3 resultados para STIFFLY-STABLE METHODS
em DigitalCommons@The Texas Medical Center
Resumo:
Aim. To review and explore cataract prevalence in stable and unstable countries by examining published and unpublished ocular literature about Africa from 1980 onwards.^ Methods. Searches using OVID, Proquest Dissertations, WHO, and Ebsco Host were done. The review was restricted to articles utilizing WHO definitions of blindness and low vision. Random cluster sampling technique with a minimum sample size of 1,500, and reporting causes of blindness categorized by age and gender were inclusion considerations in the selected articles. ^ Results. Blindness and low vision increased with conflict. Women and the elderly were more likely to have vision impairing cataract. Cataract was the leading cause of blindness; the prevalence range was 22%–81% for the reviewed nations.^ Conclusion. Instability was connected to higher cataract prevalence and worse visual outcome across all characteristics examined except cataract surgical rates. ^
Resumo:
Developing countries are heavily burdened by limited access to safe drinking water and subsequent water-related diseases. Numerous water treatment interventions combat this public health crisis, encompassing both traditional and less-common methods. Of these, water disinfection serves as an important means to provide safe drinking water. Existing literature discusses a wide range of traditional treatment options and encourages the use of multi-barrier approaches including coagulation-flocculation, filtration, and disinfection. Most sources do not delve into approaches specifically appropriate for developing countries, nor do they exclusively examine water disinfection methods.^ The objective of this review is to focus on an extensive range of chemical, physio-chemical, and physical water disinfection techniques to provide a compilation, description and evaluation of options available. Such an objective provides further understanding and knowledge to better inform water treatment interventions and explores alternate means of water disinfection appropriate for developing countries. Appropriateness for developing countries corresponds to the effectiveness of an available, easy to use disinfection technique at providing safe drinking water at a low cost.^ Among chemical disinfectants, SWS sodium hypochlorite solution is preferred over sodium hypochlorite bleach due to consistent concentrations. Tablet forms are highly recommended chemical disinfectants because they are effective and very easy to use, but also because they are stable. Examples include sodium dichloroisocyanurate, calcium hypochlorite, and chlorine dioxide, which vary in cost depending on location and availability. Among physio-chemical disinfection options, electrolysis which produces mixed oxidants (MIOX) provides a highly effective disinfection option with a higher upfront cost but very low cost over the long term. Among physical disinfection options, solar disinfection (SODIS) applications are effective, but they treat only a fixed volume of water at a time. They come with higher initial costs but very low on-going costs. Additional effective disinfection techniques may be suitable depending on the location, availability and cost.^
Resumo:
Species variations in formaldehyde solutions and gases were investigated by means of infrared spectral analysis. Double beam infrared spectrometry in conjunction with sodium chloride wafer technique and solvent compensation technique were employed. Formaldehyde species in various solutions were investigated. Formalin 37% was stable for many months. Refrigeration had no effects on its stability. Spectral changes were detected in 1000 ppm formaldehyde solutions. The absorbances of very diluted solutions up to 100 ppm were lower than the detection limit of the instruments. Solvent compensation improved resolution, but was associated with an observed lack of repeatability. Formaldehyde species in animal chambers containing animals and in mobile home air were analyzed with the infrared spectrophotometer equipped with a 10 cm gas cell. Spectra were not different from the spectrum of clean air. A portable single beam infrared spectrometer with a 20 meter pathlength was used for reinvestigation. Indoor formaldehyde could not be detected in the spectral; conversely, an absorption peak at 3.58 microns was found in the spectra of 3 and 15 ppm formaldehyde gas in animal chambers. This peak did not appear in the spectrum of the control chamber. Because of concerns over measurement bias among various analytical methods for formaldehyde, side-by-side comparisons were conducted in both laboratory and field measurements. The chromotropic acid method with water and 1% sodium bisulfite as collection media, the pararosaniline method, and a single beam infrared spectrometer were compared. Measurement bias was elucidated and the extent of the effects of temperature and humidity was also determined. The problems associated with related methods were discussed. ^