, we identified cases in which the MIP generated from a 4D-CT sorting process under-represented the motion envelope of the target volume by more than 10% than when measured on the MIP generated from all of the cine CT images. The 4D-CT methods suffered from duplicate image selection and might not choose maximum extent images. Based on our results, we suggest utilization of a MIP generated from the full cine CT data set to ensure a representative inclusive tumor extent, and to avoid geometric miss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tensor based morphometry (TBM) was applied to determine the atrophy of deep gray matter (DGM) structures in 88 relapsing multiple sclerosis (MS) patients. For group analysis of atrophy, an unbiased atlas was constructed from 20 normal brains. The MS brain images were co-registered with the unbiased atlas using a symmetric inverse consistent nonlinear registration. These studies demonstrate significant atrophy of thalamus, caudate nucleus, and putamen even at a modest clinical disability, as assessed by the expanded disability status score (EDSS). A significant correlation between atrophy and EDSS was observed for different DGM structures: (thalamus: r=-0.51, p=3.85 x 10(-7); caudate nucleus: r=-0.43, p=2.35 x 10(-5); putamen: r=-0.36, p=6.12 x 10(-6)). Atrophy of these structures also correlated with 1) T2 hyperintense lesion volumes (thalamus: r=-0.56, p=9.96 x 10(-9); caudate nucleus: r=-0.31, p=3.10 x 10(-3); putamen: r=-0.50, p=6.06 x 10(-7)), 2) T1 hypointense lesion volumes (thalamus: r=-0.61, p=2.29 x 10(-10); caudate nucleus: r=-0.35, p=9.51 x 10(-4); putamen: r=-0.43, p=3.51 x 10(-5)), and 3) normalized CSF volume (thalamus: r=-0.66, p=3.55 x 10(-12); caudate nucleus: r=-0.52, p=2.31 x 10(-7), and putamen: r=-0.66, r=2.13 x 10(-12)). More severe atrophy was observed mainly in thalamus at higher EDSS. These studies appear to suggest a link between the white matter damage and DGM atrophy in MS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Entire issue (large pdf file) Articles include: Behavior Problems of Maltreated Children Receiving In-Home Child Welfare Services. Ferol Mennen, William Meezan, Gino Aisenberg, and Jacquelyn McCroskey Measuring Consumer Satisfaction in Family Preservation Services: Identifying Instrument Domains. Stephen A. Kapp and Rebecca H Vela Intensive In-Home Family-Based Services: Reactions from Consumers and Providers Elaine Walton, and Alfred C. Dodini Coordination of Family Preservation Services in a Rural Community: A Case Study. Richard Freer and Kathleen Wells The Effectiveness of Court Mandated Intervention Versus Voluntary Services in Child Protective Services: Abbreviated Version. Loring Jones, Irene Becker, and Krista F alk

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Entire issue (large pdf file) Articles include: What's Working in Family-Based Services?--or, What's Left to Believe in During a Time of Such Doubt? Roger Friedman The Family Preservation Philosophy and Therapy With Lesbian Clients. Pamela de Santa Parenting Pioneers and Parenting Teams: Strengthening Extended Family Ties in Family Support Programs. Susan Whitelaw Downs Conceptual Bases of the Planning Process in Family Preservation/Family Support State Plans. June Lloyd

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Entire issue (large pdf file) Articles include: A Model for Family Preservation Case Assessment. Kam-fong Monit Cheung, Patrick Leung and Sharon Alpert Behavioral Outcomes of Home-Based Services for Children and Adolescents with Serious Emotional Disorders. Edwin Morris, Lourdes Suarez, John C. Reid A Multi-Faceted, Intensive Family Preservation Program Evaluation. Michael Raschick Targeting Families to Receive Intensive Family Preservation Services: Assessing the Use of Imminent Risk of Placement as a Service Criterion. Elaine Walton and Ramona W. Denby

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mean corpuscular volume, which is an inexpensive and widely available measure to assess, increases in HIV infected individuals receiving zidovudine and stavudine raising the hypothesis that it could be used as a surrogate for adherence.^ The aim of this study was to examine the association between mean corpuscular volume and adherence to antiretroviral therapy among HIV infected children and adolescents aged 0–19 years in Uganda as well as the extent to which changes in mean corpuscular volume predict adherence as determined by virologic suppression.