7 resultados para Readings and recitations.
em DigitalCommons@The Texas Medical Center
Resumo:
Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^
Resumo:
Background. Necrotizing pneumonia is generally considered a rare complication of pneumococcal pneumonia in adults. We systematically studied the incidence of necrotizing changes in adult patients with pneumococcal pneumonia, and examined the severity of infection, the role of causative serotype and the association with bacteremia. ^ Methods. We used a data base of all pneumococcal infections identified at our medical center between 2000 and 2010. Original readings of chest X-rays (CXR) and computerized tomography (CT) were noted. All images were then reread independently by 2 radiologists. The severity of disease was assessed using the SMART-COP scoring system. ^ Results. There were 351 cases of pneumococcal pneumonia. Necrosis was reported in no original CXR readings and 6 of 136 (4.4%) CTs. With re-reading, 8 of 351 (2.3%) CXR and 15 of 136 (11.0%) CT had necrotizing changes. Overall, these changes were found in 23 of 351 (6.6%, 95% CI 4.0 - 9.1) patients. The incidence of bacteremia and the admitting SMART-COP scores were similar in patients with and without necrosis (P=1.00 and P=0.32, respectively). Type 3 pneumococcus was more commonly isolated from patients with than from patients without necrotizing pneumonia (P=0.05), but a total of 10 serotypes were identified among 16 cases in which the organism was available for typing. ^ Conclusions. Necrotizing changes in the lungs were seen in 6.6% (95% CI 4.0 - 9.1) of a large series of adults with pneumococcal pneumonia. Patients with necrosis were not more likely to have bacteremia or more severe disease. Type 3 pneumococcus was commonly implicated, but 9 other serotypes were also identified.^
Resumo:
The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.
Resumo:
With the development of the water calorimeter direct measurement of absorbed dose in water becomes possible. This could lead to the establishment of an absorbed dose rather than an exposure related standard for ionization chambers for high energy electrons and photons. In changing to an absorbed dose standard it is necessary to investigate the effect of different parameters, among which are the energy dependence, the air volume, wall thickness and material of the chamber. The effect of these parameters is experimentally studied and presented for several commercially available chambers and one experimental chamber, for photons up to 25 MV and electrons up to 20 MeV, using a water calorimeter as the absorbed dose standard and the most recent formalism to calculate the absorbed dose with ion chambers.^ For electron beams, the dose measured with the calorimeter was 1% lower than the dose calculated with the chambers, independent of beam energy and chamber.^ For photon beams, the absorbed dose measured with the calorimeter was 3.8% higher than the absorbed dose calculated from the chamber readings. Such differences were found to be chamber and energy independent.^ The results for the photons were found to be statistically different from the results with the electron beams. Such difference could not be attributed to a difference in the calorimeter response. ^
Resumo:
Background. Ambulatory blood pressure (ABP) measurement is a means of monitoring cardiac function in a noninvasive way, but little is known about ABP in heart failure (HF) patients. Blood pressure (BP) declines during sleep as protection from consistent BP load, a phenomenon termed "dipping." The aims of this study were (1) to compare BP dipping and physical activity between two groups of HF patients with different functional statuses and (2) to determine whether the strength of the association between ambulatory BP and PA is different between these two different functional statuses of HF. ^ Methods. This observational study used repeated measures of ABP and PA over a 24-hour period to investigate the profiles of BP and PA in community-based individuals with HF. ABP was measured every 30 minutes by using a SpaceLabs 90207, and a Basic Motionlogger actigraph was used to measure PA minute by minute. Fifty-six participants completed both BP and physical activity for a 24-hour monitoring period. Functional status was based on New York Heart Association (NYHA) ratings. There were 27 patients with no limitation of PA (NYHA class I HF) and 29 with some limitation of PA but no discomfort at rest (NYHA class II or III HF). The sample consisted of 26 men and 30 women, aged 45 to 91 years (66.96 ± 12.35). ^ Results. Patients with NYHA class I HF