4 resultados para SUBTOTAL HYSTERECTOMY

em DigitalCommons@The Texas Medical Center


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We sought to determine maternal and neonatal outcomes by labor onset type and gestational age. STUDY DESIGN: We used electronic medical records data from 10 US institutions in the Consortium on Safe Labor on 115,528 deliveries from 2002 through 2008. Deliveries were divided by labor onset type (spontaneous, elective induction, indicated induction, unlabored cesarean). Neonatal and maternal outcomes were calculated by labor onset type and gestational age. RESULTS: Neonatal intensive care unit admissions and sepsis improved with each week of gestational age until 39 weeks (P < .001). After adjusting for complications, elective induction of labor was associated with a lower risk of ventilator use (odds ratio [OR], 0.38; 95% confidence interval [CI], 0.28-0.53), sepsis (OR, 0.36; 95% CI, 0.26-0.49), and neonatal intensive care unit admissions (OR, 0.52; 95% CI, 0.48-0.57) compared to spontaneous labor. The relative risk of hysterectomy at term was 3.21 (95% CI, 1.08-9.54) with elective induction, 1.16 (95% CI, 0.24-5.58) with indicated induction, and 6.57 (95% CI, 1.78-24.30) with cesarean without labor compared to spontaneous labor. CONCLUSION: Some neonatal outcomes improved until 39 weeks. Babies born with elective induction are associated with better neonatal outcomes compared to spontaneous labor. Elective induction may be associated with an increased hysterectomy risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To assess differences in body weight, body composition, total cholesterol, blood pressure, and blood glucose between OC users and non-users age 18-30 y before and after a 15-week cardiovascular exercise program in Houston, TX from 2003 to 2007.^ Study Design. Secondary analysis of prospective data. ^ Study Subjects. 453 Non-Hispanic white (NHW), Hispanic, and African American (AA) women age 18-30 y with no previous live birth, a history of menstruating, no use of other hormonal contraceptives or medications, no menopause or hysterectomy, and no current pregnancies.^ Measurements. Demographic data, medication use, and menstrual history were assessed via self-administered questionnaires at baseline. Anthropometric and laboratory measures were taken at baseline and 15-weeks. ^ Data Analysis. Linear regression assessed the association between OC use and study variables at baseline, and the change in study variables from baseline to 15-weeks. Logistic regression assessed the association between OC use and CVD risk. Each analysis was also stratified by race/ethnicity. ^ Results. At baseline, OC users had higher total cholesterol (p<.0005) and were above cholesterol risk cut points for CVD (OR=4.3, 95% CI=2.4-7.7) compared to non-users. At baseline, OC use was also associated with higher diastolic blood pressure (p=.018) compared to non-users, primarily in non-Hispanic whites (p=.007). OC use was associated with lower blood glucose compared to non-users in Hispanics only (p=.008). OC use was associated with absolute change in diastolic blood pressure (p=.044) and total cholesterol (p=.003). There was evidence that OC use may affect individuals differently based on race/ethnicity for certain obesity and CVD risk factors.^ Conclusions. OC users and non-users responded similarly to a 15-week cardiovascular exercise program. Exceptions included a greater change in diastolic blood pressure and total cholesterol among NHW and Hispanic OC users compared to non-users after exercise intervention. At baseline, OC use was associated with diastolic blood pressure and was most strongly associated with increased levels of total cholesterol. OC users were at greater risk of having total cholesterol above CVD risk cut points than non-users.