^ The investigator retrospectively reviewed and analyzed secondary data of 158 HIV infected children and adolescents aged 0–19 years who initiated antiretroviral therapy under an observational cohort at the Baylor College of Medicine Children's Foundation - Uganda. Viral suppression was used as the gold standard for monitoring adherence and defined as viral load of < 400 copies/ml at 24 and 48 weeks. ^ Patients were at least 48 weeks on therapy, age 0.2–18.4 years, 54.4% female, 82.3% on zidovudine based regimen, 92% WHO stage III at initiation of therapy, median pre therapy MCV 80.6 fl (70.3–98.3 fl), median CD4% 10.2% (0.3%–28.0%), and mean pre therapy viral load 407,712.9 ± 270,413.9 copies/ml. For both 24 and 48 weeks of antiretroviral therapy, patients with viral suppression had a greater mean percentage change in mean corpuscular volume (15.1% ± 8.4 vs. 11.1% ± 7.8 and 2.3% ± 13.2 vs. -2.7% ± 10.5 respectively). The mean percentage change in mean corpuscular volume was greater in the first 24 weeks of therapy for patients with and without viral suppression (15.1% ± 8.4 vs. 2.3% ± 13.2 and 11.1% ± 7.8 vs. -2.7% ± 10.5 respectively). In the multivariate logistic regression model, percentage change in mean corpuscular volume ≥ 20% was significantly associated with viral suppression (adjusted OR 4.0; CI 1.2–13.3; p value 0.02). The ability of percentage changes in MCV to correctly identify children and adolescents with viral suppression was higher at a cut off of ≥ 20% (90.7%; sensitivity, 31.7%) than at ≥ 9% (82.9%; sensitivity, 78.9%). Negative predictive value was lower at ≥ 20% change (25%; specificity, 84.8%) than at ≥ 9% change (33.3%; specificity, 39.4%).^ Mean corpuscular volume is a useful marker of adherence among children and adolescents with viral suppression. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this dissertation was to determine the initiation and completion rates of adjuvant chemotherapy, its toxicity and the compliance rates of post-treatment surveillance for elderly patients with colon cancer using the linked Surveillance, Epidemiology, and End Results – Medicare database.^ The first study assessed the initiation and completion rate of 5-fluorouracil-based adjuvant chemotherapy and its relationship with patient characteristics. Of the 12,265 patients diagnosed with stage III colon adenocarcinoma in 1991-2005, 64.4% received adjuvant chemotherapy within 3-months after tumor resection and 40% of them completed the treatment. Age, marital status, and comorbidity score were significant predictors for chemotherapy initiation and completion.^ The second study estimated the incidence rate of toxicity-related endpoints among stage III colon adenocarcinoma patients treated with chemotherapy in 1991-2005. Of the 12,099 patients, 63.9% underwent chemotherapy and had volume depletion disorder (3-month cumulative incidence rate [CIR]=9.1%), agranulocytosis (CIR=3.4%), diarrhea (CIR=2.4%), nausea and vomiting (CIR=2.3%). Cox regression analysis confirmed such association (HR=2.76; 95% CI=2.42-3.15). The risk of ischemic heart diseases was slightly associated with chemotherapy (HR=1.08), but significantly among patients aged <75 with no comorbidity (HR=1.70). ^ The third study determined the adherence rate of follow-up cares among patients diagnosed with stage I-III colon adenocarcinoma in 2000 - June 2002. We identified 7,348 patients with a median follow-up of 59 months. The adherence rate was 83.9% for office visits, 29.4% for CEA tests, and 74.3% for colonoscopy. Overall, 25.2% met the recommended post-treatment care. Younger age at diagnosis, white race, married, advanced stage, fewer comorbidities, and chemotherapy use were significantly associated with guideline adherence.^ In conclusions, not all colon cancer patients received chemotherapy. Receiving chemotherapy was associated with increased risk of developing gastrointestinal, hematological and cardiac toxicities. Patients were more likely to comply with the schedule for office visits and colonoscopy but failed in CEA tests. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Traditional patient-specific IMRT QA measurements are labor intensive and consume machine time. Calculation-based IMRT QA methods typically are not comprehensive. We have developed a comprehensive calculation-based IMRT QA method to detect uncertainties introduced by the initial dose calculation, the data transfer through the Record-and-Verify (R&V) system, and various aspects of the physical delivery. Methods: We recomputed the treatment plans in the patient geometry for 48 cases using data from the R&V, and from the delivery unit to calculate the “as-transferred” and “as-delivered” doses respectively. These data were sent to the original TPS to verify transfer and delivery or to a second TPS to verify the original calculation. For each dataset we examined the dose computed from the R&V record (RV) and from the delivery records (Tx), and the dose computed with a second verification TPS (vTPS). Each verification dose was compared to the clinical dose distribution using 3D gamma analysis and by comparison of mean dose and ROI-specific dose levels to target volumes. Plans were also compared to IMRT QA absolute and relative dose measurements. Results: The average 3D gamma passing percentages using 3%-3mm, 2%-2mm, and 1%-1mm criteria for the RV plan were 100.0 (σ=0.0), 100.0 (σ=0.0), and 100.0 (σ=0.1); for the Tx plan they were 100.0 (σ=0.0), 100.0 (σ=0.0), and 99.0 (σ=1.4); and for the vTPS plan they were 99.3 (σ=0.6), 97.2 (σ=1.5), and 79.0 (σ=8.6). When comparing target volume doses in the RV, Tx, and vTPS plans to the clinical plans, the average ratios of ROI mean doses were 0.999 (σ=0.001), 1.001 (σ=0.002), and 0.990 (σ=0.009) and ROI-specific dose levels were 0.999 (σ=0.001), 1.001 (σ=0.002), and 0.980 (σ=0.043), respectively. Comparing the clinical, RV, TR, and vTPS calculated doses to the IMRT QA measurements for all 48 patients, the average ratios for absolute doses were 0.999 (σ=0.013), 0.998 (σ=0.013), 0.999 σ=0.015), and 0.990 (σ=0.012), respectively, and the average 2D gamma(5%-3mm) passing percentages for relative doses for 9 patients was were 99.36 (σ=0.68), 99.50 (σ=0.49), 99.13 (σ=0.84), and 98.76 (σ=1.66), respectively. Conclusions: Together with mechanical and dosimetric QA, our calculation-based IMRT QA method promises to minimize the need for patient-specific QA measurements by identifying outliers in need of further review.