had significantly greater dipping percent than those with NYHA class II/III HF after controlling their left ventricular ejection fraction (LVEF). In a mixed model analysis (PROC MIXED, SAS Institute, v 9.1), PA was significantly related to ambulatory systolic and diastolic BP and mean arterial pressure. The strength of the association between PA and ABP readings was not significantly different for the two groups of patients. ^ Conclusions. These preliminary findings demonstrate differences between NYHA class I and class II/III of HF in BP dipping status and ABP but not PA. Longitudinal research is recommended to improve understanding of the influence of disease progression on changes in 24-hour physical activity and BP profiles of this patient population. ^ Key Words. Ambulatory Blood Pressure; Blood Pressure Dipping; Heart Failure; Physical Activity. ^
Resumo:
Context. Despite the rapid growth of disease management programs, there are still questions about their efficacy and effectiveness for improving patient outcomes and their ability to reduce costs associated with chronic disease. ^ Objective. To determine the effectiveness of disease management programs on improving the results of HbA1c tests, lipid profiles and systolic blood pressure (SBP) readings among diabetics. These three quantitative measures are widely accepted methods of determining the quality of a patient's diabetes management and the potential for future complications. ^ Data Sources. MEDLINE and CINAHL were searched from 1950 to June 2008 using MeSH terms designed to capture all relevant studies. Scopus pearling and hand searching were also done. Only English language articles were selected. ^ Study Selection. Titles and abstracts for the 2347 articles were screened against predetermined inclusion and exclusion criteria, yielding 217 articles for full screening. After full article screening, 29 studies were selected for inclusion in the review. ^ Data Extraction. From the selected studies, data extraction included sample size, mean change over baseline, and standard deviation for each control and experimental arm. ^ Results. The pooled results show a mean HbA1c reduction of 0.64%, 95% CI (-0.83 to -0.44), mean SBP reduction of 7.39 mmHg (95% CI to -11.58 to -3.2), mean total cholesterol reduction of 5.74 mg/dL (95% CI, -10.01 to -1.43), and mean LDL cholesterol reduction of 3.74 mg/dL (95% CI, -8.34 to 0.87). Results for HbA1c, SBP and total cholesterol were statistically significant, while the results for LDL cholesterol were not. ^ Conclusions. The findings suggest that disease management programs utilizing five hallmarks of care can be effective at improving intermediate outcomes among diabetics. However, given the significant heterogeneity present, there may be fundamental differences with respect to study-specific interventions and populations that render them inappropriate for meta-analysis. ^
Resumo:
Physical activity is a key component of life-style modification process which helps to reduce the risk of developing chronic diseases. It is important to have accurate estimates of physical activity to identify sedentary populations where interventions might be helpful. The International Physical Activity Questionnaire (IPAQ) short version has been used to estimate physical activity in diverse populations. However, there is little literature depicting the use of the IPAQ short version in Mexican America population. This study addressed the predictive validity and test-retest reliability of the IPAQ short version in Mexican American adults. The analysis was performed on 97 participants enrolled in the Cameron County Hispanic Cohort. Individuals selected in this study were 18 years of age or older. The predictive validity was evaluated by studying the relationship between physical activity and biomarkers known to be correlated with physical activity, namely, TNF-α, Adiponectin, and HDL. Multiple linear regression analysis was performed to delineate predictive validity. To assess test-retest reliability, two IPAQ-short last seven days questionnaires were interviewer administered to the participants on the same day, approximately two hours apart. Test-Retest reliability of IPAQ was estimated by performing intraclass correlations between the readings at two different time periods. The study showed that the IPAQ – short version used in the above study had acceptable test-retest reliability in the Mexican American population. This study showed that the IPAQ – short version did not have acceptable predictive validity when looking at physical activity and TNF-α, Adiponectin, and HDL in this sample.^