8 resultados para Salmonella - Contamination
em DigitalCommons@The Texas Medical Center
Resumo:
OBJECTIVES: To detect the influence of blood contamination (BC) on the bond strength (BS) of a self-etching bonding system (SES) to enamel and dentine. METHODS: 25 human molars were longitudinally sectioned on the mesio-distal axis in order to obtain 50 specimens, which were embedded in acrylic resin. At first, the specimens were ground to expose a flat surface of enamel, and a bond strength test was performed. Afterwards, the samples were ground again in order to obtain a flat surface of dentine. Ten groups (total: n=100) were assigned according to substrate (enamel and dentine), step in the bonding sequence when contamination occurred (before the acidic primer and after the bonding resin), and contamination treatment (dry or rinse and dry procedure). Fresh human blood was introduced either before or after SES application (Clearfil SE Bond) and treated with air drying, or by rinsing and drying following application. Composite resin (Filtek Z-250,3M ESPE) was applied as inverted, truncated cured cones that were debonded in tension. RESULTS: The mean tensile BS values (MPa) for enamel/dentine were 19.4/23.0 and 17.1/10.0 for rinse-and-dry treatment (contamination before and after SES, respectively); while the measurements for the dry treatment, 16.2/23.3 and 0.0/0.0 contamination before and after SES, respectively. CONCLUSIONS: It was determined that blood contamination impaired adhesion to enamel and dentine when it occurred after bond light curing. Among the tested contamination treatments, the rinse-and-dry treatment produced the highest bond strength with BC after SES application, but it was not sufficient to recover the BS in the contamination-free group.
Resumo:
The objectives of this research were (1) to study the effect of contact pressure, compression time, and liquid (moisture content of the fabric) on the transfer by sliding contact of non-fixed surface contamination to protective clothing constructed from uncoated, woven fabrics, (2) to study the effect of contact pressure, compression time, and liquid content on the subsequent penetration through the fabric, and (3) to determine if varying the type of contaminant changes the effect of contact pressure, compression time, and liquid content on the transfer by sliding contact and penetration of non-fixed surface contamination. ^ It was found that the combined influence of the liquid (moisture content of the fabric), load (contact pressure), compression time, and their interactions significantly influenced the penetration of all three test agents, sucrose- 14C, triolein-3H, and starch-14C through 100% cotton fabric. The combined influence of the statistically significant main effects and their interactions increased the penetration of triolein- 3H by 32,548%, sucrose-14C by 7,006%, and starch- 14C by 1,900%. ^
Resumo:
Background. Pulsed-field gel electrophoresis (PFGE) is a laboratory technique in which Salmonella DNA banding patterns are used as molecular fingerprints for epidemiologic study for "PFGE clusters". State and national health departments (CDC) use PFGE to detect clusters of related cases and to discover common sources of bacteria in outbreaks. ^ Objectives. Using Houston Department of Health and Human Services (HDHHS) data, the study sought: (1) to describe the epidemiology of Salmonella in Houston, with PFGE subtype as a variable; and (2) to determine whether PFGE patterns and clusters detected in Houston were local appearances of PFGE patterns or clusters that occurred statewide. ^ Methods. During the years 2002 to 2005, the HDHHS collected and analyzed data from routine surveillance of Salmonella. We implemented a protocol, between May 1, 2007 and December 31, 2007, in which PFGE patterns from local cases were sent via e-mail to the Texas Department of State Health Services, to verify whether the local PFGE patterns were also part of statewide clusters. PFGE was performed from 106 patients providing a sample from which Salmonella was isolated in that time period. Local PFGE clusters were investigated, with the enhanced picture obtained by linking local PFGE patterns to PFGE patterns at the state and national level. ^ Results. We found that, during the years 2002 to 2005, there were 66 PFGE clusters, ranging in size from 2 to 22 patients within each cluster. Between different serotypes, there were marked differences in the sizes of PFGE clusters. A common source or risk factor was found in fewer than 5 of the 66 PFGE clusters. With the revised protocol, we found that 19 of 66 local PFGE patterns were indistinguishable from PFGE patterns at Texas DSHS. During the eight months, we identified ten local PFGE clusters with a total of 42 patients. The PFGE pattern for eight of the ten clusters matched the PFGE patterns for cases reported to Texas DSHS from other geographic areas. Five of the ten PFGE patterns matched PFGE patterns for clusters under investigation at PulseNet at the national level. HDHHS epidemiologists identified a mode of transmission in two of the ten local clusters and a common risk factor in a third local cluster. ^ Conclusion. In the extended-study protocol, Houston PFGE patterns were linked to patterns seen at the state and national level. The investigation of PFGE clusters was more efficacious in detecting a common transmission when local data were linked to state and national data. ^