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The clinical advantage for protons over conventional high-energy x-rays stems from their unique depth-dose distribution, which delivers essentially no dose beyond the end of range. In order to achieve it, accurate localization of the tumor volume relative to the proton beam is necessary. For cases where the tumor moves with respiration, the resultant dose distribution is sensitive to such motion. One way to reduce uncertainty caused by respiratory motion is to use gated beam delivery. The main goal of this dissertation is to evaluate the respiratory gating technique in both passive scattering and scanning delivery mode. Our hypothesis for the study was that optimization of the parameters of synchrotron operation and respiratory gating can lead to greater efficiency and accuracy of respiratory gating for all modes of synchrotron-based proton treatment delivery. The hypothesis is tested in two specific aims. The specific aim #1 is to assess the efficiency of respiratory-gated proton beam delivery and optimize the synchrotron operations for the gated proton therapy. A simulation study was performed and introduced an efficient synchrotron operation pattern, called variable Tcyc. In addition, the simulation study estimated the efficiency in the respiratory gated scanning beam delivery mode as well. The specific aim #2 is to assess the accuracy of beam delivery in respiratory-gated proton therapy. The simulation study was extended to the passive scattering mode to estimate the quality of pulsed beam delivery to the residual motion for several synchrotron operation patterns with the gating technique. The results showed that variable Tcyc operation can offer good reproducible beam delivery to the residual motion at a certain phase of the motion. For respiratory gated scanning beam delivery, the impact of motion on the dose distributions by scanned beams was investigated by measurement. The results showed the threshold for motion for a variety of scan patterns and the proper number of paintings for normal and respiratory gated beam deliveries. The results of specific aims 1 and 2 provided supporting data for implementation of the respiratory gating beam delivery technique into both passive and scanning modes and the validation of the hypothesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ventricular system is a critical component of the central nervous system (CNS) that is formed early in the developmental stages and remains functional through the lifetime. Changes in the ventricular system can be easily discerned via neuroimaging procedures and most of the time it reflects changes in the physiology of the CNS. In this study we attempted to identify specific genes associated with variation in ventricular volume in humans. Methods. We conducted a genome wide association (GWA) analysis of the volume of the lateral ventricles among 1605 individuals of European ancestry from two community based cohorts, the Genetics of Microangiopathic Brain Injury (GMBI; N=814) and Atherosclerosis Risk in Communities (ARIC; N=791). Significant findings from the analysis were tested for replication in both the cohorts and then meta-analyzed to get an estimate of overall significance. Results. In our GWA analyses, no single nucleotide polymorphism (SNP) reached a genome-wide significance of p<10−8. There were 25 SNPs in GMBI and 9 SNPs in ARIC that reached a threshold of p<10 −5. However, none of the top SNPs from each cohort were replicated in the other. In the meta-analysis, no SNP reached the genome-wide threshold of 5×10−8, but we identified five novel SNPs associated with variation in ventricular volume at the p<10 −5 level. Strongest association was for rs2112536 in an intergenic region on chromosome 5q33 (Pmeta= 8.46×10−7 ). The remaining four SNPs were located on chromosome 3q23 encompassing the gene for Calsyntenin-2 (CLSTN2). The SNPs with strongest association in this region were rs17338555 (Pmeta= 5.28×10 −6), rs9812091 (Pmeta= 5.89×10−6 ), rs9812283 (Pmeta= 5.97×10−6) and rs9833213 (Pmeta= 6.96×10−6). Conclusions. This GWA study of ventricular volumes in the community-based cohorts of European descent identifies potential locus on chromosomes 3 and 5. Further characterization of these loci may provide insights into pathophysiology of ventricular involvement in various neurological diseases.