5 resultados para Reverse discrimination
em DigitalCommons@The Texas Medical Center
Resumo:
Perceptual learning is a training induced improvement in performance. Mechanisms underlying the perceptual learning of depth discrimination in dynamic random dot stereograms were examined by assessing stereothresholds as a function of decorrelation. The inflection point of the decorrelation function was defined as the level of decorrelation corresponding to 1.4 times the threshold when decorrelation is 0%. In general, stereothresholds increased with increasing decorrelation. Following training, stereothresholds and standard errors of measurement decreased systematically for all tested decorrelation values. Post training decorrelation functions were reduced by a multiplicative constant (approximately 5), exhibiting changes in stereothresholds without changes in the inflection points. Disparity energy model simulations indicate that a post-training reduction in neuronal noise can sufficiently account for the perceptual learning effects. In two subjects, learning effects were retained over a period of six months, which may have application for training stereo deficient subjects.
Resumo:
Aminoacyl-tRNA synthetases (RSs) are responsible for the essential connection of amino acids with trinucleotide sequences of tRNA's. The RS family constitutes two structurally dissimilar groups of proteins, class I and class II. Methionyl-tRNA synthetase (MetRS) and isoleucyl-tRNA synthetase (IleRS), both members of class I, were the focus of this work. Both enzymes are zinc-containing proteins; show a high degree of amino acid specificity; and edit activated noncognate amino acids, thereby ensuring the fidelity of the genetic code. The goals of this work were to further delineate the molecular basis of catalysis and discrimination in these enzymes by mapping active site geometries using high-resolution nuclear magnetic resonance spectroscopy (NMR).^ Internuclear distances obtained from transferred nuclear Overhauser effects were used to define the conformations of Mg($\alpha$,$\beta$-methylene)ATP bound to E. coli MetRS and E. coli IleRS in multiple complexes. Identical conformations were found for the bound ATP. Thus, the predicted structural homology between IleRS and MetRS is supported by consensus enzyme-bound nucleotide conformations. The conformation of the bound nucleotide is not sensitive to occupation of the amino acid site of MetRS or IleRS. Therefore, conformational changes known to occur in the synthetases upon ligand binding appear not to alter the bound conformation of the adenosine portion of the nucleotide. Nuclear Overhauser effects on the substrate amino acid L-selenomethionine were also used to evaluate the enzyme-bound conformation of the cognate amino acid. The amino acid assumes a conformation which is consistent with a proposed editing mechanism.^ The E. coli MetRS was shown to catalyze amino acid $\alpha$-proton exchange in the presence of deuterium oxide of all cognate amino acids. It is proposed that the enzyme-bound zinc coordinates the $\alpha$-carboxylate of the amino acid, rendering the $\alpha$-proton more acidic. An enzymic base is responsible for exchange of the $\alpha$-proton. This proposal suggests that the enzyme-bound zinc may have a role in amino acid discrimination in MetRS. However, the role of this exchange reaction in catalysis remains unknown. ^
Resumo:
Objective. Itraconazole is recommended life-long for preventing relapse of disseminated histoplasmosis in HIV-infected patients. I sought to determine if serum itraconazole levels are affected by the type of Highly Active Anti-Retroviral Therapy (NNRTI or PI) being taken concomitantly to treat HIV. ^ Design. Retrospective cohort. ^ Methods. De-identified data were used from an IRB-approved parent study which identified patients on HAART and maintenance itraconazole for confirmed disseminated histoplasmosis between January 2003 and December 2006. Available itraconazole blood levels were abstracted as well as medications taken by each patient at the time of the blood tests. Mean itraconazole levels were compared using the student's t-test. ^ Results. 11 patients met study criteria. Patient characteristics were: median age 36, 91% men, 18% white, 18% black, 55% Hispanic and 9% Asians, median CD4 cell count 120 cells/mm3. 14 blood levels were available for analysis—8 on PI, 4 on NNRTI and 2 on both. 8/8 itraconazole levels obtained while taking concomitant PI were therapeutic (>0.4 μg/mL) in contrast to 0/4 obtained while taking NNRTI. Two patients switched from NNRTI to PI and reached therapeutic levels. Mean levels on NNRTI (0.05 μg/mL, s.d. 0.0) and on PI (2.45 μg/mL, s.d. 0.21) for these two patients were compared via a paired t-test (t = 16.00, d.f. = 1, P = 0.04). Remaining patient levels were compared using an unpaired t-test. Mean itraconazole on concomitant PI (n = 6) was 1.37 μg/mL (s.d. 0.74), while the mean on concomitant NNRTI was 0.05 μg/mL (s.d. 0.0), t = 2.39, d.f. = 6, P = 0.05. ^ Conclusions. Co-administration of NNRTI and itraconazole results in significant decreases in itraconazole blood levels, likely by inducing the CYP3A4 enzyme system. Itraconazole drug levels should be monitored in patients on concomitant NNRTI. PI-based HAART may be preferred over NNRTI-based HAART when using itraconazole to treat HIV-infected patients with disseminated histoplasmosis. ^
Resumo:
A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using $\alpha$/$\beta$ discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen.^ U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-$\ell$ aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi $\ell\sp{-1}$. $\alpha$-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi $\ell\sp-1$ are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain $\sp{234}$U/$\sp{238}$U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation.^ The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross $\alpha$ activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi $\ell\sp{-1}$, with seven samples exceeding the proposed Maximum Contaminant Level of 20 $\mu$g $\ell\sp{-1}$. Four exceeded the proposed activity screening level of 30 pCi $\ell\sp{-1}$. Isotopic ratios ranged from 0.87 to 41.8, while one sample contained $\sp{234}$U activity of 34.6 pCi $\ell\sp{-1}$ in the complete absence of its parent, $\sp{238}$U. U mass in the samples with elevated activity ranged from 0.0 to 103 $\mu$g $\ell\sp{-1}$. A limited test of screening surface and groundwaters for contamination by U from waste sites and natural processes was also successful. ^