Resumo:
Introduction. Lake Houston serves as a reservoir for both recreational and drinking water for residents of Houston, Texas, and the metropolitan area. The Texas Commission on Environmental Quality (TCEQ) expressed concerns about the water quality and increasing amounts of pathogenic bacteria in Lake Houston (3). The objective of this investigation is to evaluate water quality for the presence of bacteria, nitrates, nitrites, carbon, phosphorus, dissolved oxygen, pH, turbidity, suspended solids, dissolved solids, and chlorine in Cypress Creek. The aims of this project are to analyze samples of water from Cypress Creek and to render a quantitative and graphical representation of the results. The collected information will allow for a better understanding of the aqueous environment in Cypress Creek.^ Methods. Water samples were collected in August 2009 and analyzed in the field and at UTSPH laboratory by spectrophotometry and other methods. Mapping software was utilized to develop novel maps of the sample sites using coordinates attained with the Global Positioning System (GPS). Sample sites and concentrations were mapped using Geographic Information System (GIS) software and correlated with permitted outfalls and other land use characteristic.^ Results. All areas sampled were positive for the presence of total coliform and Escherichia coli (E. coli). The presences of other water contaminants varied at each location in Cypress Creek but were under the maximum allowable limits designated by the Texas Commission on Environmental Quality. However, dissolved oxygen concentrations were elevated above the TCEQ limit of 5.0 mg/L at majority of the sites. One site had near-limit concentration of nitrates at 9.8 mg/L. Land use above this site included farm land, agricultural land, golf course, parks, residential neighborhoods, and nine permitted TCEQ effluent discharge sites within 0.5 miles upstream.^ Significance. Lake Houston and its tributary, Cypress Creek, are used as recreational waters where individuals may become exposed to microbial contamination. Lake Houston also is the source of drinking water for much of Houston/Harris and Galveston Counties. This research identified the presence of microbial contaminates in Cypress Creek above TCEQ regulatory requirements. Other water quality variables measured were in line with TCEQ regulations except for near-limit for nitrate at sample site #10, at Jarvis and Timberlake in Cypress Texas.^
Resumo:
The study was carried out at St. Luke's Episcopal Hospital to evaluate environmental contamination of Clostridium difficile in the infected patient rooms. Samples were collected from the high risk areas and were immediately cultured for the presence of Clostridium difficile . Lack of microbial typing prevented the study of molecular characterization of the Clostridium difficile isolates obtained led to a change in the study hypothesis. The study found a positivity of 10% among 50 Hospital rooms sampled for the presence of Clostridium difficile. The study provided data that led to recommendations that routine environmental sampling be carried in the hospital rooms in which patients with CDAD are housed and that effective environmental disinfection methods are used. The study also recommended molecular typing methods to allow characterization of the CD strains isolated from patients and environmental sampling to determine their type, similarity and origin.^
Resumo:
Outbreaks of diarrhea are common among children in day care centers (DCC). Enteropathogens associated with these outbreaks are spread by the fecal-oral route through contaminated hands or environmental objects. This prospective study was undertaken to determine the prevalence of fecal coliform (FC) contamination in the DCC environment. Ten rooms in 6 DCC housing 121 children $<$2 years of age were studied for 13 weeks. Inanimate objects (1275), toy balls (724), and hands (954) were cultured 1-3 times per week. FC contamination was common during each week of study and was significantly (p $<$ 0.05) greater for objects, toy balls, and hands of children in toddler compared to infant rooms. In 5 rooms in which clothes were worn over diapers, there was a significantly lower prevalence of FC of toy balls (p $<$ 0.005), inanimate objects (p $<$ 0.05), and hands of children (p $<$ 0.001) and caregivers (p $<$ 0.05) when compared to rooms in which overclothes were not worn. Occurrence of diarrhea was significantly associated with increased contamination of caregivers' and children's hands. Using plasmid analysis of trimethoprim (TMP)-resistant Escherichia coli, stool and environmental isolates from individual DCC rooms had the same plasmid patterns, which were unique to each center. In summary, FC of environmental isolates and hands of children and caregivers in DCC is common; toy balls can serve as sentinels of contamination; FC can be significantly decreased by use of clothes worn over diapers; and plasmid analysis of E. coli strains showed the same patterns from stool and environmental isolates. ^