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Entire issue (large pdf file) Articles include: Family Preservation and Support: Past, Present, and Future. Katharine Hooper-Briar,C. Anne Broussard, John Ronnau, and Alvin Sallee An Examination of Treatment Fidelity in an Intensive Family Preservation Program. Marianne Berry Intensive Family Reunification Services: A Conceptual Framework and Case Example. Elaine Walton, Mark W. Fraser, Catherin Harlin, and Robert E. Lewis Intensive Family Preservation Services: Do They Have Any Impact on Family Functioning? Roy W. Rodenhiser, Joseph Chandy, Kazi Ahmed Institutionalizing Intensive Family Preservation Services: A Strategy for Creating Staffing Standards Based on Projections of At-Risk Children from Referral sources. Robert E. Lewis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cryoablation for small renal tumors has demonstrated sufficient clinical efficacy over the past decade as a non-surgical nephron-sparing approach for treating renal masses for patients who are not surgical candidates. Minimally invasive percutaneous cryoablations have been performed with image guidance from CT, ultrasound, and MRI. During the MRI-guided cryoablation procedure, the interventional radiologist visually compares the iceball size on monitoring images with respect to the original tumor on separate planning images. The comparisons made during the monitoring step are time consuming, inefficient and sometimes lack the precision needed for decision making, requiring the radiologist to make further changes later in the procedure. This study sought to mitigate uncertainty in these visual comparisons by quantifying tissue response to cryoablation and providing visualization of the response during the procedure. Based on retrospective analysis of MR-guided cryoablation patient data, registration and segmentation algorithms were investigated and implemented for periprocedural visualization to deliver iceball position/size with respect to planning images registered within 3.3mm with at least 70% overlap and a quantitative logit model was developed to relate perfusion deficit in renal parenchyma visualized in verification images as a result of iceball size visualized in monitoring images. Through retrospective study of 20 patient cases, the relationship between likelihood of perfusion loss in renal parenchyma and distance within iceball was quantified and iteratively fit to a logit curve. Using the parameters from the logit fit, the margin for 95% perfusion loss likelihood was found to be 4.28 mm within the iceball. The observed margin corresponds well with the clinically accepted margin of 3-5mm within the iceball. In order to display the iceball position and perfusion loss likelihood to the radiologist, algorithms were implemented to create a fast segmentation and registration module which executed in under 2 minutes, within the clinically-relevant 3 minute monitoring period. Using 16 patient cases, the average Hausdorff distance was reduced from 10.1mm to 3.21 mm with average DSC increased from 46.6% to 82.6% before and after registration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate calculation of absorbed dose to target tumors and normal tissues in the body is an important requirement for establishing fundamental dose-response relationships for radioimmunotherapy. Two major obstacles have been the difficulty in obtaining an accurate patient-specific 3-D activity map in-vivo and calculating the resulting absorbed dose. This study investigated a methodology for 3-D internal dosimetry, which integrates the 3-D biodistribution of the radionuclide acquired from SPECT with a dose-point kernel convolution technique to provide the 3-D distribution of absorbed dose. Accurate SPECT images were reconstructed with appropriate methods for noise filtering, attenuation correction, and Compton scatter correction. The SPECT images were converted into activity maps using a calibration phantom. The activity map was convolved with an $\sp{131}$I dose-point kernel using a 3-D fast Fourier transform to yield a 3-D distribution of absorbed dose. The 3-D absorbed dose map was then processed to provide the absorbed dose distribution in regions of interest. This methodology can provide heterogeneous distributions of absorbed dose in volumes of any size and shape with nonuniform distributions of activity. Comparison of the activities quantitated by our SPECT methodology to true activities in an Alderson abdominal phantom (with spleen, liver, and spherical tumor) yielded errors of $-$16.3% to 4.4%. Volume quantitation errors ranged from $-$4.0 to 5.9% for volumes greater than 88 ml. The percentage differences of the average absorbed dose rates calculated by this methodology and the MIRD S-values were 9.1% for liver, 13.7% for spleen, and 0.9% for the tumor. Good agreement (percent differences were less than 8%) was found between the absorbed dose due to penetrating radiation calculated from this methodology and TLD measurement. More accurate estimates of the 3-D distribution of absorbed dose can be used as a guide in specifying the minimum activity to be administered to patients to deliver a prescribed absorbed dose to tumor without exceeding the toxicity limits of normal tissues. ^