3 resultados para Silage - Starch and temperature monitoring
em DigitalCommons@The Texas Medical Center
Resumo:
The current standard for temperature sensitive imaging using magnetic resonance (MR) is 2-D, spoiled, fast gradient-echo (fGRE) phase-difference imaging exploiting temperature dependent changes in the proton resonance frequency (PRF). The echo-time (TE) for optimal sensitivity is larger than the typical repetition time (TR) of an fGRE sequence. Since TE must be less than TR in the fGRE sequence, this limits the technique's achievable sensitivity, spatial, and temporal resolution. This adversely affects both accuracy and volume coverage of the measurements. Accurate measurement of the rapid temperature changes associated with pulsed thermal therapies, such as high-intensity focused ultrasound (FUS), at optimal temperature sensitivity requires faster acquisition times than those currently available. ^ Use of fast MR acquisition strategies, such as interleaved echo-planar and spiral imaging, can provide the necessary increase in temporal performance and sensitivity while maintaining adequate signal-to-noise and in-plane spatial resolution. This research explored the adaptation and optimization of several fast MR acquisition methods for thermal monitoring of pulsed FUS thermal therapy. Temperature sensitivity, phase-difference noise and phase-difference to phase-difference-to noise ratio for the different pulse sequences were evaluated under varying imaging parameters in an agar gel phantom to establish optimal sequence parameters for temperature monitoring. The temperature sensitivity coefficient of the gel phantom was measured, allowing quantitative temperature extrapolations. ^ Optimized fast sequences were compared based on the ability to accurately monitor temperature changes at the focus of a high-intensity focused ultrasound unit, volume coverage, and contrast-to-noise ratio in the temperature maps. Operating parameters, which minimize complex phase-difference measurement errors introduced by use of the fast-imaging methods, were established. ^
Resumo:
The combined effects of salinity, temperature and cadmium stress on survival and adaptation through cadmium-binding protein (CdBP) accumulation were studied in the grass shrimp, Palaemonetes pugio. In 96-hour bioassays, shrimp were exposed to zero or one of three levels of cadmium, under one of six different salinity (15, 25, or 35$\perthous$) and temperature (20 or 30$\sp\circ$C) regimes. CdBP concentrations were quantified in survivors from the 24 exposure groups. Salinity and temperature did not affect survivorship unless the shrimp were also exposed to cadmium. Grass shrimp were most sensitive to cadmium at low salinity-high temperature, and least sensitive at high salinity-low temperature. The incidence of cadmium-associated black lesions in gill tissue was influenced by salinity and temperature stress. P. pugio produced a 10,000 dalton metallothionein-like CdBP when exposed to at least 0.1 mg Cd$\sp{2+}$/L for 96 hours. Accumulation of CdBP was increased with increases in the exposure cadmium level, increases in temperature and decreases in salinity, independently and in conjunction with one another. Maximum CdBP concentrations occurred in grass shrimp that survived the salinity-temperature-cadmium conditions creating maximum stress as measured by highest mortality, not necessarily in shrimp exposed to the highest cadmium levels. The potential utility of this method as a monitor of physiological stress in estuarine biota inhabiting metal-polluted environments is discussed. ^
Resumo:
An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^