Resumo:
An investigation was undertaken to evaluate the role of fomites in the transmission of diarrhea in day-care centers (DCC) and to elucidate the paths by which enteric organisms spread within this setting.^ During a nine-month period (December 1980-August 1981) extensive culturing of inanimate objects, as well as children and staff was done routinely each month and again repeated during diarrhea outbreaks. Air was sampled from the classrooms and toilets using a Single-Stage Sieve Sampler (Ross Industries, Midland, VA.). Stool samples were collected from both ill and well children and staff in the affected rooms only during outbreaks. Environmental samples were processed for Shigella, salmonella and fecal coliforms while stools were screened for miscellaneous enteropathogens.^ A total of 11 outbreaks occurred in the 5 DCC during the study period. Enteric pathogens were recovered in 7 (64%) of the outbreaks. Multiple pathogens were identified in 3 outbreaks. The most frequently identified pathogen in stools was Giardia lamblia which was recovered in 5 (45%) of the outbreaks. Ten of the 11 (91%) outbreaks occurred in children less than 12 months of age.^ Environmental microbiology studies together with epidemiologic information revealed that enteric organisms were transmitted from person-to-person. On routine sampling, fecal coliforms were most frequently isolated from tap handles and diaper change areas. Contamination with fetal coliforms was wide-spread during diarrhea outbreaks. Fecal coliforms were recovered with significantly greater frequency from hands, toys and other classroom objects during outbreaks than during non-outbreak period. Salmonella typhimurium was recovered from a table top during an outbreak of Salmonellosis. There was no association between the level of enteric microbial contamination in the toilet areas and the occurrence of outbreaks. No evidence was found to indicate that enteric organisms were spread by the airborne route via aerosols.^ Toys, other classroom objects and contaminated hands probably play a major role in the transmission of enteropathogens during day-care center outbreaks. The presence of many enteric agents in the environment undoubtedly explains the polymicrobial etiology of the day-care center associated diarrhea outbreaks. ^
Resumo:
Understanding the origins, transport and fate of contamination is essential to effective management of water resources and public health. Individuals and organizations with management responsibilities need to understand the risks to ecosystems and to humans from contact with contamination. Managers also need to understand how key contaminants vary over time and space in order to design and prioritize mitigation strategies. Tumacacori National Historic Park (NHP) is responsible for management of its water resources for the benefit of the park and for the health of its visitors. The existence of microbial contaminants in the park poses risks that must be considered in park planning and operations. The water quality laboratory at the Maricopa Agricultural Center (in collaboration with stakeholder groups and individuals located in the ADEQ-targeted watersheds) identified biological changes in surface water quality in impaired reaches rivers to determine the sources of Escherichia coli (E. coli); bacteria utilizing innovative water quality microbial/bacterial source tracking methods. The end goal was to support targeted watershed groups and ADEQ towards E. coli reductions. In the field monitoring was conducted by the selected targeted watershed groups in conjunction with The University of Arizona Maricopa Agricultural Center Water Quality Laboratory. This consisted of collecting samples for Bacteroides testing from multiple locations on select impaired reaches, to determine contamination resulting from cattle, human recreation, and other contributions. Such testing was performed in conjunction with high flow and base flow conditions in order to accurately portray water quality conditions and variations. Microbial monitoring was conducted by The University of Arizona Water Quality Laboratory at the Maricopa Agricultural Center using genetic typing to differentiate among two categories of Bacteroides: human and all (total). Testing used microbial detection methodologies and molecular source tracking techniques.^