2 resultados para Reflectors (Safety devices)

em DigitalCommons@The Texas Medical Center


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study has the purpose of determining the barriers and facilitators to nurses' acceptance of the Johnson and Johnson Protectiv®* Plus IV catheter safety needle device and implications for needlestick injuries at St. Luke's Episcopal Hospital, Houston, Texas. A one-time cross-sectional survey of 620 responding nurses was conducted by this researcher during December, 2000. The study objectives were to: (1) describe the perceived (a) organizational and individual barriers and facilitators and (b) acceptance of implementation of the IV catheter device; (2) examine the relative importance of these predictors; (3) describe (a) perceived changes in needlestick injuries after implementation of the device; (b) the reported incidence of injuries; and (c) the extent of underreporting by nurses; and (4) examine the relative importance of (a) the preceding predictors and (b) acceptance of the device in predicting perceived changes in needlestick injuries. Safety climate and training were evaluated as organizational factors. Individual factors evaluated were experience with the device, including time using it and frequency of use, and background information, including nursing unit, and length of time as a nurse in this hospital and in total nursing career. The conceptual framework was based upon the safety climate model. Descriptive statistics and multiple and logistic regression were utilized to address the study objectives. ^ The findings showed widespread acceptance of the device and a strong perception that it reduced the number of needlesticks. Acceptance was notably predicted by adequate training, appropriate time between training and device use, solid safety climate, and short length of service, in that order. A barrier to acceptance was nurses' longtime of use of previous needle technologies. Over four-fifths of nurses were compliant in always using the device. Compliance had two facilitators: length of time using device and, to a lesser extent, safety climate. Rates of compliance tended to be lower among nurses in units in which the device was frequently used. ^ High quality training and an atmosphere of caring about nurse safety stand out as primary facilitators that other institutions would need to adopt in order to achieve maximum success in implementing safety programs involving utilization of new safety devices. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Birth defects occur in 1 of every 33 babies born in the United States, and are the leading cause of infant death. Mothers using contraceptives that become pregnant may continue to use their contraceptives after their first missed menstrual period, thus exposing their baby in utero to the contraceptive product. Progesterone is also sometimes prescribed during the first trimester of pregnancy to mothers with a history of miscarriages or infertility problems. To ensure the safety of these products, it is important to investigate whether there is an increased occurrence of babies born with birth defects to mothers using various contraceptive methods or progesterone in early pregnancy. Using data from the National Birth Defects Prevention Study (NBDPS), an ongoing multi-state, population based case-control study, this study assessed maternal exposures to IUDs, spermicides, condoms and progesterone in early pregnancy. ^ Progesterone used for threatened miscarriage during the first three months of pregnancy was associated with an increased occurrence of hypoplastic left heart (adjusted odds ratios (OR) 2.24, 95% CI 1.13-4.21), perimembranous ventricular septal defects (OR 1.64, 95% CI 1.10-2.41), septal associations (OR 2.52, 95% CI 1.45-4.24), esophageal atresia (OR 1.82, 95% CI 1.04-3.08), and hypospadias (OR 2.12, 95% CI 1.41-3.18). Mothers using progesterone for injectable contraception had increased (OR > 2.5), but insignificant odds ratios for anencephaly, septal associations, small intestinal atresias and omphalocel. Progesterone used for fertility was not associated with an increased occurrence of any birth defects examined. ^ Mothers using progesterone for fertility assistance and threatened miscarriage were very similar with respect to their demographics and pregnancy history. They also both reported similar types of progesterone. Thus, if progesterone was a causal risk factor for birth defects we would have expected to observe similar increases in risk among mothers using progesterone for both indications. Because we predominantly observed increased associations among mothers using progesterone for threatened miscarriage but not fertility assistance, it is possible the increased associations we observed were confounded by indication (i.e. progesterone was administered for vaginal bleeding which occurred as a sequelae to the formation of a congenital anomaly. ^ No significant increased associations were observed between maternal spermicide use during pregnancy and 26 of 27 types of structural malformations. While multiple statistical tests were performed we observed first trimester maternal spermicide use to be associated with a significant increased occurrence of perimembranous ventricular septal defects (OR 2.21, 95% CI 1.16-4.21). A decreased occurrence (OR < 1.0) was observed for several categories of birth defects among mothers who conceived in the first cycle after discontinuing the use of spermicides (22 of 28) or male condoms (23 of 33). ^ Overall the percent of IUD use was similar between mothers of controls and mothers of all cases in aggregate (crude OR 1.05, 95% CI 0.61-1.84). Power was limited to detect significant associations between IUD use and birth defects, however mothers using an IUD in the month immediately prior to conception or during pregnancy were not associated with an increase of birth defects. Limb defects and amniotic band sequence previously reported to be associated with IUD use during pregnancy were not found to occur among any mothers reporting the use of an IUD during pregnancy.^