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. We performed a case-comparison study to describe the characteristics of LUS tumors and their association with risk factors for endometrial cancer. ^ Patients and Methods. From January 1996 through October 2007, 3,892 women were identified with a diagnosis of primary endometrial carcinoma or primary cervical adenocarcinoma. Pathology records from the 1,009 women who had a hysterectomy were reviewed. Subjects were included in the LUS group only if the tumor was clearly originating from the area between the lower corpus and upper cervix in the hysterectomy specimen. The LUS group was compared to all patients with endometrial corpus carcinoma who underwent hysterectomy at our institution in a 12-month period randomly selected from the study period. Risk factors for endometrial carcinoma such as body mass index (BMI) and Lynch Syndrome were assessed. Expression of estrogen receptor (ER), vimentin, carcinoembryonic antigen (CEA), p16, and human papilloma virus DNA (HPV DNA) was assessed; this panel is known to be effective in distinguishing adenocarcinomas of endometrial versus endocervical origin. Fisher's Exact, Chi-square, Mann-Whitney, and Student's t-tests were utilized for statistical analysis. ^ Results. Thirty-five of 1,009 women had endometrial carcinoma of the LUS (3.5%; 95% CI: 2–4%). Compared to patients with corpus tumors, LUS patients were younger (54.2 vs. 62.9 years, P = .001), had higher stage (P < .001), and more invasive tumors (P = .001). Preoperative diagnosis of the LUS tumors more frequently included the possibility of endocervical adenocarcinoma ( P < .001), leading to preoperative radiation therapy in 4 patients. Median BMI was similar in the LUS and corpus groups. Seventy-three percent of the available LUS tumors had a similar immunohistochemical expression pattern to conventional endometrioid adenocarcinoma. Because of the young median age for the LUS group, we performed immunohistochemistry for Lynch syndrome-associated DNA mismatch repair proteins MLH1, MSH2, MSH6, and PMS2. Microsatellite instability testing (MSI) and MLH1 promoter hypermethylation were performed when indicated. Thirty-six percent of the LUS tumors were MSI-high. Ten of thirty-five (29%) women with LUS tumors were either confirmed to have Lynch Syndrome or were strongly suspected to have Lynch Syndrome based on tissue-based molecular assays (95% CI, 16 to 45%). ^ Conclusions. Endometrial carcinoma arising in the LUS is a clinical and pathologic entity which can be diagnostically confused with cervical adenocarcinoma. In general, LUS tumors can be correctly identified as being endometrial carcinoma using the immunohistochemical panel noted above. The prevalence of Lynch Syndrome in patients with LUS tumors is much greater than that of the general endometrial cancer population (1.8%) or in endometrial cancer patients younger than 50 years of age (8–9%). Based on our results, the possibility of Lynch Syndrome should be considered in women with LUS tumors. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Section "A": Dissecting and Post-Mortem Instruments Diagnostic Instruments and Apparatus Microscopes and Microscopic Accessories Laboratory Apparatus and Glass Ware Apparatus for Blood and Urine Analysis Apparatus for Phlebotomy, Cupping and Leeching Apparatus for Infusion and Transfusion Syringes for Aspiration and Injection Osteological Preparations Section "B": Anaesthetic, General Operating, Osteotomy, Trepanning, Bullet, Pocket Case, Cautery, Ligatures, Sutures, Dressings, Etc. Section "B" continued Section "C": Eye, Ear, Nasal, Dermal, Oral, Tonsil, Tracheal, Laryngeal,Esophageal, Stomach, Intestinal, Gall Bladder Section "C": continued Section "D": Rectal, Phimosis, Prostatic, Vesical, Urethral, Ureteral, Instruments Section "E": Gynecic, Hysterectomy, Obstetrical, Instrument Satchels, Medicine Cases Section "F": Electric Cautery Transformers, Electro-Cautery Burners and Accessories, Electric Current Controllers, Electro-Diagnostic Outfits, Electrolysis Instruments Electro-Therapeutic Lamps, Faradic Batteries, Galvanic Batteries Section "G": Office Furniture, Office Sterilizing Apparatus, Hospital Supplies, Surgical Rubber Goods, Sick Room Utensils, Invalid Rolling Chairs, Invalid Supplies Section "H": Artificial Limbs, Deformity Apparatus, Fracture Apparatus, Splints, Splint Material, Elastic Hosiery, Abdominal Supporters, Crutches, Trusses, Suspensories, Etc. Index